The non-pure beta(+)-emitting iodine-isotope I-120 is potentially a short-lived alternative to I-124 for PET imaging. I-120 has a half-life of 81 min and a maximum beta(+)-energy of 4 MeV. Literature data on beta(+)-abundance are rather uncertain. This study evaluates parameters important for PET imaging of I-120 and characterizes PET measurements using this isotope. I-120 was produced via the Te-122(p,3n) and Te-120(p,n) reactions, the latter of which led to only very small impurities of I-120m and I-119. PET measurements were done with a brain-slice shaped phantom consisting of a gray (GM) and a white matter (WM) chamber. A 1mm line source positioned in the occipital part of this phantom was filled with I-120 or F-18. Comparative studies using the Hoffman 3D-brain phantom were done with I-120, F-18, I-124, and I-123 (measured with SPECT). The measurements were evaluated with respect to the half-life, beta(+)-abundance, image resolution and GM/WM contrast. For all measurements reported here the 2D PET-scanner GE PC4096+ was used. The measured half-life was 82.4min, and the beta(+)-abundance 52 +/- 5%. The reconstructed image resolution was 9.7 mm FWHM compared to 7.5 mm when F-18 was used. The GM/WM contrast was underestimated by about 10%. Images of the brain phantom revealed an image quality inferior to that when F-18 or I-124 was applied, but better than the I-123-SPECT image. Our data show that I-120 of high radionuclidic purity produced by the Te-120(p,n) reaction can be regarded as a suitable radionuclide for the PET-imaging of iodine-labeled radiopharmaceuticals.
引用
收藏
页码:2245 / 2247
页数:3
相关论文
共 33 条
  • [21] Short-lived positron emitters in beam-on PET imaging during proton therapy (vol 60, 8923, 2015)
    Dendooven, P.
    Buitenhuis, H. J. T.
    Diblen, F.
    Heeres, P. N.
    Biegun, A. K.
    Fiedler, F.
    van Goethem, M-J
    van der Graaf, E. R.
    Brandenburg, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [22] Isotopic labeling with short-lived radionuclides represents the future for clinical PET imaging
    Harkness, B
    Madsen, MT
    Hendee, WR
    MEDICAL PHYSICS, 2002, 29 (12) : 2897 - 2899
  • [23] TRANSPORTATION OF SHORT-LIVED POSITRON EMITTERS FROM A MEDICAL CYCLOTRON TO A REMOTE IMAGING SUITE
    CORREIA, JA
    BUCELEWICZ, WH
    STRAUSS, HW
    ALPERT, NM
    BROWNELL, GL
    TAVERAS, JM
    MEDICAL PHYSICS, 1983, 10 (02) : 228 - 231
  • [24] Radiolabeling of multimeric neurotensin(8-13) analogs with the short-lived positron emitter fluorine-18
    Hultsch, Christina
    Berndt, Mathias
    Bergmann, Ralf
    Wuest, Frank
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (07) : 818 - 826
  • [25] 122Xe/122I Generator development: Short-lived PET isotope availability
    O'Neil, James P.
    Buddinger, Thomas F.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [26] NEMA NU 2-2007 Measurements and GATE Monte Carlo Simulations of GE Signa integrated PET/MR for Pure and Non-Pure Positron Emitters
    Caribe, P. R. R. V.
    Koole, M.
    Diogo, A.
    D'Asseler, Y.
    Deller, T.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S352 - S353
  • [27] DOUBLE-TRACER TECHNIQUE FOR QUANTITATIVE AUTORADIOGRAPHY WITH SHORT-LIVED POSITRON EMITTERS USING A BIO IMAGING ANALYZER SYSTEM
    Noguchi, J.
    Zhang, M. -R.
    Suzuki, K.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2005, 48 : S143 - S143
  • [28] FROM I-131 TO SHORT-LIVED POSITRON EMITTERS IN NUCLEAR-MEDICINE - CHANGING PERSPECTIVES IN RADIONUCLIDE USE
    WOLF, AP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 43 - NUCL
  • [29] Expanding the scope of carbon-11 labelled ureas: A universal method to access short-lived click reagents for in vivo PET imaging
    Bongarzone, Salvatore
    Ferocino, Alessandra
    Gee, Antony
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2019, 62 : S244 - S245
  • [30] Tumor imaging with PET using the short-lived praseodymium-140 from the 140Nd /140Pr in vivo generator
    Zeisler, SK
    Becker, DW
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ISOTOPES: ISOTOPE PRODUCTION AND APPLICATIONS IN THE 21ST CENTURY, 2000, : 430 - 432