Benchtop and Handheld Energy-Dispersive X-Ray Fluorescence (EDXRF) as Alternative for Selenium Concentration Measurement in Biofortified Broccoli Seedling

被引:7
|
作者
Bachiega, Patricia [1 ]
de Almeida, Eduardo [2 ]
Salgado, Jocelem Mastrodi [1 ]
Zezzi Arruda, Marco Aurelio [3 ,4 ]
Lehmann, Eraldo Luiz [3 ,4 ]
Morzelle, Maressa Caldeira [5 ]
Pereira de Carvalho, Hudson Wallace [2 ]
机构
[1] Univ Sao Paulo, Esalq, Escola Super Agr Luiz de Queiroz, Dept Agroind Alimentos & Nutr, Ave Padua Dias 111, BR-13418900 Piracicaba, SP, Brazil
[2] Univ Sao Paulo, CENA, LIN, BR-13416000 Piracicaba, Brazil
[3] Univ Estadual Campinas, UNICAMP, GEPAM, Dept Quim Analit,Inst Quim, POB 6154, BR-13083970 Campinas, SP, Brazil
[4] Univ Estadual Campinas, UNICAMP, Inst Quim, Inst Nacl Ciencia & Tecnol Bioanalit, BR-13083970 Campinas, SP, Brazil
[5] Univ Fed Mato Grosso, FANUT, UFMT, Dept Alimentos Nutr,Fac Nutr, Rua Fernando Correa Costa 2367, BR-78060900 Cuiaba, MT, Brazil
基金
巴西圣保罗研究基金会;
关键词
Brassica oleracea; X-ray fluorescence; Complex matrices; Biofortification; Leaves; Selenium; SUPPLEMENTATION; SPECTROMETRY; PERFORMANCE; ENVIRONMENT; METABOLISM; RICE; PXRF;
D O I
10.1007/s12161-019-01489-5
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Biofortification of crops with selenium (Se) is an effective strategy to increase the consumption of this micronutrient. Inductively coupled plasma mass spectrometry (ICP-MS) is one of the most used techniques in quantifying Se. However, due to some disadvantages (high cost, long analysis time, and being destructive), there is a need for new alternatives to Se quantification. This study aimed at establishing instrumental parameters for Se quantification, using two energy-dispersive X-ray fluorescence spectrometry (EDXRF) techniques (benchtop and handheld) in Se-biofortified broccoli seedlings and comparing it with ICP-MS. The results showed that the selection of proper filters for both EDXRF systems was crucial for determining Se and, when compared with ICP-MS, presented similar results for selenium-biofortified broccoli seedling treatments (BS50Se). In addition, the EDXRF techniques presented a Se limit of detection (LOD) at 0.6-0.9mgkg(-1). This study demonstrates that EDXRF systems were successfully applied to concentration measurement of Se in biofortified samples and linked to low cost and shorter analysis time.
引用
收藏
页码:1520 / 1527
页数:8
相关论文
共 50 条
  • [31] Combining CdTe and Si detectors for Energy-Dispersive X-Ray Fluorescence
    Redus, R.
    Huber, A.
    Pantazis, T.
    Pantazis, J.
    Cross, B.
    X-RAY SPECTROMETRY, 2012, 41 (06) : 393 - 400
  • [32] Impact of Soil Water on the Spectral Characteristics and Accuracy of Energy-Dispersive X-ray Fluorescence Measurement
    Gu, Runyao
    Lei, Mei
    Chen, Tongbin
    Wan, Xiaoming
    Dong, Ziping
    Wang, Yuntao
    Qiao, Pengwei
    ANALYTICAL CHEMISTRY, 2019, 91 (09) : 5858 - 5865
  • [33] Energy-dispersive X-ray fluorescence study of elemental uptake in cauliflower
    Gupta, D.
    Chatterjee, J. M.
    Ghose, R.
    Mitra, A. K.
    Roy, S.
    Sarkar, M.
    PRAMANA-JOURNAL OF PHYSICS, 2011, 76 (02): : 344 - 349
  • [34] A portable instrument for energy-dispersive X-ray fluorescence analysis of sulfur
    Castellano, A
    Cesareo, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 129 (02): : 281 - 283
  • [35] Energy-dispersive X-ray fluorescence methods for environmental characterization of soils
    Goldstein, SJ
    Slemmons, AK
    Canavan, HE
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (07) : 2318 - 2321
  • [36] An overview of quantification methods in energy-dispersive X-ray fluorescence analysis
    Markowicz, A.
    PRAMANA-JOURNAL OF PHYSICS, 2011, 76 (02): : 321 - 329
  • [37] Portable instrument for energy-dispersive X-ray fluorescence analysis of sulfur
    Universita di Lecce, Lecce, Italy
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1997, 129 (02): : 281 - 283
  • [38] Energy-dispersive X-ray fluorescence study of elemental uptake in cauliflower
    Gupta D.
    Chatterjee J.M.
    Ghose R.
    Kmitra A.
    Roy S.
    Sarkar M.
    Pramana, 2011, 76 (2) : 345 - 349
  • [39] Review of energy-dispersive X-ray fluorescence on food elements detection
    Li, Fei
    Meng, Lu
    Ding, Wenwan
    Wang, Jiamei
    Ge, Liangquan
    X-RAY SPECTROMETRY, 2022, 51 (04) : 346 - 364
  • [40] An overview of quantification methods in energy-dispersive X-ray fluorescence analysis
    A MARKOWICZ
    Pramana, 2011, 76 : 321 - 329