Modelling tomographic cone-beam projection data from a polyhedral phantom

被引:4
|
作者
Davis, GR [1 ]
机构
[1] Univ London, Dent Biophys Sect, Dept Oral Growth & Dev, Barts & London Queen Marys Sch Med & Dent, London E1 4NS, England
关键词
tomography; phantom; linear attenuation coefficient;
D O I
10.1088/0957-0233/13/8/323
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Analytical phantoms are used to generate projection data for testing reconstruction accuracy in computed axial tomography. A circular source locus (equivalent to rotating specimen with a fixed source) provides insufficient data for 'exact' reconstruction in cone-beam transmission tomography, thus phantom data are useful for studying the consequent errors and also for investigating alternative scanning loci and reconstruction techniques. We present an algorithm that can compute phantom cone-beam projection data from a phantom comprising geometrically defined polyhedra. Each polyhedron is defined as a set of polygons enclosing a volume of fixed linear attenuation coefficient. The algorithm works by projecting each polygon in turn onto the modelled detector array, which accumulates the product of source to polygon intersection distance (for the rays intersecting each detector element), linear attenuation coefficient and sign of projected polygon area (indicating whether rays enter or exit the polyhedron at this face). The phantom data are rotated according to the projection angle, whilst the source location and detector plane remain fixed. Polyhedra can be of simple geometric form, or complex surfaces derived from 3D images of real specimens. This algorithm is illustrated using a phantom comprising 989 238 polygons, representing an iso-surface generated from a microtomographic reconstruction of a piece of walrus tusk.
引用
收藏
页码:1336 / 1340
页数:5
相关论文
共 50 条
  • [21] An alternative derivation of image reconstruction on a chord from cone-beam projection
    Emil Sidky
    中国体视学与图像分析, 2005, (03) : 134 - 136
  • [22] Kinetic parameter estimation from SPECT cone-beam projection measurements
    Huesman, RH
    Reutter, BW
    Zeng, GL
    Gullberg, GT
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 973 - 982
  • [23] Reconstruction from incomplete data in cone-beam tomography
    Hiriyannaiah, HP
    Satyaranjan, M
    Ramakrishnan, KR
    OPTICAL ENGINEERING, 1996, 35 (09) : 2748 - 2760
  • [24] Cone-beam reprojection using projection-matrices
    Galigekere, RR
    Wiesent, K
    Holdsworth, DW
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (10) : 1202 - 1214
  • [25] SYNTHETIC SCANNER ARRAYS IN TOMOGRAPHIC RECONSTRUCTIONS FROM FAN-BEAM AND CONE-BEAM PROJECTIONS
    MULLER, M
    ARCE, GR
    BLAKE, RA
    APPLIED OPTICS, 1994, 33 (35): : 8255 - 8269
  • [26] A comparison of phase, amplitude, and velocity binning for cone-beam computed tomographic projection-based motion reconstruction
    Becker, Nathan
    Quirk, Sarah
    Kay, Ian
    Braverman, Boris
    Smith, Wendy L.
    PRACTICAL RADIATION ONCOLOGY, 2013, 3 (04) : E209 - E217
  • [27] INVERSION OF INCOMPLETE CONE-BEAM DATA
    RAMM, AG
    ZASLAVSKY, AI
    APPLIED MATHEMATICS LETTERS, 1992, 5 (04) : 91 - 94
  • [28] On random noise effect on the cone-beam tomographic reconstruction accuracy
    Shaposhnikova, E
    KORUS 2004, Vol 1, Proceedings, 2004, : 146 - 149
  • [29] Forest representation of vessels in cone-beam computed tomographic angiography
    Chen, ZK
    Ning, RL
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (01) : 1 - 14
  • [30] TOMOGRAPHIC IMAGING OF THE DISTAL EXTREMITIES USING CONE-BEAM COLLIMATION
    COOPER, JA
    MAHMOOD, MM
    SMITH, HS
    MCCANDLESS, BK
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : 914 - 917