Modelling tomographic cone-beam projection data from a polyhedral phantom

被引:4
|
作者
Davis, GR [1 ]
机构
[1] Univ London, Dent Biophys Sect, Dept Oral Growth & Dev, Barts & London Queen Marys Sch Med & Dent, London E1 4NS, England
关键词
tomography; phantom; linear attenuation coefficient;
D O I
10.1088/0957-0233/13/8/323
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Analytical phantoms are used to generate projection data for testing reconstruction accuracy in computed axial tomography. A circular source locus (equivalent to rotating specimen with a fixed source) provides insufficient data for 'exact' reconstruction in cone-beam transmission tomography, thus phantom data are useful for studying the consequent errors and also for investigating alternative scanning loci and reconstruction techniques. We present an algorithm that can compute phantom cone-beam projection data from a phantom comprising geometrically defined polyhedra. Each polyhedron is defined as a set of polygons enclosing a volume of fixed linear attenuation coefficient. The algorithm works by projecting each polygon in turn onto the modelled detector array, which accumulates the product of source to polygon intersection distance (for the rays intersecting each detector element), linear attenuation coefficient and sign of projected polygon area (indicating whether rays enter or exit the polyhedron at this face). The phantom data are rotated according to the projection angle, whilst the source location and detector plane remain fixed. Polyhedra can be of simple geometric form, or complex surfaces derived from 3D images of real specimens. This algorithm is illustrated using a phantom comprising 989 238 polygons, representing an iso-surface generated from a microtomographic reconstruction of a piece of walrus tusk.
引用
收藏
页码:1336 / 1340
页数:5
相关论文
共 50 条
  • [1] CONVOLUTIONAL RECONSTRUCTION FROM CONE-BEAM PROJECTION DATA
    MINERBO, GN
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2682 - 2684
  • [3] Image reconstruction from rebinned helical cone-beam projection data
    Xia, Dan
    Yu, Lifeng
    Bian, Junguo
    Pan, Xiaochuan
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [4] Generalized Feldkamp image reconstruction from equiangular cone-beam projection data
    Wang, B
    Liu, H
    Wang, G
    13TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2000), PROCEEDINGS, 2000, : 123 - 128
  • [5] Interior Reconstruction from Truncated Projection Data in Cone-beam Computed Tomography
    Wang Xianchao
    Li Shaoyi
    Hou Changhui
    Journal of Digital Imaging, 2023, 36 : 250 - 258
  • [6] Interior Reconstruction from Truncated Projection Data in Cone-beam Computed Tomography
    Wang Xianchao
    Li Shaoyi
    Hou Changhui
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (01) : 250 - 258
  • [7] Accurate Noise Modeling of Cone-Beam CT Projection Data
    Wang, J.
    Xing, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] ROI RECONSTRUCTION FROM TRUNCATED CONE-BEAM PROJECTION
    Azencott, Robert
    Bodmann, Bernhard G.
    Chowdhury, Tasadduk
    Labate, Demetrio
    Sen, Anando
    Vera, Daniel
    INVERSE PROBLEMS AND IMAGING, 2018, 12 (01) : 29 - 57
  • [9] Rectification for cone-beam projection and backprojection
    Riddell, Cyril
    Trousset, Yves
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 950 - 962
  • [10] TOMOGRAPHIC RECONSTRUCTION FROM EXPERIMENTALLY OBTAINED CONE-BEAM PROJECTIONS
    WEBB, S
    SUTCLIFFE, J
    BURKINSHAW, L
    HORSMAN, A
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (01) : 67 - 73