On-line monitoring of batch cooling crystallization of organic compounds using ATR-FTIR spectroscopy coupled with an advanced calibration method

被引:31
|
作者
Chen, Zeng-Ping [1 ,2 ]
Morris, Julian [2 ]
Borissova, Antonia [3 ]
Khan, Shahid [3 ]
Mahmud, Tariq [3 ]
Penchev, Rado [3 ]
Roberts, Kevin J. [3 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemobiosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
[2] Univ Newcastle, Sch Chem Engn & Adv Mat, Ctr Proc Analyt & Control Technol, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[3] Univ Leeds, Sch Proc Environm & Mat Engn, Inst Particle Sci & Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
Batch cooling crystallization; ATR-FTIR; Multivariate calibration; Extended loading space standardization; INDUCED SPECTRAL VARIATION; IN-SITU; DIRECT DESIGN; CITRIC-ACID; TEMPERATURE; SUPERSATURATION;
D O I
10.1016/j.chemolab.2008.11.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
During on-line monitoring and control of batch cooling crystallization using ATR-FTIR spectroscopy, appropriate calibration procedures are indispensable to the conversion of the spectroscopic measurements into useful and informative in-situ concentration predictions. The commonly used empirical transmittance ratio models cannot effectively handle complicated systems where the absorption bands appearing from solute and solvent overlap each other or the characteristic absorption bands of solute are rather weak and prone to noise. The conventional multivariate bilinear calibration modelling approaches of PCR and PLS are not capable of explicitly modelling with acceptable accuracy the temperature-induced spectral variations, the scaling effect resulting from the use of concentration units in mass-mass/mass-volume ratio rather than molarity, and the multiplicative effects caused by potential variations in optical path-length. In this contribution, an advanced chemometric methodology, termed extended loading space standardization, is presented and shown to be able to explicitly address the above issues. This is demonstrated by application to the on-line monitoring of the batch cooling crystallization of two organic compounds, monosodium glutamate and L-glutamic acid respectively using ATR-FTIR spectroscopy. The results showed that using extended loading space standardization has enhanced predictive performance than conventional multivariate bilinear calibration methods due to its ability in efficiently handling the impact of temperature and multiplicative effects. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [41] Detection of goat body fat adulteration in pure ghee using ATR-FTIR spectroscopy coupled with chemometric strategy
    Neelam Upadhyay
    Pranita Jaiswal
    Shyam Narayan Jha
    [J]. Journal of Food Science and Technology, 2016, 53 : 3752 - 3760
  • [42] Off-line monitoring of butyl acrylate, methyl methacrylate and vinyl acetate homo- and copolymerizations in toluene using ATR-FTIR spectroscopy
    Hua, H
    Dubé, MA
    [J]. POLYMER, 2001, 42 (14) : 6009 - 6018
  • [43] On-line ATR FTIR measurement of supersaturation during solution crystallization processes.: Calibration and applications on three solute/solvent systems
    Lewiner, F
    Klein, JP
    Puel, F
    Févotte, G
    [J]. CHEMICAL ENGINEERING SCIENCE, 2001, 56 (06) : 2069 - 2084
  • [44] Application of on-line Raman spectroscopy on monitoring semi-batch anti-solvent crystallization
    Han, Bing
    Sha, Zuoliang
    Qu, Haiyan
    Louhi-Kultanen, Marjatta
    Wang, Xuekui
    [J]. CRYSTENGCOMM, 2009, 11 (05): : 827 - 831
  • [45] Rapid and simultaneous determination of physical and chemical properties of asphalt by ATR-FTIR spectroscopy combined with a novel calibration-free method
    Sun, Xiting
    Yuan, Hongfu
    Song, Chunfeng
    Deng, Xiaoxu
    Lv, Guanglong
    Li, Xiaoyu
    Hu, Aiqin
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2020, 230 (230)
  • [46] On-line Quantitative Monitoring and Control of Tobacco Flavors by Near Infrared Spectroscopy Combined with Advanced Calibration Transfer Method
    Shi Xin-Zhen
    Wang Zhi-Guo
    Du Wen
    Yi Hao
    Zhang Juan
    Chen Zeng-Ping
    Yu Ru-Qin
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (11) : 1673 - 1678
  • [47] Monitoring Batch Cooling Crystallization Using NIR: Development of Calibration Models Using Genetic Algorithm and PLS
    Li, Rui F.
    Wang, Xue Z.
    Abebe, Solomon B.
    [J]. PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2008, 25 (04) : 314 - 327
  • [48] Differentiation of Mesothelioma from Lung Cancer and Healthy Individuals Using Human Serum by ATR-FTIR Spectroscopy Coupled with Chemometrics
    Emri, Salih A.
    Yonar, Dilek
    Sandal, Abdulsamet
    Yilmaz, Ulku
    Severcan, Feride
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S631 - S631
  • [49] Techniques of On-Line Monitoring Volatile Organic Compounds in Ambient Air with Optical Spectroscopy
    Du Zhen-hui
    Zhai Ya-qiong
    Li Jin-yi
    Hu Bo
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (12) : 3199 - 3203
  • [50] Rapid and non-destructive quality verification of epoxy resin product using ATR-FTIR spectroscopy coupled with chemometric methods
    Zhang, Wenqing
    Yin, Liang
    Zhao, Ming
    Tan, Zhaoyuan
    Li, Guiyang
    [J]. MICROCHEMICAL JOURNAL, 2021, 168