Investigation of lesion detectability in dynamic PET data sets

被引:0
|
作者
Wang, Guobao [1 ]
Qi, Jinyi [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
关键词
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Dynamic positron emission tomography (PET) has strong potentials for improving detection of cancers at their early stage. However, dynamic PET images are difficult to manipulate by human observers in the detection task because of the huge data size (313 in space + ID in time). One approach to reducing the size is to fit the dynamic images into a compartmental model and use the kinetic parameter images for tumor detection. In this paper we use numerical observers to investigate the performances of different approaches to the utilization of temporal information in dynamic PET for the detection task. Both object variability and measurement noise are considered in the Monte Carlo simulation. The results provide a useful guidance for the proper utilization of dynamic PET for tumor detection.
引用
收藏
页码:1344 / +
页数:2
相关论文
共 50 条
  • [21] Improving lesion detectability in PET imaging with a penalized likelihood reconstruction algorithm
    Wangerin, Kristen A.
    Ahn, Sangtae
    Ross, Steven G.
    Kinahan, Paul E.
    Manjeshwar, Ravindra M.
    [J]. MEDICAL IMAGING 2015: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2015, 9416
  • [22] Effect of attenuation correction on lesion detectability in FDG PET of breast cancer
    Bleckmann, C
    Dose, J
    Bohuslavizki, KH
    Buchert, R
    Klutmann, S
    Mester, J
    Jänicke, F
    Clausen, M
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (12) : 2021 - 2024
  • [23] THEORETICAL ANALYSIS OF LESION DETECTABILITY IN PENALIZED MAXIMUM-LIKELIHOOD PATLAK PARAMETRIC IMAGE RECONSTRUCTION USING DYNAMIC PET
    Yang, Li
    Wang, Guobao
    Qi, Jinyi
    [J]. 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1188 - 1191
  • [24] Clinical assessment of lesion detectability in dynamic whole-body PET imaging using compartmental and Patlak parametric mapping
    Zaker, Neda
    Kotasidis, Fotis
    Garibotto, Valentina
    Zaidi, Habib
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [25] Data reduction for lesion detection in dynamic positron-emission tomography (PET)
    Thanyasrisung, Piyapong
    Yu, Xiaoli
    [J]. IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1916 - 1919
  • [26] Effect of patient thickness and scan duration on lesion detectability in PET oncology imaging
    Cheng, PM
    Kinahan, PE
    Comtat, C
    Lartizien, C
    Lewellen, TK
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 960 - 968
  • [27] Lesion detectability in motion compensated image reconstruction of respiratory gated PET/CT
    Thielemans, Kris
    Manjeshwar, Ravindra M.
    Tao, Xiaodong
    Asma, Evren
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3278 - 3282
  • [28] Lesion detectability and quantification in PET/CT oncological studies by Monte Carlo simulations
    Castiglioni, I
    Rizzo, G
    Gilardi, MC
    Bettinardi, V
    Savi, A
    Fazio, F
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 136 - 142
  • [29] Demonstration of PET System Design Trade-offs Using Small Lesion Detectability as a Metric and Measured Phantom Data
    Wollenweber, S. D.
    Kinahan, P. E.
    Alessio, A. M.
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [30] ROC analysis for quantification of lesion detectability in PET: Influence of reconstruction algorithms.
    Glatting, G
    Werner, C
    Reske, SN
    Bellemann, ME
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 268P - 269P