Telemetric System for Monitoring of Endoleak in Abdominal Aorta Aneurysm using Multiple Pressure Sensors integrated on a Stent Graft

被引:0
|
作者
John, Bibin [1 ]
Spink, Clemens [2 ]
Braunschweig, Markus [3 ]
Ranjan, Rajeev [1 ]
Schroeder, Dietmar [1 ]
Koops, Andreas [2 ]
Woldt, Gregor [3 ]
Rauh, Ilka [4 ]
Leuzinger, Andreas [4 ]
Adam, Gerhard [2 ]
Krautschneider, Wolfgang H. [1 ]
机构
[1] Hamburg Univ Technol, Inst Nano & Med Elect, Hamburg, Germany
[2] Univ Hosp Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, Hamburg, Germany
[3] First Sensor Microelect Packaging GmbH, Dresden, Germany
[4] QualiMed Innovat Med Prod GmbH, Winsen, Germany
关键词
Stent graft; Abdominal aortic aneurysm; EVAR; Medical implant; Blood pressure measurement; REPAIR;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An abdominal aortic aneurysm (AAA) is the dilation of the abdominal aorta due to weakening of the arterial wall. Endovascular aneurysm repair (EVAR) using an implantable stent graft is the commonly used method for treatment of AAA. An endoleak, which is the leakage of blood around the stent graft, is the complication after EVAR creating trauma to the weakened arterial walls of the aneurysm leading to further enlargement and risk of rupture. This paper details the design, implementation and testing of a wirelessly powered implant device containing multiple pressure sensors to be mounted on a stent graft for detecting endoleak. The tested implant device can be powered for distance of 20 cm using an external RF power source of 2.65 W. A stent prototype with sixteen pressure sensors is fabricated and tested using an in-vitro chamber. The resolution and directionality of the pressure sensors in the stent prototype are measured. Different wirebonding glob top encapsulations are evaluated for mechanical stress induced during stent delivery.
引用
收藏
页码:384 / 387
页数:4
相关论文
共 50 条
  • [1] Delayed type IIIb endoleak using Anaconda™ stent graft in abdominal aortic aneurysm repair
    Wu Zi-heng
    Raithel, Dieter
    Qu Le-feng
    [J]. CHINESE MEDICAL JOURNAL, 2010, 123 (18) : 2623 - 2624
  • [2] Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA)
    Li, Jie
    Tian, Xiaopeng
    Wang, Zhenze
    Xiong, Jiang
    Fan, Yubo
    Deng, Xiaoyan
    Sun, Anqiang
    Liu, Xiao
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [3] Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA)
    Jie Li
    Xiaopeng Tian
    Zhenze Wang
    Jiang Xiong
    Yubo Fan
    Xiaoyan Deng
    Anqiang Sun
    Xiao Liu
    [J]. BioMedical Engineering OnLine, 15
  • [4] Hemodynamic Effects of Endoleak Formation in Abdominal Aortic Aneurysm Patients with Stent-Graft Implants
    Lu, Yueh-Hsun
    Chen, Chia-Yuan
    Menon, Prahlad G.
    Liu, Kuan-Ting
    Lin, Hsing-Hung
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (06) : 554 - 558
  • [5] Type II Endoleak After Endovascular Aortic Aneurysm Repair Using the Endurant Stent Graft System for Abdominal Aortic Aneurysm with Occluded Inferior Mesenteric Artery
    Gentsu, Tomoyuki
    Okada, Takuya
    Yamaguchi, Masato
    Horinouchi, Hiroki
    Katayama, Naoto
    Ueshima, Eisuke
    Koide, Yutaka
    Sofue, Keitaro
    Gotake, Yasuko
    Nomura, Yoshikatsu
    Tanaka, Hiroshi
    Okita, Yutaka
    Sugimoto, Koji
    Murakami, Takamichi
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (04) : 505 - 512
  • [6] Type II Endoleak After Endovascular Aortic Aneurysm Repair Using the Endurant Stent Graft System for Abdominal Aortic Aneurysm with Occluded Inferior Mesenteric Artery
    Tomoyuki Gentsu
    Takuya Okada
    Masato Yamaguchi
    Hiroki Horinouchi
    Naoto Katayama
    Eisuke Ueshima
    Yutaka Koide
    Keitaro Sofue
    Yasuko Gotake
    Yoshikatsu Nomura
    Hiroshi Tanaka
    Yutaka Okita
    Koji Sugimoto
    Takamichi Murakami
    [J]. CardioVascular and Interventional Radiology, 2019, 42 : 505 - 512
  • [7] Acute symptomatic abdominal aortic aneurysm secondary to endovascular stent graft associated type II endoleak
    Chan, Karen Ka Leung
    Siu, Wing Tai
    Fung, Kai Hung
    Yau, Kwok Kay
    Wong, Simon Kin Hung
    Li, Michael Ka Wah
    [J]. ASIAN JOURNAL OF SURGERY, 2006, 29 (03) : 157 - 160
  • [8] Type IIIb Endoleak After Endovascular Aneurysm Repair Using the Zenith Stent Graft
    Nishibe, Toshiya
    Iwahashi, Toru
    Kamiya, Kentaro
    Kano, Masaki
    Maruno, Keita
    Koizumi, Jun
    Dardik, Alan
    Ogino, Hitoshi
    [J]. VASCULAR AND ENDOVASCULAR SURGERY, 2019, 53 (06) : 515 - 519
  • [9] Avoidance of Proximal Endoleak Using a Hybrid Stent Graft in Arch Replacement and Descending Aorta Stenting
    Tsagakis, Konstantinos
    Kamler, Markus
    Kuehl, Hilmar
    Kowalczyk, Wojciech
    Tossios, Paschalis
    Thielmann, Matthias
    Osswald, Brigitte
    Erbel, Raimund
    Eggebrecht, Holger
    Jakob, Heinz
    [J]. ANNALS OF THORACIC SURGERY, 2009, 88 (03): : 773 - 780
  • [10] Incidence of stent graft failure from type IIIB endoleak in contemporary endovascular abdominal aortic aneurysm repair
    Kwon, Jeontaik
    Dimuzio, Paul
    Salvatore, Dawn
    Abai, Babak
    [J]. JOURNAL OF VASCULAR SURGERY, 2020, 71 (02) : 645 - 653