Hemodynamic Effects of Endoleak Formation in Abdominal Aortic Aneurysm Patients with Stent-Graft Implants

被引:3
|
作者
Lu, Yueh-Hsun [1 ,2 ,3 ]
Chen, Chia-Yuan [4 ]
Menon, Prahlad G. [5 ]
Liu, Kuan-Ting [4 ]
Lin, Hsing-Hung [4 ]
机构
[1] Taipei City Hosp, Zhongxing Branch, Dept Radiol, Taipei 103, Taiwan
[2] Taipei Vet Gen Hosp, Dept Radiol, Taipei 112, Taiwan
[3] Natl Yang Ming Univ, Sch Med, Taipei 112, Taiwan
[4] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei 106, Taiwan
[5] Sun Yat Sen Univ Carnegie Mellon Univ, Joint Inst Engn, Dept Elect & Comp Engn, Pittsburgh, PA 15213 USA
关键词
Endoleak; Abdominal aortic aneurysm; Stent-graft; Hemodynamics; Fluid-structure interaction; ENDOVASCULAR REPAIR; PATHOGENESIS;
D O I
10.5405/jmbe.1588
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Endoleaks may evolve and become severe post-surgical complications in patients with abdominal aortic aneurysms (AAAs). After endovascular aortic aneurysm repair (EVAR), endoleaks may induce EVAR failure. Therefore, the early detection and management of endoleak development could help reduce the need for reoperation. An endoleak is characterized by blood flow that leaks into the cavity between the stent-graft (SG) and aneurysm sac. Comprehensive hemodynamic analysis can identify the relationship of flow-induced wall stress and endoleak formation. Given this hypothesis, a numerical analysis of fluid-structure interaction was performed in this study. SG geometry and AAA flow dynamics were incorporated using the physiological conditions of three patient-specific models of AAA after EVAR. Endoleak locations were well matched to the local peak locations of von Mises stress in the aneurysm bulges of these patients. Further investigation on the associated blood flow structures could provide insights on the physical relationship between hemodynamic force and endoleak formation. The presented analytical procedure offers a reliable alternative for endoleak prediction and detection. This method may be used for post-EVAR patient care with sophisticated imaging techniques such as magnetic resonance, computed tomography, and digital subtraction angiography.
引用
收藏
页码:554 / 558
页数:5
相关论文
共 50 条
  • [1] EFFECTS OF STENT-GRAFT GEOMETRY AND BLOOD HEMATOCRIT ON HEMODYNAMIC IN ABDOMINAL AORTIC ANEURYSM
    Polanczyk, Andrzej
    Podyma, Marek
    Stefanczyk, Ludomir
    Zbicinski, Ireneusz
    [J]. CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2012, 33 (01): : 53 - 61
  • [2] Stent-graft repair for abdominal aortic aneurysm
    Kalman, PG
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 1999, 161 (09) : 1133 - 1133
  • [3] Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis
    Nicolas Aristokleous
    Nikolaos G. Kontopodis
    Konstantinos Tzirakis
    Christos V. Ioannou
    Yannis Papaharilaou
    [J]. Medical & Biological Engineering & Computing, 2016, 54 : 1523 - 1532
  • [4] Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis
    Aristokleous, Nicolas
    Kontopodis, Nikolaos G.
    Tzirakis, Konstantinos
    Ioannou, Christos V.
    Papaharilaou, Yannis
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (10) : 1523 - 1532
  • [5] Abdominal aortic aneurysm: Overview of stent-graft devices
    Criado, FJ
    Barnatan, MF
    Lingelbach, JM
    Mills, JD
    Richards, BE
    Morgan, WR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2002, 194 (01) : S88 - S97
  • [6] Endoleak after stent-graft treatment of abdominal aortic aneurysm: a meta-analysis of clinical studies
    Schurink, GWH
    Aarts, NJM
    van Bockel, JH
    [J]. BRITISH JOURNAL OF SURGERY, 1999, 86 (05) : 581 - 587
  • [7] Computational fluid dynamics: Hemodynamic changes in abdominal aortic aneurysm after stent-graft implantation
    Frauenfelder, Thomas
    Lotfey, Mourad
    Boehm, Thomas
    Wildermuth, Simon
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (04) : 613 - 623
  • [8] Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation
    Thomas Frauenfelder
    Mourad Lotfey
    Thomas Boehm
    Simon Wildermuth
    [J]. CardioVascular and Interventional Radiology, 2006, 29 : 613 - 623
  • [9] Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation
    Thomas Frauenfelder
    Mourad Lotfey
    Thomas Boehm
    Simon Wildermuth
    [J]. CardioVascular and Interventional Radiology, 2006, 29 : 724 - 724
  • [10] Separation of the Modular Stent-Graft Within the Abdominal Aortic Aneurysm
    Tsao, Nai-Wen
    Shih, Chun-Ming
    Lin, Feng-Yen
    Shao, Wen-Tein
    Lee, Chi-Ming
    Ou, Keng-Liang
    Chang, Nein-Chun
    Huang, Chun-Yao
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (12) : E199 - E199