Comparison of the performance of two different DOAS configurations involving conventional and renewable energies

被引:7
|
作者
Martinez, Pedro J. [1 ]
Martinez, Pedro [1 ]
Soto, Victor M. [2 ]
Kaiser, Antonio S. [3 ]
机构
[1] Univ Miguel Hernandes, Dept Ingn Mecan & Energia, Avda Univ S-N, Elche 03202, Spain
[2] Univ Politecn Valencia, Dept Termodinam Aplicada, Camino Vera S-N, E-46022 Valencia, Spain
[3] Univ Politecn Cartagena, Dept Ingn Term & Fluidos, Dr Fleming S-N, Cartagena 30202, Spain
关键词
Desiccant wheel; Solar air collector; TRNSYS; Indirect evaporative cooling; EES; AIR HANDLING UNIT; DESICCANT; BUILDINGS; SYSTEM;
D O I
10.1016/j.solener.2018.05.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Spanish building regulations have increased the ventilation rates creating humidity control problems. Dedicated outdoor air systems (DOASs) including a desiccant wheel can dry the ventilation air so that the cooling units are relieved of the latent loads carried by the ventilation air and those generated inside the building. The purpose of this study was to compare the performance of two different DOAS configurations in terms of primary energy consumption under different Spanish climates. The DOAS comprising a desiccant wheel and a conventional refrigeration system was called DOAS-A. The DOAS comprising a desiccant wheel regenerated by solar air collectors and an indirect evaporative cooler was called DOAS-B. The performance of both DOASs was simulated with TRNSYS, and the models were validated with data from experimental setups built at the Miguel Hernandez University of Elche (Spain) and at the Technical University of Cartagena (Spain). It was found that the DOAS-B configuration consumed less primary energy than the DOAS-A configuration for commercial use, that is, when the latent load coincides with the supply of solar radiation. These savings reached 68.3% in Seville owing to its high level of solar radiation. It was also found that the net sensible load supplied by the ventilation air to the conditioned space was negative for all climates. This sensible cooling capacity was shown to be greater at lower outdoor dry-bulb temperature and lower latent load.
引用
收藏
页码:284 / 296
页数:13
相关论文
共 50 条
  • [41] Performance comparison of different receiver configurations in an all-optical chaotic transmission system
    Kanakidis, D
    Bogris, A
    Argyris, A
    Syvridis, D
    SEMICONDUCTOR LASERS AND LASER DYNAMICS, 2004, 5452 : 389 - 398
  • [42] Head-to-head hydrodynamic performance comparison of six foil setups with four and two foil configurations on trimarans in different operational conditions
    Ghadimi, Aliakbar
    Ghassemi, Hassan
    Ghadimi, Parviz
    PHYSICS OF FLUIDS, 2025, 37 (04)
  • [43] SENSITIVITY COMPARISON OF TWO L-ALANINE DOPED BLENDS TO DIFFERENT PHOTON ENERGIES
    Chen, Felipe
    Vega Ramirez, Jose
    Nicolucci, Patricia
    Baffa, Oswaldo
    HEALTH PHYSICS, 2010, 98 (02): : 383 - 387
  • [44] Energy and exergy performance comparison of different configurations of an absorption-two-stage compression cascade refrigeration system with carbon dioxide refrigerant
    Mohammadi, S. M. Hojjat
    Ameri, Mehran
    APPLIED THERMAL ENGINEERING, 2016, 104 : 104 - 120
  • [45] Optical performance comparison of two receiver configurations for medium temperature Linear Fresnel Collectors
    Montenon, Alaric Christian
    Santos, Andre Vitor
    Collares-Pereira, Manuel
    Montagnino, Fabio Maria
    Garofalo, Roberto
    Papanicolas, Costas
    SOLAR ENERGY, 2022, 240 : 225 - 236
  • [46] Techno-economic comparison of different energy storage configurations for renewable energy combined cooling heating and power system
    Huang, Z. F.
    Chen, W. D.
    Wan, Y. D.
    Shao, Y. L.
    Islam, M. R.
    Chua, K. J.
    APPLIED ENERGY, 2024, 356
  • [47] Comparison of the adsorption behaviors for methylene blue on two renewable gels with different physical state
    Qiu, Jinli
    Fan, Pei
    Feng, Yuefeng
    Liu, Fuqiang
    Ling, Chen
    Li, Aimin
    ENVIRONMENTAL POLLUTION, 2019, 254
  • [48] Performance comparison of two telescope configurations for backscattered light in space gravitational wave detection
    Wang, Yiping
    Li, Zizheng
    Zhou, Jinhang
    Song, Jie
    Luo, Zhenning
    Liu, Xinxin
    Zhao, Hongchao
    Fan, Lei
    Yan, Yong
    APPLIED OPTICS, 2025, 64 (07) : 1639 - 1645
  • [49] Performance comparison of pH Neutralization process among different tunings of conventional controllers
    Kumar, D. Dinesh
    Deepika, D.
    ADVANCEMENTS IN AUTOMATION AND CONTROL TECHNOLOGIES, 2014, 573 : 260 - 266
  • [50] Comparison of stone comminution produced by two different reflector configurations in an HM-3 lithotripter
    Qin, Jun
    Simmons, W. Neal
    Zhong, Pei
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 2: BIOMEDICAL AND BIOTECHNOLOGY ENGINEERING, 2008, : 281 - 284