Introduction of Annular Vortex Tube and experimental comparison with Ranque-Hilsch Vortex Tube

被引:26
|
作者
Sadi, Meisam [1 ]
Farzaneh-Gord, Mahmood [1 ]
机构
[1] Shahrood Univ Technol, Dept Mech Engn, Semnan, Iran
关键词
Vortex tube; Annular Vortex Tube; Vortex generator; Optimum cold mass fraction; NATURAL-GAS; FLOW; ENERGY; SEPARATION; TEMPERATURE; PARAMETERS;
D O I
10.1016/j.ijrefrig.2014.07.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to enhance the Ranque-Hilsch Vortex Tube (RHVT) performance, an improved design of a Vortex Tube (VT) is introduced here. The new design of the VT which called Annular Vortex Tube (AVT) is experimentally tested and compared with a similar design RHVT. The hot stream, after passing the hot conical valve, redirected along the outer wall of hot tube in the AVT. This increases heat lost from outer wall of the hot tube. Results show that AVT has higher thermal separation performance comparing to RHVT. For optimum cold mass fraction, AVT improves cooling efficiency about 24% comparing to RHVT. The conical valve angle has also no effect on thermal performance of AVT. For AVT, three vortex generators are tested with different nozzle areas. All vortex generators have the same coefficient of performance in heating while vortex generator with higher nozzle area ratio represents better cooling efficiency among the others. (C) 2014 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:142 / 151
页数:10
相关论文
共 50 条
  • [41] Computational investigation of precessing vortex breakdown and energy separation in a Ranque-Hilsch vortex tube
    Guo, Xiangji
    Zhang, Bo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 85 : 42 - 57
  • [42] Computational investigation of different effects on the performance of the Ranque-Hilsch vortex tube
    Kandil, Hamdy A.
    Abdelghany, Seif T.
    ENERGY, 2015, 84 : 207 - 218
  • [43] Experimental study on the impact of pressure ratio on temperature drop in a Ranque-Hilsch vortex tube
    Parker, Mark J.
    Straatman, Anthony G.
    APPLIED THERMAL ENGINEERING, 2021, 189
  • [44] A new vortex generator geometry for a counter-flow Ranque-Hilsch vortex tube
    Aydin, Orhan
    Markal, Burak
    Avci, Mete
    APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2505 - 2511
  • [45] Fluid properties impact on energy separation in Ranque-Hilsch vortex tube
    Alsaghir, Ahmad
    Hamdan, Mohammad O.
    Orhan, Mehmet F.
    SN APPLIED SCIENCES, 2022, 4 (08):
  • [46] LDA-based experimental study of flow crisis in the Ranque-Hilsch vortex tube
    Kabardin, I. K.
    THERMOPHYSICS AND AEROMECHANICS, 2022, 29 (05) : 673 - 681
  • [47] CHED 337-Construction and experimentation of a Ranque-Hilsch vortex tube
    Gutierrez, Lizette
    Smith, Charles A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 232
  • [48] A new approach to selective brain cooling by a Ranque-Hilsch vortex tube
    Fazel Bakhsheshi M.
    Wang Y.
    Keenliside L.
    Lee T.-Y.
    Intensive Care Medicine Experimental, 4 (1)
  • [49] Wavelet Transform Of Acoustic Signal From A Ranque-Hilsch Vortex Tube
    Istihat, Y.
    Wisnoe, W.
    7TH INTERNATIONAL CONFERENCE ON COOLING & HEATING TECHNOLOGIES (ICCHT 2014), 2015, 88
  • [50] CFD analysis of different working gases in Ranque-Hilsch vortex tube
    Ambedkar P.
    Dutta T.
    Materials Today: Proceedings, 2023, 72 : 761 - 767