Silicon sensors for the CMS preshower detector

被引:8
|
作者
Bloch, P
Chang, YH
Chen, AE
Cheremukhin, A
Egorov, N
Go, A
Golubkov, S
Golutvin, I
Hou, SR
Konjkov, K
Kozlov, Y
Kyriakis, A
Lin, WT
Loukas, D
Markou, A
Mousa, J
Peisert, A [1 ]
Sidorov, A
Tsoi, E
Zamiatin, N
Zubarev, E
机构
[1] CERN, Geneva, Switzerland
[2] NCU, Chungli, Taiwan
[3] Joint Inst Nucl Res Dubna, Dubna, Russia
[4] RIMST, ELMA, Zelenograd, Russia
[5] NCSR Demokritos, Athens, Greece
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2002年 / 479卷 / 2-3期
关键词
CMS; preshower; silicon strips; radiation hardness;
D O I
10.1016/S0168-9002(01)00900-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper is a summary of a research and development programme, conducted during the past 3 years on the CMS Preshower silicon sensors to define the specifications. The main purpose was to study the radiation hardness of these devices resulting from the specific design (metal lines wider than the p(+) implants) and the production technology, a deep n(+) layer on the ohmic side. An acceptable noise and a uniform charge collection were guaranteed by an appropriate choice of the interstrip region width. About 65 sensors, of different designs and produced by six manufacturers, were irradiated with neutrons and protons and thoroughly tested before and after irradiation. The results of the tests and the final specifications are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:265 / 277
页数:13
相关论文
共 50 条
  • [21] THE DESIGN OF THE DO PRESHOWER DETECTOR
    QIAN, JM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 524 - 528
  • [22] Planar sensors for the upgrade of the CMS pixel detector
    Rohe, T.
    Bean, A.
    Radicci, V.
    Sibille, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01): : 136 - 139
  • [23] Optimization of the silicon sensors for the CMS tracker
    Albergo, S
    Angarano, M
    Azzi, P
    Babucci, E
    Bacchetta, N
    Bader, A
    Bagliesi, G
    Basti, A
    Biggeri, U
    Biino, C
    Bilei, GM
    Bisello, D
    Boemi, D
    Bosi, F
    Borello, L
    Braibant, S
    Breuker, H
    Brunetti, MT
    Bruzzi, M
    Buffini, A
    Busoni, S
    Candelori, A
    Caner, A
    Castaldi, R
    Castro, A
    Catacchini, E
    Checcucci, B
    Ciampolini, P
    Civinini, C
    Costa, M
    Creanza, D
    D'Alessandro, R
    DeMaria, N
    de Palma, M
    Dell'Orso, R
    Dutta, S
    Favro, G
    Fiore, L
    Focardi, E
    French, M
    Freudenreich, K
    Frey, A
    Friedl, M
    Fürtjes, A
    Giassi, A
    Giorgi, M
    Giraldo, A
    Glessing, W
    Gu, WH
    Hall, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (02): : 300 - 307
  • [24] Measurement of the bulk leakage current of silicon sensors of the CMS Preshower after an integrated luminosity of 6.17 fb-1, at √s=7 TeV
    Barney, D.
    Guthoff, M.
    Honma, A.
    Li, S-W.
    Peisert, A.
    Tzeng, Y-M.
    Qin, G.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [25] A study of spatial resolution for a preshower detector with aluminum absorber and silicon strip sampler
    Chang, YH
    Chen, AE
    Hou, SR
    Lin, WT
    Anticic, T
    Chien, CY
    Fisher, PH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (02): : 157 - 163
  • [26] Operation and performance of the CMS silicon tracking detector
    Borgia, Maria Assunta
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 658 (01): : 2 - 5
  • [27] Silicon beam telescope for CMS detector tests
    Eklund, C
    Heikkinen, A
    Honkanen, A
    Karimäki, V
    Mäenpää, T
    Pietarinen, E
    Saarikoski, H
    Skog, K
    Tuominiemi, J
    Tuuva, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 430 (2-3): : 321 - 332
  • [28] EFFECT OF A PRESHOWER DETECTOR ON CALORIMETRY PERFORMANCE
    HULBERT, M
    LEEDOM, I
    REUCROFT, S
    RUUSKA, D
    YASUDA, T
    BHATTI, A
    MELESE, P
    RUSACK, R
    BONAMY, P
    COMBY, G
    ERNWEIN, J
    HUBBARD, JR
    FENKER, H
    MORGAN, K
    REGAN, T
    WANG, ATM
    CUSHMAN, P
    HOU, SR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (03): : 427 - 438
  • [29] The silicon sensors for the High Granularity Calorimeter of CMS
    Paulitsch, Peter
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 978
  • [30] Tests of the silicon strip sensors for the CMS tracker
    Bergauer, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 317 - 320