Application of Synchrotron X-ray Microtomography for Visualizing Bacterial Biofilms 3D Microstructure in Porous Media

被引:15
|
作者
du Roscoat, S. Rolland [1 ,2 ]
Martins, J. M. F. [3 ]
Sechet, P. [4 ]
Vince, E. [3 ]
Latil, P. [1 ]
Geindreau, C. [1 ]
机构
[1] Univ Grenoble 1, Grenoble INP, Lab 3SR, UMR CNRS 5521, F-38041 Grenoble 9, France
[2] European Synchrotron Radiat Facil, F-38043 Grenoble 9, France
[3] Univ Grenoble 1, Grenoble INP, Lab Etud Transferts Hydrol & Environm LTHE, UMR CNRS 5564, F-38041 Grenoble 9, France
[4] Univ Grenoble 1, Grenoble INP, LEGI, UMR CNRS 5519, F-38041 Grenoble 9, France
关键词
biofilm; microtomography; biofilter; porous media; TRANSPORT; FLOW;
D O I
10.1002/bit.25168
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The development of reliable models to accurately predict biofilm growth in porous media relies on a good knowledge of the temporal evolution of biofilms structure within the porous network. Since little is known on the true 3D structure of biofilms developed in porous media, this work aimed at developing a new experimental protocol to visualize the 3D microstructure of bacterial biofilms in porous media. The main originality of the proposed procedure lies on the combination of the more recent advances in synchrotron microtomography (Paganin mode) and of a new contrast agent (1-chloronaphtalene) that has never been applied to biofilm visualization. It is shown that the proposed methodology takes advantage of the contrasting properties of 1-chloronaphtalene to prevent some limitations observed with more classical contrast agents. A quantitative analysis of the microstructural properties (volume fractions and specific surface area) of bacterial biofilms developed in columns of clay beads is also proposed on the basis of the obtained 3D images. Biotechnol. Bioeng. 2014;111: 1265-1271. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1265 / 1271
页数:7
相关论文
共 50 条
  • [21] Direct characterization of solute transport in unsaturated porous media using fast X-ray synchrotron microtomography
    Hasan, Sharul
    Niasar, Vahid
    Karadimitriou, Nikolaos K.
    Godinho, Jose R. A.
    Vo, Nghia T.
    An, Senyou
    Rabbani, Arash
    Steeb, Holger
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2020, 117 (38) : 23443 - 23449
  • [22] Imaging methane hydrates growth dynamics in porous media using synchrotron X-ray computed microtomography
    Kerkar, Prasad B.
    Horvat, Kristine
    Jones, Keith W.
    Mahajan, Devinder
    GEOCHEMISTRY GEOPHYSICS GEOSYSTEMS, 2014, 15 (12) : 4759 - 4768
  • [24] High quality 3D imaging of vertebrate microremains using X-ray synchrotron phase contrast microtomography
    Pouech, Joane
    Mazin, Jean-Michel
    Tafforeau, Paul
    COMPTES RENDUS PALEVOL, 2010, 9 (6-7) : 389 - 395
  • [25] A 3D measurement procedure for internal local crack driving forces via synchrotron X-ray microtomography
    Toda, H
    Sinclair, I
    Buffière, JY
    Maire, E
    Khor, KH
    Gregson, P
    Kobayashi, T
    ACTA MATERIALIA, 2004, 52 (05) : 1305 - 1317
  • [26] Foam trapping in a 3D porous medium:in situobservations by ultra-fast X-ray microtomography
    Poryles, Raphael
    Gland, Nicolas
    King, Andrew
    Rosenberg, Elisabeth
    Barre, Loic
    Chevalier, Thibaud
    SOFT MATTER, 2020, 16 (27) : 6354 - 6361
  • [27] Approaches to 3D printing teeth from X-ray microtomography
    Cresswell-Boyes, A. J.
    Barber, A. H.
    Mills, D.
    Tatla, A.
    Davis, G. R.
    JOURNAL OF MICROSCOPY, 2018, 272 (03) : 207 - 212
  • [28] A 3D study of mortar degradation by X-ray computed microtomography
    Bernard, D
    Chen, D
    Burlion, N
    COMPUTATIONAL METHODS IN MATERIALS CHARACTERISATION, 2004, 6 : 297 - 306
  • [29] Imaging biofilm architecture within porous media using synchrotron-based X-ray computed microtomography
    Iltis, Gabriel C.
    Armstrong, Ryan T.
    Jansik, Danielle P.
    Wood, Brian D.
    Wildenschild, Dorthe
    WATER RESOURCES RESEARCH, 2011, 47
  • [30] Automatic thresholding method for 3D X-ray microtomography analysis
    Sales, E.
    Pereira, W. C. A.
    Gomez, W.
    Lima, I.
    Lopes, R. T.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 409 - 414