Optimization of the phase and modulation depth signal-to-noise ratio for near-infrared spectroscopy of the biological tissue

被引:2
|
作者
Toronov, V [1 ]
D'Amico, E [1 ]
Hueber, D [1 ]
Gratton, E [1 ]
Barbieri, B [1 ]
Webb, A [1 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
来源
SARATOV FALL MEETING 2003: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE V | 2004年 / 5474卷
关键词
photon migration; imaging; brain; near-infrared;
D O I
10.1117/12.578960
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Frequency-domain near-infrared spectroscopy and imaging offer significant advantages over the continuous-wave method in human brain applications. However, the drawback of existing instruments is a low signal-to-noise ratio for measured phase and modulation depth changes caused by cerebral activation. In this paper we show that in the case of the geometry specific for the activated area in the human brain, the SNR can be significantly improved by increasing the modulation frequency. We present the results of a study performed experimentally using a sub-nanosecond pulsed light source and a spherical absorbing object immersed in a highly scattering solution. We show that changes caused by the absorbing inhomogeneity in both phase and modulation depth increase with frequency and reach maximum values at frequencies between 400 and 1400 MHz, depending on the particular source-detector distance. We also show that for the semi-infinite geometry an increase of the modulation frequency from 100 to 500 MHz can increase the phase signal-to-noise ratio 2-3 times, and the modulation depth SNR up to 10 times.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [21] OPTIMIZATION OF SIGNAL-TO-NOISE RATIO OF LATERAL MAGNETOTRANSISTORS
    WIDMER, R
    POPOVIC, RS
    HELVETICA PHYSICA ACTA, 1984, 57 (04): : 542 - 542
  • [22] Optimization of ion trap geometries and of the signal-to-noise ratio for high resolution spectroscopy
    Mihalcea, B. M.
    Visan, G. T.
    Giurgiu, L. C.
    Radan, S.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2008, 10 (08): : 1994 - 1998
  • [23] Relationship between wavelength combination and signal-to-noise ratio in measuring hemoglobin concentrations using visible or near-infrared light
    Tsukasa Funane
    Hirokazu Atsumori
    Hiroki Sato
    Masashi Kiguchi
    Atsushi Maki
    Optical Review, 2009, 16 : 442 - 448
  • [24] Relationship between wavelength combination and signal-to-noise ratio in measuring hemoglobin concentrations using visible or near-infrared light
    Funane, Tsukasa
    Atsumori, Hirokazu
    Sato, Hiroki
    Kiguchi, Masashi
    Maki, Atsushi
    OPTICAL REVIEW, 2009, 16 (04) : 442 - 448
  • [25] Effects of sinusoidal phase modulation on the signal-to-noise ratio in a digital holography system
    Mao, Davin
    Thornton, Douglas E.
    Rice, Christopher A.
    Spencer, Mark F.
    Perram, Glen P.
    UNCONVENTIONAL AND INDIRECT IMAGING, IMAGE RECONSTRUCTION, AND WAVEFRONT SENSING 2019, 2019, 11135
  • [26] Signal-to-noise ratio of spin noise spectroscopy in rubidium vapor
    Ping, Shi
    Jian, Ma
    Xuan, Qian
    Yang, Ji
    Wei, Li
    ACTA PHYSICA SINICA, 2017, 66 (01)
  • [27] Estimation of the signal-to-noise ratio with amplitude modulation spectrograms
    Tchorz, J
    Kollmeier, B
    SPEECH COMMUNICATION, 2002, 38 (1-2) : 1 - 17
  • [28] SIGNAL-TO-NOISE RATIO FOR DOUBLE MODULATION OF THE FLUX IN A SPECTROPHOTOMETER
    VOROBEV, BS
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1980, 47 (04): : 244 - 245
  • [29] Maximisation of signal-to-noise ratio in infrared radiation receivers
    Bielecki, Z
    OPTO-ELECTRONICS REVIEW, 2002, 10 (03) : 209 - 216
  • [30] EFFECT OF ACOUSTIC ISOLATION CHAMBER ON THE SIGNAL-TO-NOISE RATIO IN INFRARED PHOTOACOUSTIC-SPECTROSCOPY
    MAHMOODI, P
    DUERST, RW
    MEIKLEJOHN, RA
    APPLIED SPECTROSCOPY, 1984, 38 (03) : 437 - 438