Effectiveness of a tiny tuned liquid damper on mitigating wind-induced responses of cylindrical solar tower based on elastic wind tunnel tests

被引:13
|
作者
Li, Yafeng [1 ]
Li, Shouying [1 ]
Sun, Beisong [1 ]
Liu, Min [1 ]
Chen, Zhengqing [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Key Lab Wind & Bridge Engn Hunan Prov, Changsha 410082, Peoples R China
关键词
Tuned liquid damper (TLD); Wind-induced responses; Elastic test model; Wind tunnel tests; COLUMN DAMPERS; SUPPRESSION; VIBRATION; MOTION; FLUID; TLD;
D O I
10.1016/j.jweia.2020.104455
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A tiny TLD was specially designed and manufactured to investigate its effectiveness on mitigating the wind-induced responses of a 243-meter-high solar tower by using wind tunnel tests based on an elastic WA model. First, an elastic WA model of the solar tower was made, and its structural parameters, including natural frequency, the first three mode shapes and structural damping ratio, were identified. Second, six types of tiny TLDs with different inner diameters (9, 10, 11, 12, 13 and 14 mm) were designed and manufactured, and the natural frequency and sloshing damping ratio of water in these tiny TLDs were identified to compare them with the theoretical values. The results show the measured and theoretical natural frequencies agree well with each other, while the measured sloshing damping of water is much larger than the theoretical value. Then, a series of wind tunnel tests were carried out to obtain the wind-induced responses of the solar tower. The effectiveness of TLD on mitigating the wind-induced responses of the solar tower was systematically investigated based on a series of parametric studies. The results show the wind-induced responses in the cross-wind and along-wind directions, including the acceleration at the top, the shear and moment at the bottom, can all be significantly reduced by the tiny TLDs with optimized parameters. It seems that the efficiency of the TLDs at the vortex-induced vibration critical wind velocity is significantly higher than that at the design wind velocity. In addition, the parametric studies indicate that the effectiveness of the TLDs is considerably sensitive to the frequency ratio, the height of the TLDs and the mass ratio.
引用
收藏
页数:9
相关论文
共 48 条
  • [41] Effectiveness and robustness of using nonlinear pendulum tuned mass damper inerters for wind-induced vibration mitigation of high-rise buildings
    Yang, Xunchen
    Ma, Ruisheng
    Bi, Kaiming
    Li, Huan
    Du, Xiuli
    STRUCTURES, 2025, 73
  • [42] Wind-induced vibration control and parametric optimization of connected high-rise buildings with tuned liquid-column-damper-inerter
    Wang, Qinhua
    Tian, Huarui
    Qiao, Haoshuai
    Tiwari, Nayan Deep
    Wang, Quan
    ENGINEERING STRUCTURES, 2021, 226
  • [43] Eddy-Current Tuned Mass Dampers for Mitigation of Wind-Induced Response of the Noor III Solar Tower: Design, Installation, and Validation
    Liu, Min
    Li, Shouying
    Wu, Teng
    Li, Yafeng
    Meng, Huachang
    Chen, Zhengqing
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (12)
  • [44] Assessment of wind-induced responses for offshore jacket platforms based on high frequency force balance tests
    Liu, Hongbing
    Chen, Guoming
    Sun, Liping
    Zhu, Benrui
    Huang, Ao
    Zhao, Yipei
    INTERNATIONAL JOURNAL OF OIL GAS AND COAL TECHNOLOGY, 2021, 26 (04) : 357 - 381
  • [45] Intelligent long-term prediction of wind-induced response of super high-rise buildings during typhoons based on wind tunnel tests
    Li, Feiqiang
    Xie, Zhuangning
    Zhang, Lanfang
    Yu, Xianfeng
    Shi, Biqing
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [46] Comparison of stationary and non-stationary wind-induced responses of a super-large cooling tower based on field measurements
    Ke, Shitang
    Wang, Hao
    Ge, Yaojun
    THIN-WALLED STRUCTURES, 2019, 137 : 331 - 346
  • [47] Analysis of vortex induced vibration frequency of super tall building based on wind tunnel tests of MDOF aero-elastic model
    Wang, Lei
    Liang, Shuguo
    Song, Jie
    Wang, Shuliang
    WIND AND STRUCTURES, 2015, 21 (05) : 523 - 536
  • [48] Analysis of vortex induced vibration frequency of super tall building based on wind tunnel tests of MDOF aero-elastic model
    Wang, Lei
    Liang, Shuguo
    Song, Jie
    Wang, Shuliang
    Wind and Structures, An International Journal, 2015, 21 (05): : 523 - 536