Quantification of Cerebral Blood Flow in Healthy Volunteers and Type 1 Diabetic Patients: Comparison of MRI Arterial Spin Labeling and [15O]H2O Positron Emission Tomography (PET)

被引:27
|
作者
van Golen, Larissa W. [1 ]
Kuijer, Joost P. A. [2 ]
Huisman, Marc C. [3 ]
IJzerman, Richard G. [1 ]
Barkhof, Frederik [3 ]
Diamant, Michaela [1 ]
Lammertsma, Adriaan A. [3 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Internal Med, Ctr Diabet, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Phys & Med Technol, NL-1081 HV Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Dept Radiol & Nucl Med, NL-1081 HV Amsterdam, Netherlands
关键词
arterial spin labeling (ASL); cerebral blood flow (CBF); diabetes; O-15]H2O positron emission tomography (PET); GLUCOSE-METABOLISM; GENDER-DIFFERENCES; TC-99M-HMPAO SPET; HIGH-RESOLUTION; INSULIN; PERFUSION; O-15-WATER;
D O I
10.1002/jmri.24484
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare cerebral blood flow (CBF) values measured using magnetic resonance imaging (MRI) arterial spin labeling (ASL) with those obtained with [O-15]H2O positron emission tomography (PET), the gold standard for measuring CBF in vivo. Materials and Methods: Data were collected in 11 healthy men and in 20 age- and body mass index (BMI)-matched type 1 diabetic men. Pseudo-continuous ASL (PCASL) data were acquired at 3 T and [O-15]H2O PET scans were acquired using a high-resolution PET scanner. Input functions were obtained using on-line arterial blood sampling. Whole brain and regional CBF values were compared. Results: For both modalities, whole brain CBF was similar in both subject groups. In groups combined, average whole brain CBF was 0.30 0.05 mL center dot cm(-3)center dot min(-1) for [O-15]H2O PET and 0.34 +/- 0.05 mL center dot cm(-3)center dot min(-1) for ASL MRI (P < 0.01). A significant correlation between methods was observed for whole brain, gray and white matter. In 12 out of 33 brain regions a significant difference between methods was observed. Conclusion: PCASL provides CBF values that correlate with [O-15]H2O PET-derived values, but is less accurate. PCASL may be an attractive alternative when absolute quantification is not needed.J. Magn. Reson. Imaging 2014;40:1300-1309. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1300 / 1309
页数:10
相关论文
共 50 条
  • [21] Parametric renal blood flow imaging using [15O]H2O and PET
    Nobuyuki Kudomi
    Niina Koivuviita
    Kaisa E. Liukko
    Vesa J. Oikonen
    Tuula Tolvanen
    Hidehiro Iida
    Risto Tertti
    Kaj Metsärinne
    Patricia Iozzo
    Pirjo Nuutila
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 683 - 691
  • [22] Comparison between quantitative cardiac magnetic resonance perfusion imaging and [15O]H2O positron emission tomography
    Henk Everaars
    Pepijn A. van Diemen
    Michiel J. Bom
    Stefan P. Schumacher
    Ruben W. de Winter
    Peter M. van de Ven
    Pieter G. Raijmakers
    Adriaan A. Lammertsma
    Mark B. M. Hofman
    Rob J. van der Geest
    Marco J. Götte
    Albert C. van Rossum
    Robin Nijveldt
    Ibrahim Danad
    Roel S. Driessen
    Paul Knaapen
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 1688 - 1697
  • [23] Parametric renal blood flow imaging using [15O]H2O and PET
    Kudomi, Nobuyuki
    Koivuviita, Niina
    Liukko, Kaisa E.
    Oikonen, Vesa J.
    Tolvanen, Tuula
    Iida, Hidehiro
    Tertti, Risto
    Metsarinne, Kaj
    Iozzo, Patricia
    Nuutila, Pirjo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (04) : 683 - 691
  • [24] Comparison of Methods for Quantification of rCBF on the HRRT PET Scanner Using [15O]H2O
    Walker, Matthew D.
    Feldmann, Maria
    Anton-Rodriguez, Jose M.
    Wang, Shaonan
    Matthews, Julian C.
    Koepp, Matthias J.
    Asselin, Marie-Claude
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2966 - 2971
  • [25] Simultaneous evaluation of myocardial blood flow, cardiac function and lung water content using [15O]H2O and positron emission tomography
    Naum, Alexandru
    Tuunanen, Helena
    Engblom, Erik
    Oikonen, Vesa
    Sipilae, Hannu
    Iozzo, Patricia
    Nuutila, Pirjo
    Knuuti, Juhani
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (04) : 563 - 572
  • [26] Simultaneous evaluation of myocardial blood flow, cardiac function and lung water content using [15O]H2O and positron emission tomography
    Alexandru Naum
    Helena Tuunanen
    Erik Engblom
    Vesa Oikonen
    Hannu Sipilä
    Patricia Iozzo
    Pirjo Nuutila
    Juhani Knuuti
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 563 - 572
  • [27] Comparison of Global Cerebral Blood Flow Measured by Phase-Contrast Mapping MRI with 15O-H2O Positron Emission Tomography
    Vestergaard, Mark Bitsch
    Lindberg, Ulrich
    Aachmann-Andersen, Niels Jacob
    Lisbjerg, Kristian
    Christensen, Soren Just
    Rasmussen, Peter
    Olsen, Niels Vidiendal
    Law, Ian
    Larsson, Henrik Bo Wiberg
    Henriksen, Otto Molby
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (03) : 692 - 699
  • [28] THE PROGNOSTIC VALUE OF [15O]H2O POSITRON EMISSION TOMOGRAPHY DERIVED MYOCARDIAL ISCHEMIC BURDEN
    Van Diemen, Pepijn
    Wijmenga, Jan-Thijs
    Driessen, Roel
    Bom, Michiel
    Schumacher, Stefan
    Stuijfzand, Wynand
    Raijmakers, Pieter
    Everaars, Henk
    De Winter, Ruben
    van de Ven, Peter
    van Rossum, Albert
    Danad, Ibrahim
    Knaapen, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1798 - 1798
  • [29] Cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking after acute stroke in pigs -: Comparison with [15O]H2O positron emission tomography -: Editorial comment
    Knight, RA
    STROKE, 2000, 31 (08) : 1964 - 1964
  • [30] Quantitative Cerebral Perfusion Imaging in Children and Young Adults with Moyamoya Disease: Comparison of Arterial Spin-Labeling-MRI and H2[15O]-PET
    Goetti, R.
    Warnock, G.
    Kuhn, F. P.
    Guggenberger, R.
    O'Gorman, R.
    Buck, A.
    Khan, N.
    Scheer, I.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (05) : 1022 - 1028