Evaluation of SIRIUS retinal vessel width measurement in REVIEW dataset

被引:0
|
作者
Vazquez, S. G. [1 ]
Barreira, N. [1 ]
Penedo, M. G. [1 ]
Pena-Seijo, M. [2 ]
Gomez-Ulla, F. [3 ]
机构
[1] Univ A Coruna, Dept Comp Sci, Varpa Grp, La Coruna, Spain
[2] Univ Hosp Santiago, Internal Med, Santiago De Compostela, Spain
[3] Technol Inst Ophthalmol, Santiago De Compostela, Spain
关键词
RETINOPATHY; RISK; SET;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper focuses on evaluating a method for measuring the retinal vessel widths in a recently publicly available database (REVIEW). The algorithm is based on deformable models and it constitutes an essential step in a methodology to compute the AVR automatically. This methodology is part of a web-based framework aimed to integrate diverse techniques in the field of retinal image analysis. The results achieved in the REVIEW database indicate the method is comparable or, in some cases, improves the accuracy of other techniques for measuring the vessel widths.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [31] Width Attention based Convolutional Neural Network for Retinal Vessel Segmentation
    Alvarado-Carrillo, Dora E.
    Dalmau-Cedeno, Oscar S.
    [J]. EXPERT SYSTEMS WITH APPLICATIONS, 2022, 209
  • [32] Change in Retinal Vessel Width and Tortuosity in Eyes at Risk for Retinopathy of Prematurity
    Ghodasra, D. H.
    Thuangtong, A.
    Karp, K.
    Ying, G. -S.
    Mills, M.
    Wilson, C. M.
    Fielder, A. R.
    Ng, J.
    Quinn, G. E.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] RETINAL VESSEL WIDTH MEASUREMENTS BASED ON A GRAPH-THEORETIC METHOD
    Xu, X.
    Niemeijer, M.
    Song, Q.
    Garvin, M. K.
    Reinhardt, J. M.
    Abramoff, M. D.
    [J]. 2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 641 - 644
  • [34] Short-term correlation of retinal vessel width and blood pressure
    Rieger, S.
    Baumgarten, D.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S216 - S216
  • [35] Measurement of retinal vessel diameters in images produced by the Heidelberg retinal tomograph
    Joos, K
    Singleton, C
    Shen, J
    [J]. OPHTHALMIC TECHNOLOGIES VII, PROCEEDINGS OF, 1997, 2971 : 35 - 39
  • [36] MEASUREMENT OF APPARENT VESSEL WIDTH IN FLUORESCENCE ANGIOGRAPHY OF FUNDUS OCULI
    GRIFFITHS, JD
    HILL, DW
    YOUNG, S
    [J]. OPHTHALMIC RESEARCH, 1974, 6 (01) : 1 - 5
  • [37] Recent Techniques and Trends for Retinal Blood Vessel Extraction and Tortuosity Evaluation: A Comprehensive Review
    Krestanova, Alice
    Kubicek, Jan
    Penhaker, Marek
    [J]. IEEE ACCESS, 2020, 8 : 197787 - 197816
  • [38] ROSE: A Retinal OCT-Angiography Vessel Segmentation Dataset and New Model
    Ma, Yuhui
    Hao, Huaying
    Xie, Jianyang
    Fu, Huazhu
    Zhang, Jiong
    Yang, Jianlong
    Wang, Zhen
    Liu, Jiang
    Zheng, Yalin
    Zhao, Yitian
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (03) : 928 - 939
  • [39] Novel Computerized Method for Measurement of Retinal Vessel Diameters
    Guedri, Hichem
    Ben Abdallah, Mariem
    Echouchene, Fraj
    Belmabrouk, Hafedh
    [J]. BIOMEDICINES, 2017, 5 (02)
  • [40] Retinal Vessel Oxygen Saturation Measurement Protocols and Their Agreement
    Heitmar, Rebekka
    Cubbidge, Robert P.
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (06): : 1 - 9