Commissioning of Advanced Collapsed Cone Engine Algorithm for Brachytherapy

被引:0
|
作者
Swamidas, J. [1 ]
Parida, S. [1 ]
Joshi, K. [1 ]
Phurailatpam, R. [1 ]
Panda, S. [1 ]
Pradhan, S. [1 ]
机构
[1] Tata Mem Hosp, ACTREC, Dept Radiat Oncol, Navi Mumbai, Maharashtra, India
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
WE-C1030-G
引用
收藏
页码:E447 / E447
页数:1
相关论文
共 50 条
  • [31] Advanced Collapsed cone Engine dose calculations in tissue media for COMS eye plaques loaded with I-125 seeds
    Morrison, Hali
    Menon, Geetha
    Larocque, Matthew P.
    van Veelen, Bob
    Niatsetski, Yury
    Weis, Ezekiel
    Sloboda, Ron S.
    [J]. MEDICAL PHYSICS, 2018, 45 (07) : 3349 - 3360
  • [32] Validation of a Commercial Model-Based Collapsed Cone Dose Algorithm for High Dose-Rate Gynecological Brachytherapy Treatment Planning
    Price, M. J.
    Fontenot, J. D.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [33] Dosimetric test of collapsed cone convolution superposition algorithm in a heterogeneous media
    Oliveira e Silva, L. F.
    Mangueira, T. F.
    Dias, J. R.
    Avelino, S. R.
    [J]. EUROPEAN JOURNAL OF CANCER, 2013, 49 : S231 - S232
  • [34] Dosimetric verification of a commercial collapsed cone algorithm in simulated clinical situations
    Nisbet, A
    Beange, I
    Vollmar, HS
    Irvine, C
    Morgan, A
    Thwaites, DI
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 (01) : 79 - 88
  • [35] Accounting for high Z shields in brachytherapy using collapsed cone superposition for scatter dose calculation
    Tedgren, ÅKC
    Ahnesjö, A
    [J]. MEDICAL PHYSICS, 2003, 30 (08) : 2206 - 2217
  • [36] Initial evaluation of Advanced Collapsed cone Engine dose calculations in water medium for I-125 seeds and COMS eye plaques
    Morrison, Hali
    Menon, Geetha
    Larocque, Matthew P.
    van Veelen, Bob
    Niatsetski, Yury
    Weis, Ezekiel
    Sloboda, Ron S.
    [J]. MEDICAL PHYSICS, 2018, 45 (03) : 1276 - 1286
  • [37] Collapsed cone dose calculations for heterogeneous tissues in brachytherapy using primary and scatter separation source data
    Ahnesjo, Anders
    van Veelen, Bob
    Tedgren, Asa Carlsson
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 139 : 17 - 29
  • [38] Validation of the oncentrabrachy collapsed cone convolution algorithm using real patient geometries
    Ma, Y.
    Lacroix, F.
    Lavallee, M. C.
    Beaulieu, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S15 - S15
  • [39] Commissioning of applicator-guided SBRT with HDR Brachytherapy for Advanced Cervical Cancer
    Aldelaijan, S.
    Wadi-Ramahi, S.
    Nobah, A.
    Jastaniyah, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S193 - S194
  • [40] Evaluation of the RadCalc collapsed cone dose calculation algorithm against measured data
    Richmond, Neil
    Chester, Katherine
    Manley, Steven
    [J]. MEDICAL DOSIMETRY, 2023, 48 (04) : 216 - 224