Low-coherence optical fibre speckle interferometry

被引:12
|
作者
Balboa, I. [1 ]
D Ford, H. [1 ]
Tatam, R. P. [1 ]
机构
[1] Cranfield Univ, Opt Sensors Grp, Ctr Photon & Opt Engn, Sch Engn, Cranfield MK43 0AL, Beds, England
关键词
low-coherence; speckle interferometry; profilometry; shape measurement;
D O I
10.1088/0957-0233/17/4/001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes the development of optical fibre low-coherence speckle interferometers capable of three-dimensional surface profiling with a resolution of 10-20 mu m and a depth range of typically tens of centimetres. The technique is absolute, enabling the measurement of steps and through holes. The inclusion of optical fibres enables compact, flexible configurations to be realized, alleviating the experimental difficulties encountered with bulk interferometers, particularly when using long path lengths for measurements on large test objects. Sources including light-emitting and superluminescent diodes and multimode laser diodes are compared, and the use of a multimode laser diode Source in pulsed mode is shown to improve depth resolution. Fibre-based systems using both single mode and polarization-maintaining fibre are described, and the results of experimental measurements on a stepped test object, a tilted plate and a coin are presented. A depth resolution of +/- 20 mu m is obtained for the standard fibre system and +/- 14 mu m for the system based on polarization-maintaining fibre.
引用
收藏
页码:605 / 616
页数:12
相关论文
共 50 条
  • [21] Radio-frequency low-coherence interferometry
    Fernandez-Pousa, Carlos R.
    Mora, Jose
    Maestre, Haroldo
    Corral, Pablo
    [J]. OPTICS LETTERS, 2014, 39 (12) : 3634 - 3637
  • [22] Light source for low-coherence interferometry and imaging
    Sverdlov, MI
    Akchurin, GG
    Alaverdyan, SA
    Andrushkevich, TA
    Zimnyakov, DA
    Kuznetsova, OA
    Mishin, AA
    Mikaelyan, GT
    Sokolov, SN
    Stepuhovich, AV
    Tuchin, VV
    [J]. COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS II, PROCEEDINGS OF, 1998, 3251 : 273 - 277
  • [23] Semiconductor line source for low-coherence interferometry
    Zvyagin, AV
    Garcia-Webb, MG
    Sampson, DD
    [J]. APPLIED OPTICS, 2001, 40 (06) : 913 - 915
  • [24] MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY
    HITZENBERGER, CK
    [J]. APPLIED OPTICS, 1992, 31 (31): : 6637 - 6642
  • [25] Self-mixing low-coherence interferometry
    Rovati, L
    Musatti, G
    Docchio, F
    [J]. BIOMEDICAL SYSTEMS AND TECHNOLOGIES II, PROCEEDINGS OF, 1998, 3199 : 268 - 272
  • [26] Ultraprecise measurement of low-coherence interferometry spectrum
    Zhang, Xuezhi
    Liu, Tiegen
    Jiang, Junfeng
    Liu, Kun
    [J]. 2013 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SENSORS AND APPLICATIONS, 2013, 9044
  • [27] Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry
    Huang, Jinhai
    McAlinden, Colm
    Huang, Yingying
    Wen, Daizong
    Savini, Giacomo
    Tu, Ruixue
    Wang, Qinmei
    [J]. SCIENTIFIC REPORTS, 2017, 7 : 1 - 10
  • [28] LOW-COHERENCE INTERFEROMETRY IN CORONARY-ARTERIES
    CHORNENKY, VI
    [J]. CORONARY ARTERY DISEASE, 1995, 6 (05) : 377 - 380
  • [29] Characterization of random media by low-coherence interferometry
    Thurber, SR
    Brodsky, AM
    Burgess, LW
    [J]. APPLIED SPECTROSCOPY, 2000, 54 (10) : 1506 - 1514
  • [30] Applications of low-coherence interferometry in fiber optics
    Hlubina, P
    [J]. LIGHTMETRY: METROLOGY, SPECTROSCOPY, AND TESTING TECHNIQUES USING LIGHT, 2001, 4517 : 259 - 266