Fingerprinting postblast explosive residues by portable capillary electrophoresis with contactless conductivity detection

被引:32
|
作者
Kobrin, Eeva-Gerda [1 ]
Lees, Heidi [1 ]
Fomitsenko, Maria [1 ]
Kuban, Petr [1 ,2 ]
Kaljurand, Mihkel [1 ]
机构
[1] Tallinn Univ Technol, Dept Chem, EE-12618 Tallinn, Estonia
[2] Masaryk Univ, Dept Chem, Brno, Czech Republic
关键词
Capillary electrophoresis; Contactless conductivity detection; Explosives; Simultaneous separation of anions and cations; Principal component analysis; SIMULTANEOUS SEPARATION; INORGANIC ANIONS; IDENTIFICATION; CATIONS; ELECTROPHEROGRAPH; INSTRUMENTATION; DEVICES; AGENTS;
D O I
10.1002/elps.201300380
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A portable capillary electrophoretic system with contactless conductivity detection was used for fingerprint analysis of postblast explosive residues from commercial organic and improvised inorganic explosives on various surfaces (sand, concrete, metal witness plates). Simple extraction methods were developed for each of the surfaces for subsequent simultaneous capillary electrophoretic analysis of anions and cations. Dual-opposite end injection principle was used for fast (<4 min) separation of 10 common anions and cations from postblast residues using an optimized separation electrolyte composed of 20 mM MES, 20 mM l-histidine, 30 M CTAB and 2 mM 18-crown-6. The concentrations of all ions obtained from the electropherograms were subjected to principal component analysis to classify the tested explosives on all tested surfaces, resulting in distinct cluster formations that could be used to verify (each) type of the explosive.
引用
收藏
页码:1165 / 1172
页数:8
相关论文
共 50 条
  • [31] Determination of mono- and disaccharides by capillary electrophoresis with contactless conductivity detection
    Carvalho, AZ
    da Silva, JAF
    do Lago, CL
    ELECTROPHORESIS, 2003, 24 (12-13) : 2138 - 2143
  • [32] Capillary and microchip electrophoresis with contactless conductivity detection for analysis of foodstuffs and beverages
    Tuma, Petr
    Opekar, Frantisek
    Dlouhy, Pavel
    FOOD CHEMISTRY, 2022, 375
  • [33] Determination of tobramycin in human serum by capillary electrophoresis with contactless conductivity detection
    Law, Wai Siang
    Kuban, Pavel
    Yuan, Ling Ling
    Zhao, Jian Hong
    Li, Sam Fong Yau
    Hauser, Peter C.
    ELECTROPHORESIS, 2006, 27 (10) : 1932 - 1938
  • [34] Application of capillary electrophoresis with capacitively contactless conductivity detection for biomedical analysis
    Elbashir, Abdalla A.
    Osman, Abdelbagi
    Elawad, Mohammed
    Ziyada, Abobakr K.
    Aboul-Enein, Hassan Y.
    ELECTROPHORESIS, 2024, 45 (5-6) : 400 - 410
  • [35] Separation of fluoroquinolones in acidic buffer by capillary electrophoresis with contactless conductivity detection
    Yang, Zhongju
    Qin, Weidong
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (27) : 5327 - 5332
  • [36] CAPILLARY ELECTROPHORESIS WITH CONTACTLESS CONDUCTIVITY DETECTION OF CATIONIC-DERIVATIZED OLIGOSACCHARIDES
    Partyka, Jan
    Foret, Frantisek
    CECE 2012: 9TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2012, : 27 - 29
  • [37] Optimization of separation of heavy metals by capillary electrophoresis with contactless conductivity detection
    Lau, Hiu Fung
    Quek, Ngee Mian
    Law, Wai Siang
    Zhao, Jian Hong
    Hauser, Peter C.
    Li, Sam Fong Yau
    ELECTROPHORESIS, 2011, 32 (10) : 1190 - 1194
  • [38] Determination of salbutamol sulfate in medicaments by capillary electrophoresis with contactless conductivity detection
    Chen Changguo
    Li Hong
    Fan Yujing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (02) : 137 - 140
  • [39] Pushing the Limits of Capacitively Coupled Contactless Conductivity Detection for Capillary Electrophoresis
    Li, Lin
    Ren, Dou-Dou
    Zhang, Peng-Yu
    Song, Yun-Peng
    Li, Tang-Xiu
    Gao, Ming-Hui
    Xu, Jia-Nan
    Zhou, Lei
    Zeng, Zhi-Cong
    Pu, Qiaosheng
    ANALYTICAL CHEMISTRY, 2024, 96 (25) : 10356 - 10364
  • [40] Field-portable capillary electrophoresis instrument with conductivity detection
    Zhang, H. F.
    Liu, X. W.
    Wang, W.
    Wang, X. L.
    Tian, L.
    4th International Symposium on Instrumentation Science and Technology (ISIST' 2006), 2006, 48 : 725 - 729