Accuracy and repeatability of joint angles measured using a single camera markerless motion capture system

被引:113
|
作者
Schmitz, Anne [1 ]
Ye, Mao [2 ]
Shapiro, Robert [3 ]
Yang, Ruigang [2 ]
Noehren, Brian [1 ]
机构
[1] Univ Kentucky, Div Phys Therapy, Lexington, KY 40506 USA
[2] Univ Kentucky, Dept Comp Sci, Lexington, KY 40506 USA
[3] Univ Kentucky, Dept Kinesiol & Hlth Promot, Lexington, KY 40506 USA
基金
美国国家科学基金会;
关键词
Microsoft Kinect; Motion capture; Accuracy and reliability; Joint angles; MICROSOFT KINECT; GAIT; RELIABILITY; KINEMATICS; VALIDITY; KNEE; RUNNERS; ERRORS;
D O I
10.1016/j.jbiomech.2013.11.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Markerless motion capture systems have developed in an effort to evaluate human movement in a natural setting. However, the accuracy and reliability of these systems remain understudied. Therefore, the goals of this study were to quantify the accuracy and repeatability of joint angles using a single camera markerless motion capture system and to compare the markerless system performance with that of a marker-based system. A jig was placed in multiple static postures with marker trajectories collected using a ten camera motion analysis system. Depth and color image data were simultaneously collected from a single Microsoft Kinect camera, which was subsequently used to calculate virtual marker trajectories. A digital inclinometer provided a measure of ground-truth for sagittal and frontal plane joint angles. Joint angles were calculated with marker data from both motion capture systems using successive body-fixed rotations. The sagittal and frontal plane joint angles calculated from the marker-based and markerless system agreed with inclinometer measurements by < 0.5 degrees. The systems agreed with each other by <0.5 degrees for sagittal and frontal plane joint angles and <2 degrees for transverse plane rotation. Both systems showed a coefficient of reliability <0.5 degrees for all angles. These results illustrate the feasibility of a single camera markerless motion capture system to accurately measure lower extremity kinematics and provide a first step in using this technology to discern clinically relevant differences in the joint kinematics of patient populations. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:587 / 591
页数:5
相关论文
共 50 条
  • [31] KINEMATIC DIFFERENCES BETWEEN THE FLAT, KICK AND SLICE SERVES MEASURED USING A MARKERLESS MOTION CAPTURE METHOD
    Sheets, Alison L.
    Corazza, Stefano
    Abrams, Geoff
    Safran, Marc
    Andriacchi, Thomas
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 195 - 196
  • [32] Kinematics Differences Between the Flat, Kick, and Slice Serves Measured Using a Markerless Motion Capture Method
    Sheets, Alison L.
    Abrams, Geoffrey D.
    Corazza, Stefano
    Safran, Marc R.
    Andriacchi, Thomas P.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (12) : 3011 - 3020
  • [33] Evaluation of 3D Markerless Motion Capture System Accuracy during Skate Skiing on a Treadmill
    Torvinen, Petra
    Ruotsalainen, Keijo S.
    Zhao, Shuang
    Cronin, Neil
    Ohtonen, Olli
    Linnamo, Vesa
    [J]. BIOENGINEERING-BASEL, 2024, 11 (02):
  • [34] Assessment of Hip and Lumbar Spine Range of Motion After Total Hip Arthroplasty Using a Single Camera Markerless System
    Roustemis, Anastasios G.
    Gavriil, Panagiotis
    Skouras, Apostolos Z.
    Melissaridou, Dimitra
    Sioutis, Spyridon
    Trikoupis, Ioannis
    Karampikas, Vasileios
    Avgerinos, Konstantinos
    Altsitzioglou, Pavlos
    Koulouvaris, Panagiotis
    Papagelopoulos, Panayiotis J.
    Savvidou, Olga
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [35] Kinematics Differences Between the Flat, Kick, and Slice Serves Measured Using a Markerless Motion Capture Method
    Alison L. Sheets
    Geoffrey D. Abrams
    Stefano Corazza
    Marc R. Safran
    Thomas P. Andriacchi
    [J]. Annals of Biomedical Engineering, 2011, 39 : 3011 - 3020
  • [36] A single camera motion capture system for human-computer interaction
    Okada, Ryuzo
    Stenger, Bjoern
    [J]. IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2008, E91D (07): : 1855 - 1862
  • [37] Joint Moments And Powers Variability Estimated By Markerless Motion Capture System May Affect Clinical Interpretations
    Tang, Hui
    Li, Li
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 987 - 988
  • [38] Most favorable camera configuration for a shape-from-silhouette markerless motion capture system for biomechanical analysis
    Mündermann, L
    Corazza, S
    Chaudhari, AM
    Alexander, EJ
    Andriacchi, TP
    [J]. VIDEOMETRICS VIII, 2005, 5665 : 278 - 287
  • [39] Camera Rig Extrinsic Calibration Using a Motion Capture System
    Chiodini, Sebastiano
    Pertile, Marco
    Giubilato, Riccardo
    Salvioli, Federico
    Barrera, Marco
    Franceschetti, Paola
    Debei, Stefano
    [J]. 2018 5TH IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (METROAEROSPACE), 2018, : 590 - 595
  • [40] Kinematics of the Tennis Serve Using an Optoelectronic Motion Capture System: Are There Correlations between Joint Angles and Racket Velocity?
    Jacquier-Bret, Julien
    Gorce, Philippe
    [J]. SENSORS, 2024, 24 (11)