Method of localized removal of cells using a bolt-clamped Langevin transducer with an ultrasonic horn

被引:13
|
作者
Inui, Takumi [1 ]
Kurashina, Yuta [2 ,3 ]
Imashiro, Chikahiro [1 ]
Takemura, Kenjiro [2 ]
机构
[1] Keio Univ, Sch Sci Open & Environm Syst, Grad Sch Sci & Technol, Yokohama, Kanagawa, Japan
[2] Keio Univ, Dept Mech Engn, Fac Sci & Technol, Yokohama, Kanagawa, Japan
[3] Tokyo Inst Technol, Sch Mat & Chem Technol, Yokohama, Kanagawa, Japan
来源
ENGINEERING IN LIFE SCIENCES | 2019年 / 19卷 / 08期
基金
日本学术振兴会;
关键词
cell culture efficiency; cell elimination; induced pluripotent stem cells; Langevin transducer; ultrasonic waves; RESONANCE VIBRATION; TERATOMA FORMATION;
D O I
10.1002/elsc.201800173
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cell isolation by eliminating undesirable cell aggregations or colonies with low activity is essential to improve cell culture efficiency. Moreover, when creating tissues from induced pluripotent stem cells, residual undifferentiated cells must be removed to prevent tumor formation in vivo. Here, we evaluated the use of ultrasonic irradiation, which can apply energy locally without contact, and proposed a method to eliminate cells in a small area of culture by ultrasonic irradiation from a Langevin transducer. We constructed a device that incorporated a bolt-clamped 19.84 kHz Langevin transducer with an ultrasonic horn and determined the optimal conditions for stable elimination of cells in small areas of a 35-mm culture dish. The optimal conditions were as follows: number of cycles = 400, clearance distance = 1 mm, volume of medium = 4 mL, and distance from the center of culture surface = 0 mm. The mean cell elimination area under these conditions was 0.097 mm(2). We also evaluated the viability of neighboring cells after ultrasonic irradiation by fluorescent staining and found that most cells around the elimination area survived. These findings suggest that the proposed method has potential for localized elimination of cells without the need for contact with the cell surface.
引用
收藏
页码:575 / 583
页数:9
相关论文
共 50 条
  • [1] Design and construction of a bolt-clamped Langevin transducer
    Moreno, E
    Acevedo, P
    Fuentes, M
    Sotomayor, A
    Borroto, L
    Villafuerte, ME
    Leija, L
    2005 2nd International Conference on Electrical & Electronics Engineering (ICEEE), 2005, : 393 - 395
  • [2] An ultrasonic motor for cryogenic temperature using bolt-clamped Langevin-type transducer
    Yamaguchi, Daisuke
    Kanda, Takefumi
    Suzumori, Koichi
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 184 : 134 - 140
  • [3] Effects of impulse forces on electrical characteristics of bolt-clamped Langevin ultrasonic transducer
    Chang, Kuo-Tsai
    2005 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY - (ICIT), VOLS 1 AND 2, 2005, : 957 - 962
  • [4] CHARACTERISTICS OF BOLT-CLAMPED LANGEVIN TYPE ULTRASONIC TRANSDUCER WITH SQUARE RADIATING SURFACE
    YAMAMORI, H
    ITO, T
    OHYA, K
    BANNO, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1990, 29 : 167 - 169
  • [5] Ultrasonic linear motor using longitudinal and bending multimode bolt-clamped langevin type transducer
    School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 18 (30-34): : 30 - 34
  • [6] Experimental method for vibration analysis of a bolt-clamped ultrasonic transducer
    Kim, Jungsoon
    Kim, Moojoon
    ACOUSTICAL SCIENCE AND TECHNOLOGY, 2023, 44 (01) : 1 - 8
  • [7] Suggestion of an experimental method for optimization of flange point of a bolt-clamped Langevin-type ultrasonic transducer
    Kim, Jungsoon
    Kim, Haeun
    Kim, Moojoon
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2021, 40 (04): : 270 - 277
  • [8] Bolt-Clamped Langevin-Type Transducer for Ultrasonic Motor used at Ultralow Temperature
    Yamaguchi, Daisuke
    Kanda, Takefumi
    Suzumori, Koichi
    JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2012, 6 (01): : 104 - 112
  • [9] Improving the transient response of a bolt-clamped Langevin transducer using a parallel resistor
    Chang, KT
    ULTRASONICS, 2003, 41 (06) : 427 - 436
  • [10] Compact aerial ultrasonic source integrating the transverse vibration part with the bolt-clamped Langevin transducer
    Ohfuchi, Ryota
    Kasashima, Takashi
    Itoh, Shinsuke
    Asami, Takuya
    Miura, Hikaru
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2023, 62 (SJ)