Bolt-Clamped Langevin-Type Transducer for Ultrasonic Motor used at Ultralow Temperature

被引:15
|
作者
Yamaguchi, Daisuke [1 ]
Kanda, Takefumi [1 ]
Suzumori, Koichi [1 ]
机构
[1] Okayama Univ, Grad Sch Nat Sci & Technol, Kita Ku, Okayama, Japan
关键词
Ultralow Temperature; Ultrasonic Motor; Piezoelectric Transducer; Actuator; Thermal Stress; ELECTRON-MICROSCOPY;
D O I
10.1299/jamdsm.6.104
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ultralow temperature environments are important for advanced scientific research areas, for example, chemical analysis technology. Some devices need to be operated in an ultralow temperature environment. However, actuators used in such an environment have low output power. As a result, some applications in an ultralow temperature environment have limited functions. This research aims to achieve a piezoelectric actuator having high output power at an ultralow temperature. A bolt-clamped Langevin-type transducer for an ultrasonic motor used in an ultralow temperature environment is proposed. The piezoelectric materials used in the transducer are affected by thermal stress when the temperature decreases from room temperature to an ultralow one. As a result, the materials break down or the performance of the transducer decreases. Thermal stress was simulated with the finite element method using some non-linear properties of materials in the transducer. The influence of the stress was evaluated by driving a transducer at an ultralow temperature obtained by using helium gas. An ultrasonic motor for use at an ultralow temperature was fabricated and evaluated. The maximum diameter and the height of the motor are 22 and 30.5 mm, respectively. The motor was successfully rotated at an ultralow temperature.
引用
收藏
页码:104 / 112
页数:9
相关论文
共 50 条
  • [1] An ultrasonic motor for cryogenic temperature using bolt-clamped Langevin-type transducer
    Yamaguchi, Daisuke
    Kanda, Takefumi
    Suzumori, Koichi
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 184 : 134 - 140
  • [2] Suggestion of an experimental method for optimization of flange point of a bolt-clamped Langevin-type ultrasonic transducer
    Kim, Jungsoon
    Kim, Haeun
    Kim, Moojoon
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2021, 40 (04): : 270 - 277
  • [3] Droplets generation by a torsional bolt-clamped Langevin-type transducer and micropore plate
    Harada, Takuya
    Ishikawa, Naoyuki
    Kanda, Takefumi
    Suzumori, Koichi
    Yamada, Yoshiaki
    Sotowa, Ken-Ichiro
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 627 - +
  • [4] Experimental evaluation of the static strain on the clamping bolt in the structure of a bolt-clamped Langevin-type transducer
    Takahashi, Toru
    Adachi, Kazunari
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (06) : 4736 - 4741
  • [5] Development of a bolt-clamped Langevin-type transducer for operation at a high frequency of 80 kHz
    Adachi, K
    Hasegawa, H
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 661 - 664
  • [6] Improvement of the low speed controllability of a V-shaped, two bolt-clamped Langevin-type transducer, ultrasonic linear motor
    Asumi, K.
    Fujimura, T.
    Fukunaga, R.
    Kurosawa, M. K.
    2007 INTERNATIONAL SYMPOSIUM ON MICRO-NANO MECHATRONICS AND HUMAN SCIENCE, VOLS 1 AND 2, 2007, : 377 - +
  • [7] Elastic contact problem of the piezoelectric material in the structure of a bolt-clamped Langevin-type transducer
    Adachi, K
    Tsuji, M
    Kato, H
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03): : 1651 - 1656
  • [8] Core-Shell Droplet Generation Device Using a Flexural Bolt-Clamped Langevin-Type Ultrasonic Transducer
    Omori, Kentaro
    Fujimoto, Nozomu
    Kanda, Takefumi
    Wakimoto, Shuichi
    Seno, Norihisa
    ACTUATORS, 2021, 10 (03)
  • [9] Ultrasonic linear motor using longitudinal and bending multimode bolt-clamped langevin type transducer
    School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
    Zhongguo Dianji Gongcheng Xuebao, 2007, 18 (30-34): : 30 - 34
  • [10] Ultraprecision XY stage using a hybrid bolt-clamped Langevin-type ultrasonic linear motor for continuous motion
    Lee, Dong-Jin
    Lee, Sun-Kyu
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (01):