Optimization of the wall thermal insulation characteristics based on the intermittent heating operation

被引:35
|
作者
Meng, Xi [1 ]
Huang, Yuqiu [1 ]
Cao, Ying [1 ]
Gao, Yanna [1 ]
Hou, Chaoping [1 ]
Zhang, Lili [1 ]
Shen, Qiong [1 ]
机构
[1] Sichuan Agr Univ, Coll Architecture & Urban Rural Planning, Chengdu 610065, Peoples R China
关键词
Thermal response rate; Inner surface heat flow; Intermittent heating operation; Thermal insulation form;
D O I
10.1016/j.cscm.2018.e00188
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The intermittent heating operation is used widely, but the heating behavior status is always ignored to simplify the energy conservation design in the present optimization of thermal insulation characteristics and then the heating equipment is assumed to run. To optimize wall thermal insulation characteristics under the intermittent heating operation, six typically-employed walls of different thermal insulation forms were built to analyze the effect of thermal insulation forms on thermal response rate and heat flow in the inner surface comparatively. The comparative results showed that the interior insulation wall and the foamed concrete wall were the most suitable for the intermittent heating condition, while the exterior insulation wall and the self-insulation concrete wall would be relatively poor choices. The interior insulation wall and the foamed concrete wall had the highest thermal response rate and the highest surface temperature, 3 degrees C-10 degrees C higher than the other insulation wall examined, while they had the lowest values of inner surface heat flows, 26.8%-50.3% less than the other insulation wall. (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Thermal performance based optimization of an office wall containing PCM under intermittent cooling operation
    Tuncbilek, Ekrem
    Arici, Muslum
    Krajcik, Michal
    Nizetic, Sandro
    Karabay, Hasan
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [2] Characteristics optimization of composite phase-change wall during intermittent heating process
    Li, Yanru
    Long, Enshen
    Ding, Pei
    Guo, Shurui
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (04) : 541 - 551
  • [3] Effect of the thermal insulation layer location on wall dynamic thermal response rate under the air-conditioning intermittent operation
    Zhang, Lili
    Luo, Tao
    Meng, Xi
    Wang, Yating
    Hou, Chaoping
    Long, Enshen
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 79 - 85
  • [4] Influence of the Building's Thermal Insulation on Intermittent Heating Mode Efficiency
    Balasanian, Hennadii
    Klymchuk, Oleksandr
    Luzhanska, Ganna
    Aksyonova, Inna
    Voronenko, Serhii
    MANAGEMENT SYSTEMS IN PRODUCTION ENGINEERING, 2024, 32 (04) : 484 - 488
  • [5] Optimization of Wall Thickness Based on a Comprehensive Evaluation Index of Thermal Mass and Insulation
    Yu, Shenwei
    Hao, Shimeng
    Mu, Jun
    Tian, Dongwei
    SUSTAINABILITY, 2022, 14 (03)
  • [6] Comparative analysis on thermal performance of different wall insulation forms under the air-conditioning intermittent operation in summer
    Meng, Xi
    Luo, Tao
    Gao, Yanna
    Zhang, Lili
    Huang, Xing
    Hou, Chaoping
    Shen, Qiong
    Long, Enshen
    APPLIED THERMAL ENGINEERING, 2018, 130 : 429 - 438
  • [7] A NEW METHOD FOR THE OPTIMIZATION OF INSULATION THICKNESS FOR RADIANT WALL HEATING SYSTEMS
    Koca, Aliihsan
    Cetin, Gursel
    Velisan, Eser
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 37 (02) : 75 - 88
  • [8] Simulation of Heating & Cooling Load of Rooms of Brick Wall Houses on Intermittent Operation
    Matsumoto, Narumi
    Fukuda, Hiroatsu
    Kuma, Yuko
    6TH INTERNATIONAL SYMPOSIUM OF ASIA INSTITUTE OF URBAN ENVIRONMENT: ENERGY CONSERVATION AND CARBON OFF IN ASIA CITY, 2009, : 308 - 311
  • [9] Evaluation of Thermal Insulation Performance of Building Exterior Wall Based on Multiobjective Optimization Algorithm
    Liang, Dong
    Jing, Feng
    MOBILE INFORMATION SYSTEMS, 2022, 2022
  • [10] OPTIMIZATION OF INTERMITTENT HEATING
    BLOOMFIELD, DP
    FISK, DJ
    BUILDING AND ENVIRONMENT, 1977, 12 (01) : 43 - 55