Comparative analysis on thermal performance of different wall insulation forms under the air-conditioning intermittent operation in summer

被引:44
|
作者
Meng, Xi [1 ]
Luo, Tao [2 ]
Gao, Yanna [1 ]
Zhang, Lili [1 ]
Huang, Xing [1 ]
Hou, Chaoping [1 ]
Shen, Qiong [1 ]
Long, Enshen [3 ]
机构
[1] Sichuan Agr Univ, Coll Architectural & Urban Rural Planning, Dujiangyan, Sichuan, Peoples R China
[2] Minist Agr, Biogas Inst, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Sichuan, Peoples R China
关键词
Wall insulation structures; Intermittent operation; Continuous operation; Energy efficiency; OPTIMAL TEMPERATURE CONTROL; FLOW METER METHOD; PREDICTIVE CONTROL; STRUCTURAL WALLS; HEAT-TRANSFER; BUILDINGS; TIME; COEFFICIENT;
D O I
10.1016/j.applthermaleng.2017.11.042
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning intermittent operation is widely applied in building daily management, but more attention is focused on the air-conditioning continuous operation to simplify the energy-saving design. And the air-conditioning operation difference between the daily use and the energy-saving design must lead to large discrepancies in the energy efficiency and energy consumption between the actual usage and the primary design. Taking into account this situation, a verified numerical simulation was carried on to comparatively analyze the thermal performance of different wall insulation forms under air-conditioning intermittent and continuous operation in summer. The numerical results showed that the different wall insulation forms had a remarkable effect on the temperature response rate and the heat flow of the inner surface under the air-conditioning intermittent operation, although they had the same heat transfer coefficients. The interior insulation was more suitable for the wall insulation form under air-conditioning intermittent operation, while the heavyweight self-insulation and exterior insulation were more suitable under air-conditioning continuous operation. Compared with the air-conditioning continuous operation, the daily cooling load formed by walls was reduced by 44-55% under the intermittent operation and the interior insulation wall had the highest energy conservation rate of 52-65%, which was 7-19% higher than other wall insulation forms. If air-conditioning had operated for a long time, a short stop would not reduce the cooling load formed by walls. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 50 条
  • [1] Effect of the thermal insulation layer location on wall dynamic thermal response rate under the air-conditioning intermittent operation
    Zhang, Lili
    Luo, Tao
    Meng, Xi
    Wang, Yating
    Hou, Chaoping
    Long, Enshen
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 79 - 85
  • [2] Effect of the insulation materials filling on the thermal performance of sintered hollow bricks under the air-conditioning intermittent operation
    Hou, Chaoping
    Meng, Xi
    Gao, Yanna
    Mao, Wei
    Long, Enshen
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2018, 8 : 217 - 225
  • [3] Thermal performance optimization of building floors under air-conditioning intermittent operation by numerical simulation
    Meng, Xi
    Du, Junfei
    Wang, Yating
    Gao, Yanna
    [J]. JOURNAL OF BUILDING PHYSICS, 2019, 43 (02) : 99 - 120
  • [4] Thermal comfort in an office with intermittent air-conditioning operation
    Xu, X. G.
    Sit, K. Y.
    Deng, S. M.
    Chan, M. Y.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2010, 31 (01): : 91 - 100
  • [5] Thermal performance assessment of exterior building walls under intermittent air-conditioning operation in China's hot summer and cold winter zone
    Xu, Lu
    Ding, Yong
    Du, Chenqiu
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [6] Optimization of the thermal performance of self-insulation hollow blocks under conditions of cold climate and intermittent running of air-conditioning
    Hu, Wentao
    Huang, Yue
    Yuan, Meng
    Zhang, Jiaying
    Alekhin, V. N.
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2022, 35
  • [7] Location combination optimization of thermal insulation material and phase-change material in multi-layer walls under air-conditioning continuous and intermittent operation
    Geng, Xuechuan
    Wang, Jiahui
    Gao, Yanna
    Meng, Xi
    [J]. JOURNAL OF ENERGY STORAGE, 2021, 44
  • [8] Air-conditioning energy consumption due to green roofs with different building thermal insulation
    Jim, C. Y.
    [J]. APPLIED ENERGY, 2014, 128 : 49 - 59
  • [9] Analysis of Indoor Thermal Comfort of Different Air-conditioning Systems
    Zhao, Jianhui
    Xu, Hongyi
    Wu, Yehao
    Lei, Chao
    [J]. 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2021, 647
  • [10] High velocity seawater air-conditioning with thermal energy storage and its operation with intermittent renewable energies
    Hunt, Julian David
    Zakeri, Behnam
    Nascimento, Andreas
    Garnier, Bruno
    Pereira, Marcio Giannini
    Bellezoni, Rodrigo Augusto
    de Assis Brasil Weber, Natalia
    Schneider, Paulo Smith
    Machado, Pedro Paulo Bezerra
    Ramos, Dorel Soares
    [J]. ENERGY EFFICIENCY, 2020, 13 (08) : 1825 - 1840