Comparative analysis on thermal performance of different wall insulation forms under the air-conditioning intermittent operation in summer

被引:44
|
作者
Meng, Xi [1 ]
Luo, Tao [2 ]
Gao, Yanna [1 ]
Zhang, Lili [1 ]
Huang, Xing [1 ]
Hou, Chaoping [1 ]
Shen, Qiong [1 ]
Long, Enshen [3 ]
机构
[1] Sichuan Agr Univ, Coll Architectural & Urban Rural Planning, Dujiangyan, Sichuan, Peoples R China
[2] Minist Agr, Biogas Inst, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Sichuan, Peoples R China
关键词
Wall insulation structures; Intermittent operation; Continuous operation; Energy efficiency; OPTIMAL TEMPERATURE CONTROL; FLOW METER METHOD; PREDICTIVE CONTROL; STRUCTURAL WALLS; HEAT-TRANSFER; BUILDINGS; TIME; COEFFICIENT;
D O I
10.1016/j.applthermaleng.2017.11.042
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning intermittent operation is widely applied in building daily management, but more attention is focused on the air-conditioning continuous operation to simplify the energy-saving design. And the air-conditioning operation difference between the daily use and the energy-saving design must lead to large discrepancies in the energy efficiency and energy consumption between the actual usage and the primary design. Taking into account this situation, a verified numerical simulation was carried on to comparatively analyze the thermal performance of different wall insulation forms under air-conditioning intermittent and continuous operation in summer. The numerical results showed that the different wall insulation forms had a remarkable effect on the temperature response rate and the heat flow of the inner surface under the air-conditioning intermittent operation, although they had the same heat transfer coefficients. The interior insulation was more suitable for the wall insulation form under air-conditioning intermittent operation, while the heavyweight self-insulation and exterior insulation were more suitable under air-conditioning continuous operation. Compared with the air-conditioning continuous operation, the daily cooling load formed by walls was reduced by 44-55% under the intermittent operation and the interior insulation wall had the highest energy conservation rate of 52-65%, which was 7-19% higher than other wall insulation forms. If air-conditioning had operated for a long time, a short stop would not reduce the cooling load formed by walls. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 50 条
  • [41] Investigation on Thermal Performance of Earth-to-Air Heat Exchanger Under Different Operation Strategies
    Liu, Qing-Gong
    Du, Zhen-Yu
    [J]. Du, Zhen-Yu (dsdd2004@163.com), 1600, Science Press (41): : 420 - 429
  • [42] EER or Fcsp: A performance analysis of fixed and variable air conditioning at different cooling thermal conditions
    Andrade, Angel
    Restrepo, Alvaro
    Tibaquira, Juan E.
    [J]. ENERGY REPORTS, 2021, 7 : 537 - 545
  • [43] Development of control-oriented models for a building under regular heating, ventilation and air-conditioning operation-a comparative simulation study and an experimental validation
    Shamachurn, Heman
    Hassen, Sayed Z. Sayed
    [J]. INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2023, 42 (01) : 83 - 104
  • [44] Exergy analysis of hybrid air-conditioning systems with different evaporative-cooling condensers under hot-humid climates
    Yang, Yang
    Yang, Boyu
    Zeng, Jun
    Yin, Linmao
    Xie, Zhiyi
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [45] Analysis of thermal performance of a new regenerated glass pumice external wall insulation system in hot summer and cold winter zone
    Gu, Qian
    Ren, Sheng
    Wang, Yue
    Luo, Hao
    [J]. CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 1791 - 1795
  • [46] Analysis on behavior and evaluation on performance of solid desiccant air handling unit under various operation condition in summer
    Ukai, Makiko
    Tanaka, Hiroaki
    Tanaka, Hideki
    Okumiya, Masaya
    [J]. AIJ Journal of Technology and Design, 2015, 21 (49) : 1133 - 1138
  • [47] Comparative scuffing performance and chemical analysis of metallic surfaces for air-conditioning compressors in the presence of environmentally friendly CO2 refrigerant
    Nunez, Emerson Escobar
    Demas, Nicholaos G.
    Polychronopoulou, Kyriaki
    Polycarpou, Andreas A.
    [J]. WEAR, 2010, 268 (5-6) : 668 - 676
  • [48] Comparative Analysis on Dehumidification Performance of KCOOH-LiCl Hybrid Liquid Desiccant Air-Conditioning System: An Energy-Saving Approach
    Kumar, Kashish
    Singh, Alok
    Shaik, Saboor
    Saleel, C. Ahamed
    Aabid, Abdul
    Baig, Muneer
    [J]. SUSTAINABILITY, 2022, 14 (06)
  • [49] Dynamic heat-transfer mechanism and performance analysis of an integrated Trombe wall with radiant cooling for natural cooling energy harvesting and air-conditioning
    Zheng, Xinyao
    Zhou, Yuekuan
    [J]. ENERGY, 2024, 288
  • [50] Performance evaluation of a waste-heat driven adsorption system for automotive air-conditioning: Part II - Performance optimization under different real driving conditions
    Verde, M.
    Harby, K.
    de Boer, Robert
    Corberan, Jose M.
    [J]. ENERGY, 2016, 115 : 996 - 1009