Fractionation of whey proteins with high-capacity superparamagnetic ion-exchangers

被引:38
|
作者
Heeboll-Nielsen, A [1 ]
Justesen, SFL [1 ]
Thomas, ORT [1 ]
机构
[1] Tech Univ Denmark, Ctr Proc Biotechnol, BioCent DTU, DK-2800 Lyngby, Denmark
关键词
activation/functionalization chemistry; high-gradient magnetic fishing; lactoperoxidase; polyethylene imine; non-porous adsorbents; tentacular ligands;
D O I
10.1016/j.jbiotec.2004.06.008
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study we describe the design, preparation and testing of superparamagnetic anion-exchangers, and their use together with cation-exchangers in the fractionation of bovine whey proteins as a model study for high-gradient magnetic fishing. Adsorbents prepared by attachment of trimethyl amine to particles activated in sequential reactions with allyl bromide and N-bromosuccinimide yielded a maximum bovine serum albumin binding capacity of 156 mg g(-1) combined with a dissociation constant of 0.60 muM, whereas ion-exchangers created by linking polyethylene imine through superficial aldehydes bound up to 337 mg g(-1) with a dissociation constant of 0.042 muM. The latter anion-exchanger was selected for studies of whey protein fractionation. In these, crude bovine whey was treated with a superparamagnetic cation-exchanger to adsorb basic protein species, and the supernatant arising from this treatment was then contacted with the anion-exchanger. For both adsorbent classes of ion-exchanger, desorption selectivity was subsequently studied by sequentially increasing the concentration of NaCl in the elution buffer. In the initial cation-exchange step quantitative removal of lactoferrin (LF) and lactoperoxidase (LPO) was achieved with some simultaneous binding of immunoglobulins (1g). The immunoglobulins were separated from the other two proteins by desorbing with a low concentration of NaCl (less than or equal to0.4 M), whereas lactoferrin and lactoperoxidase were co-eluted in significantly purer form, e.g. lactoperoxidase was purified 28-fold over the starting material, when the NaCl concentration was increased to 0.4-1 M. The anion-exchanger adsorbed beta-lactoglobulin (beta-LG) selectively allowing separation from the remaining protein. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:247 / 262
页数:16
相关论文
共 50 条
  • [11] DETERMINATION OF ION-EXCHANGE CAPACITY OF SOLID ION-EXCHANGERS BY DIFFERENCE WEIGHING
    BUNZL, K
    SANSONI, B
    ANALYTICAL CHEMISTRY, 1976, 48 (14) : 2279 - 2281
  • [12] Fabrication of high-capacity protein ion-exchangers with polymeric ion-exchange groups grafted onto micron-sized beads by atom transfer radical polymerization
    Li, Shu
    Sun, Yan
    Shi, Qing-Hong
    BIOCHEMICAL ENGINEERING JOURNAL, 2015, 103 : 122 - 129
  • [13] CHROMATOGRAPHY OF URANIUM ON HIGH-PERFORMANCE ION-EXCHANGERS
    CASSIDY, RM
    ELCHUK, S
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1981, 10 (3-4) : 287 - 294
  • [14] COMPARISON OF NEW HIGH-CAPACITY ION-EXCHANGE SILICAS OF SPHEROSIL TYPE AND NORMAL MICROPARTICULATE ION-EXCHANGERS OF POLYSTYRENE DIVINYLBENZENE TYPE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CAUDE, M
    ROSSET, R
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (09) : 405 - 412
  • [15] GROUP FRACTIONATION OF PLASMA PROTEINS ON DIPOLAR ION EXCHANGERS
    PORATH, J
    FORNSTED.N
    JOURNAL OF CHROMATOGRAPHY, 1970, 51 (03): : 479 - &
  • [16] NEW ION-EXCHANGERS TRISACRYL - USE AND APPLICATION TO PLASMA-PROTEIN FRACTIONATION PROCESS
    SAINTBLANCARD, J
    FOURCART, J
    LIMONNE, F
    GIROT, P
    BOSCHETTI, E
    ANNALES PHARMACEUTIQUES FRANCAISES, 1981, 39 (05): : 403 - 409
  • [17] High-capacity anion exchangers based on poly (glycidylmethacrylate-divinylbenzene) microspheres for ion chromatography
    Liu, Junwei
    Wang, Yong
    Cheng, Heli
    Wang, Nani
    Wu, Shuchao
    Zhang, Peimin
    Zhu, Yan
    TALANTA, 2016, 159 : 272 - 279
  • [19] SWEETENING-OFF OF HIGH SOLIDS SOLUTIONS FROM ION-EXCHANGERS
    TENG, YE
    SAUER, CA
    REACTIVE POLYMERS, 1984, 2 (03): : 233 - 236
  • [20] High purity scandium and ion-exchangers: Application in neutron activation analysis
    Swain, KK
    Kayasth, S
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 260 (03) : 595 - 599