Consecutive contralateral comparison of toric and non-toric implantable collamer lenses V4c in vault after implantation for myopia and astigmatism

被引:12
|
作者
Zhao, Jiao [1 ]
Zhao, Jing [2 ,3 ,4 ,5 ]
Yang, Wen [6 ]
Li, Meiyan [2 ,3 ,4 ,5 ]
Hao, Gengsheng [1 ]
Chen, Zhuoyi [2 ,3 ,4 ,5 ]
Wang, Xiaoying [2 ,3 ,4 ,5 ]
Yao, Peijun [2 ,3 ,4 ,5 ]
Zhou, Xingtao [2 ,3 ,4 ,5 ]
机构
[1] Peoples Hosp Leshan, Dept Ophthalmol, Leshan, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Eye Inst, Shanghai, Peoples R China
[3] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, 83 Fenyang Rd, Shanghai 200031, Peoples R China
[4] Fudan Univ, Chinese Acad Med Sci, Key Lab Myopia, NHC Key Lab Myopia, Shanghai, Peoples R China
[5] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[6] Southwest Jiaotong Univ, Peoples Hosp Chengdu 3, Dept Ophthalmol, Affiliated Hosp, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
implantable collamer lens; myopia; pupil diameter; Vault; PHAKIC INTRAOCULAR-LENS; ACCOMMODATION; EYES;
D O I
10.1111/aos.14720
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To compare the vault performance between implantable collamer lens (ICL) V4c and Toric ICL (TICL) V4c after implantation and to investigate the affecting factors. Methods Sixty-eight eyes from 34 patients with myopia or myopia astigmatism who underwent implantation of TICL in one eye (group A) and identically sized ICL (group B) in the contralateral eye were included. Mean follow-up time were 7.58 +/- 1.63 months (range: 6-10 months). Vault was compared between the two groups and correlations between vault and age, preoperative ocular biometric measurements were analysed. Generalized estimating equation (GEE) model of postoperative vault adjusting for within-patient intereye correlations was performed. Results The safety indices were 1.27 and 1.35, and the efficacy indices were 1.20 and 1.24 for groups A and B, respectively. Vault of TICL was significantly higher than that of ICL (554.11 +/- 219.36 mu m vs 449.70 +/- 172.47 mu m, P < 0.001). The difference between ICL/TICL size and WTW (size-WTW) and STS (size-STS), anterior chamber depth and pupil diameter (PD) were positively correlated with vault. Patient age and clear lens rise measured by Pentacam were negatively correlated with vault. Results of GEE model showed preoperative PD, age, cylindrical power of TICL and size-WTW were influencing factors for postoperative vault. Conclusions Vault after TICL implantation is higher than that with ICL. PD, age, cylindrical power of TICL and size-WTW could affect postoperative vault.
引用
收藏
页码:E852 / E859
页数:8
相关论文
共 50 条
  • [21] Comparison of Astigmatism Prediction Error Taken with Galilei, Barrett Formula for Non-toric Intraocular Lens Implantation
    Ho, Yi-Ju
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [22] Rotational Stability and Visual Outcomes of V4c Toric Phakic Intraocular Lenses
    Lee, Hun
    Kang, David Sung Yong
    Choi, Jin Young
    Ha, Byoung Jin
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-im
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (07) : 489 - +
  • [23] Comparison of Refractive Stability After Non-toric Versus Toric Intraocular Lens Implantation During Cataract Surgery REPLY
    Jeon, Jei Hun
    Rim, Hyung Taek Tyler
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-Im
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) : 919 - 919
  • [24] Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens
    S Y Lee
    H J Kwon
    H S Ahn
    K Y Seo
    E K Kim
    T-I Kim
    Eye, 2011, 25 : 1409 - 1417
  • [25] Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens
    Lee, S. Y.
    Kwon, H. J.
    Ahn, H. S.
    Seo, K. Y.
    Kim, E. K.
    Kim, T-I
    EYE, 2011, 25 (11) : 1409 - 1417
  • [26] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [27] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Qinghong Lin
    Dong Yang
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [28] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Cao, Weifang
    Zhang, Suhua
    Liu, Qian
    Zhou, Jing
    Yuan, Xiaoyong
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4111 - 4120
  • [29] Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia A cohort study
    Tian, Ying
    Jiang, Hai-Bo
    Jiang, Jian
    Wen, Dan
    Xia, Xiao-Bo
    Song, Wei-Tao
    MEDICINE, 2017, 96 (25)
  • [30] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Weifang Cao
    Suhua Zhang
    Qian Liu
    Jing Zhou
    Xiaoyong Yuan
    International Ophthalmology, 2023, 43 : 4111 - 4120