Validity of D-dimer tests in the diagnosis of deep vein thrombosis: a prospective comparative study of three quantitative assays

被引:22
|
作者
Larsen, TB
Stoffersen, E
Christensen, CS
Laursen, B
机构
[1] Aalborg Hosp, Dept Clin Biochem, Sect Thrombosis & Hemostasis, Aalborg, Denmark
[2] Aalborg Hosp, Dept Radiol, Aalborg, Denmark
[3] Aalborg Hosp, Dept Haematol, Aalborg, Denmark
关键词
D-dimer; deep vein thrombosis; diagnosis; diagnostic accuracy; prospective study; sensitivity; specificity; ultrasonography;
D O I
10.1046/j.1365-2796.2002.00998.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To assess the diagnostic reliability of a new quantitative D-dimer assay (VIDAS New((R)) ) and an established quick test (Nycocard((R)) D-dimer assay) in the diagnosis of deep vein thrombosis (DVT) compared with ultrasonography. A third assay (Auto Dimer((R)) ) became available during sample collection and has been included in the final assessment. The diagnostic performance of the Auto Dimer((R)) assay was evaluated on three different coagulation analysers. Design. A clinical prospective study of patients admitted to hospital for evaluation of DVT. Setting. The admission ward at Aalborg Hospital. Subjects. A total of 113 outpatients with suspected DVT. Main outcome measures. Compression ultrasonography was used as the reference method for a diagnosis of DVT and compared with different D-dimer assays. The results were expressed as sensitivity, specificity, positive predictive value and negative predictive value (NPV). Results. Deep vein thrombosis was established in 49 patients (43%). Two D-dimer assays (VIDAS New((R)) and Auto Dimer((R)) ) showed sensitivities of 90 and 88%, specificities of 42 and 44%, and NPV's of 85 and 83%, respectively. The Nycocard((R)) D-dimer assay showed a sensitivity of 63%, specificity of 67% and NPV of 71%. Conclusions. The diagnostic performance of VIDAS New((R)) and the Auto Dimer((R)) D-dimer assays is almost identical, but this study suggests that neither of the D-dimer assays is suitable as the only screening method for DVT, in a situation with a high pretest probability of DVT. This call for a differential strategy that distinguishes between cases of low and high clinical probability using either a D-dimer test or ultrasonography.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 50 条
  • [41] Deep Vein Thrombosis, Tranexamic Acid, and a Negative D-Dimer
    Mihalache, Raluca M.
    Ames, Paul R. J.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2012, 18 (06) : 666 - 667
  • [42] D-Dimer as a risk factor for deep vein thrombosis: The Leiden Thrombophilia Study
    Andreescu, ACM
    Cushman, M
    Rosendaal, FR
    THROMBOSIS AND HAEMOSTASIS, 2002, 87 (01) : 47 - 51
  • [43] The diagnosis of deep vein thrombosis in symptomatic outpatients and the potential for clinical assessment and D-dimer assays to reduce the need for diagnostic imaging
    Keeling, DM
    Mackie, IJ
    Moody, A
    Watson, HG
    BRITISH JOURNAL OF HAEMATOLOGY, 2004, 124 (01) : 15 - 25
  • [44] The value of clinical findings and D-Dimer tests in diagnosing deep vein thrombosis in primary care
    Oudega, Ruud
    Hoes, Arno W.
    Toll, Diane B.
    Moons, Karel G. M.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2006, 32 (07): : 673 - 677
  • [45] D-dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep vein thrombosis: prospective cohort study
    Bernardi, E
    Prandoni, P
    Lensing, AWA
    Agnelli, G
    Guazzaloca, G
    Scannapieco, G
    Piovella, F
    Verlato, F
    Tomasi, C
    Moia, M
    Scarano, L
    Girolami, A
    BRITISH MEDICAL JOURNAL, 1998, 317 (7165): : 1037 - 1040
  • [46] Residual Vein Thrombosis and D-Dimer for Optimizing Duration of Anticoagulation in Idiopathic Deep Vein Thrombosis
    Malato, Alessandra
    Saccullo, Giorgia
    Iorio, Alfonso
    Ageno, Walter
    Siragusa, Sergio
    CURRENT PHARMACEUTICAL DESIGN, 2010, 16 (31) : 3483 - 3486
  • [47] The usefulness of five D-dimer assays in the exclusion of deep venous thrombosis
    Schutgens, REG
    Haas, FJLM
    Gerritsen, WBM
    Van der Horst, F
    Nieuwenhuis, HK
    Biesma, DH
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (05) : 976 - 981
  • [48] D-dimer assays for deep venous thrombosis: A systematic review.
    Heim, SW
    Philbrick, JT
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2002, 17 : 112 - 112
  • [49] Contribution of a new, rapid, quantitative and automated method for D-Dimer measurement (BC D-Dimer) to exclude deep vein thrombosis in symptomatic outpatients
    Legnani, C
    Pancani, C
    Palareti, G
    Guazzaloca, G
    Fortunato, G
    Grauso, F
    Coccheri, S
    THROMBOSIS RESEARCH, 1998, 91 (03) : S58 - S59
  • [50] Utility of D-dimer for diagnosis of deep vein thrombosis in coronavirus disease-19 infection
    Cho, Edward S.
    McClelland, Paul H.
    Cheng, Olivia
    Kim, Yuri
    Hu, James
    Zenilman, Michael E.
    D'Ayala, Marcus
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2021, 9 (01) : 47 - 53