A self-calibrating sun tracker based on a differential pressure control system

被引:0
|
作者
Lin, Wenqiang [1 ]
Deng, Guangrong [1 ]
Wang, Tingting [1 ]
Sun, Lin [1 ]
Du, Li [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang, Peoples R China
关键词
sun tracker; self-calibrating; differential pressure; self-locking;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The efficiency of converting sunlight to electricity via photovoltaic panels can be significantly improved by using sun tracking. Sun trackers are such devices for efficiency improvement. To solve the problem that the existing sun-tracking apparatus cannot work without electricity, this paper puts forward an automatic sun tracker driven by differential pressure controlled system. The system has two axes of motion, being respectively responsible for tracking the solar altitude angle and azimuth angle synchronously by exploiting one propellant gas with a low boiling point. The performance and working principle of the self-calibrating system will be introduced and tested. This paper also presents a self-locking device to assure the stability of the system and quantitatively researches the self-locking performance and unlocking conditions through an experiment. On the basis of experimental prototype, the feasibility of this type of sun tracker is verified.
引用
收藏
页码:450 / 453
页数:4
相关论文
共 50 条
  • [31] A self-calibrating bandpass filter and transceiver system tuning and test technique
    Frost, C
    Levy, G
    Allison, B
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 1317 - 1321
  • [32] Continuously Self-Calibrating CVG System Using Hemispherical Resonator Gyroscopes
    Trusov, Alexander A.
    Phillips, Mark R.
    McCammon, George H.
    Rozelle, David M.
    Meyer, A. Douglas
    2015 2ND IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS AND SYSTEMS (ISISS), 2015, : 18 - 21
  • [33] HMA-III: A SELF-CALIBRATING WIRELESS MICROPHONE ARRAY SYSTEM
    Silverman, Harvey
    Shakya, Rahul
    Silverman, Ken
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 3871 - 3874
  • [34] A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats
    Uemura, K
    Kawada, T
    Sugimachi, M
    Zheng, C
    Kashihara, K
    Sato, T
    Sunagawa, K
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (06): : H2906 - H2913
  • [35] Self-calibrating optic thermometer based on dual-emission nanocomposite
    Yu, Yunlong
    Guan, Xiangfeng
    Luo, Peihui
    Li, Xiaoyan
    Yan, Fengpo
    Zhang, Weilong
    JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 730 : 12 - 16
  • [36] Self-calibrating Sensitivity Based on Regularized Least Squares for Parallel Imaging
    Liu, Xiaofang
    Zhu, Yihong
    Chen, Yongli
    Xu, Wenlong
    COMPUTER SCIENCE FOR ENVIRONMENTAL ENGINEERING AND ECOINFORMATICS, PT 2, 2011, 159 : 383 - +
  • [37] Hall-effect based self-calibrating geartooth sensing technology
    Vig, Ravi
    Milano, Shaun
    Electronic Engineering (London), 2000, 72 (876):
  • [38] Self-calibrating optic thermometer based on dual-emission nanocomposite
    Yu, Yunlong (ylyu@fjjxu.edu.cn), 1600, Elsevier Ltd (730):
  • [39] A Temperature Self-calibrating Torsional Accelerometer with Fully Differential Configuration and Integrated Reference Capacitor
    Xiao, Dingbang
    Xia, Dewei
    Li, Qingsong
    Wu, Yulie
    Chen, Zhihua
    Wu, Xuezhong
    2015 IEEE SENSORS, 2015, : 991 - 994
  • [40] Self-calibrating differential predictive floating-point analog-to-digital converter
    Groza, V
    Debski, M
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 1604 - 1606