Aqua and Terra MODIS RSB Calibration Comparison Using BRDF Modeled Reflectance

被引:10
|
作者
Chang, Tiejun [1 ]
Xiong, Xiaoxiong [2 ]
Angal, Amit [1 ]
Wu, Aisheng [1 ]
Geng, Xu [1 ]
机构
[1] Sci Syst & Applicat Inc, Lanham, MD 20706 USA
[2] NASA, Goddard Space Flight Ctr, Sci & Explorat Directorate, Greenbelt, MD 20771 USA
来源
关键词
Atmospheric correction; bidirectional reflectance distribution function (BRDF); intercomparison; Moderate Resolution Imaging Spectroradiometer (MODIS); Radiometric calibration; RESOLUTION IMAGING SPECTRORADIOMETER; RADIATIVE-TRANSFER CODE; SOLAR BANDS; CROSS-CALIBRATION; ATMOSPHERIC CORRECTION; VECTOR VERSION; SATELLITE DATA; PERFORMANCE; RETRIEVAL; SENSORS;
D O I
10.1109/TGRS.2016.2641258
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The intercomparison of Moderate Resolution Imaging Spectroradiometer (MODIS) reflective solar bands onboard Aqua and Terra is very important for the assessment of each instrument's calibration. One of the limitations is the lack of simultaneous nadir overpasses. Their measurements over a selected Earth view target have significant differences in solar and view angles, which magnify the effects of atmospheric scattering and bidirectional reflectance distribution function (BRDF). In this paper, an intercomparison technique is formulated after correction for site's BRDF and atmospheric effects. The reflectance measurements over Libya desert sites 1, 2, and 4 from both the Aqua and Terra MODIS are regressed to a BRDF model with an adjustable coefficient accounting for calibration difference. The ratio between Aqua and Terra reflectance measurements is derived for bands 1-9 and the results from different sites show good agreement. For year 2003, the ratios are in the range of 0.985-1.010 for bands 1-9. Band 3 shows the lowest ratio 0.985 and band 1 shows the highest ratio 1.010. For the year 2014, the ratio ranges from approximately 0.983 for bands 2 and 1.012 for band 8. The BRDF corrected reflectance for the two instruments is also derived for every year from 2003 to 2014 for stability assessment. Bands 1 and 2 show greater than 1% differences between the two instruments. Aqua bands 1 and 2 show downward trends while Terra bands 1 and 2 show upward trends. Bands 8 and 9 of both Aqua and Terra show large variations of reflectance measurement over time.
引用
收藏
页码:2288 / 2298
页数:11
相关论文
共 50 条
  • [21] On-orbit Performance and Calibration Improvements for the Reflective Solar Bands of Terra and Aqua MODIS
    Angal, Amit
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chen, Hongda
    Geng, Xu
    Link, Daniel
    Li, Yonghong
    Wald, Andrew
    Brinkmann, Jake
    [J]. EARTH OBSERVING MISSIONS AND SENSORS: DEVELOPMENT, IMPLEMENTATION, AND CHARACTERIZATION IV, 2016, 9881
  • [22] On-orbit calibration and performance assessments of Terra and Aqua MODIS thermal emissive bands
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chang, Tiejun
    Wilson, Truman
    Li, Yonghong
    Chen, Na
    Shrestha, Ashish
    Diaz, Carlos Perez
    [J]. JOURNAL OF APPLIED REMOTE SENSING, 2021, 15 (01)
  • [23] Characterization of Terra and Aqua MODIS VIS, NIR, and SWIR Spectral Bands' Calibration Stability
    Wu, Aisheng
    Xiong, Xiaoxiong
    Doelling, David R.
    Morstad, Daniel
    Angal, Amit
    Bhatt, Rajendra
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (07): : 4330 - 4338
  • [24] Comparison of SeaWiFS, MODIS-Terra, MODIS-Aqua and MERIS satellites in the Southern Ocean
    Fantoni, R.
    Fiorani, L.
    Okladnikov, I. G.
    Palucci, A.
    [J]. OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2010, 4 (05): : 764 - 768
  • [25] Lunar calibration improvements for the short-wave infrared bands in Aqua and Terra MODIS
    Wilson, Truman
    Angal, Amit
    Shrestha, Ashish
    Xiong, Xiaoxiong
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXI, 2017, 10423
  • [26] Assessment of the Collection 6 Terra and Aqua MODIS Bands 1 and 2 Calibration Performance
    Wu, A.
    Chen, X.
    Angal, A.
    Li, Y.
    Xiong, X.
    [J]. EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [27] Intercomparison of On-Orbit Calibration Consistency Between Terra and Aqua MODIS Reflective Solar Bands Using the Moon
    Xiong, Xiaoxiong
    Sun, Junqiang
    Barnes, William
    [J]. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2008, 5 (04) : 778 - 782
  • [28] Calibration of the DSCOVR EPIC visible and NIR channels using MODIS Terra and Aqua data and EPIC lunar observations
    Geogdzhayev, Igor V.
    Marshak, Alexander
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (01) : 359 - 368
  • [29] Terra and Aqua MODIS Thermal Emissive Bands Calibration and RVS Stability Assessments Using an In Situ Ocean Target
    Diaz, Carlos L. Perez
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chang, Tiejun
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [30] Validation of the MODIS Bidirectional Reflectance Distribution Function and Albedo retrievals using combined observations from the Aqua and Terra platforms
    Salomon, Jonathan G.
    Schaaf, Crystal B.
    Strahler, Alan H.
    Gao, Feng
    Jin, Yufang
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2006, 44 (06): : 1555 - 1565