Dosimetric impact of tumor position displacements between photon and proton stereotactic body radiation therapy for lung cancer

被引:0
|
作者
Liu, Chieh-Wen [1 ]
Ma, Tianjun [2 ]
Gray, Tara [1 ]
Ahmed, Saeed [1 ]
Yu, Naichang [1 ]
Stephans, Kevin L. [1 ]
Videtic, Gregory M. M. [1 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, CA-50,9500 Euclid Ave, Cleveland, OH 44195 USA
[2] MedStar Georgetown Univ Hosp, Dept Radiat Med, 3800 Reservoir Rd NW, Washington, DC 20007 USA
来源
JOURNAL OF RADIOSURGERY AND SBRT | 2022年 / 8卷 / 02期
关键词
SBRT; proton; IMPT; anatomical change; tumor position displacement; adaptive radiotherapy; ADAPTIVE RADIOTHERAPY; RESPIRATORY MOTION;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To investigate the impact of tumor position displacements (TPDs) on tumor dose coverage in photon and proton stereotactic body radiation therapy (SBRT) treatments for lung cancer patients. Methods: From our institutional database of 2877 fractions from 770 lung cancer patients treated with photon SBRT in 2017-2021, 163 fractions from 88 patients with recorded iso-center shifts of >1.5 cm in any direction under kV-cone-beam CT guidance were identified. By double registrations with bony and tumor alignments, the difference between the iso-center shifts of these two alignments was categorized as TPDs. One fraction from each of 15 patients who had TPD magnitudes >3 mm were selected for this study. For each patient, one proton plan using intensity modulated proton therapy (IMPT) with robust optimization was generated retrospectively. All photon plans had V-100%RX>99% of GTVs and V-100%RX>98% of ITVs. Proton plans were evaluated with two worse-case scenario (voxelwise worst and worst scenario) using 5mm and 3.5% uncertainty to achieve the same planning goals as the corresponding photon plans. These two evaluation proton plans were named proton-1st and proton-2nd plans. The dosimetric effect of TPD was simulated by shifting tumor contours with the corresponding shift on patient specific planning CT and by recalculating the dose of the original plan. Results: The range of magnitude of TPDs was 3.58-28.71 mm. In photon plans, TPDs did not impact tumor dose coverage, still achieving V-100%RX of the GTV >= 99% and V-100%RX of the ITV >= 98%. In proton plans for patients with TPDs>10 mm, inadequate target dose coverage was observed. More specifically, 8 fractions of proton-1st plans and 4 fractions of proton-2nd had V-100% RX of the GTV<99% and V-100%RX of the ITV<98%. Conclusions: Adequate tumor dose coverage was achieved in photon SBRT for magnitude of TPDs up to 20 mm. TPDs had greater impact in proton SBRT and adaptive planning was needed when the magnitude of TPDs>10 mm to provide adequate tumor dose coverage.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 50 条
  • [31] Lung cancer: Stereotactic body radiation therapy and surgery
    Antoni, D.
    Srour, I.
    Mornex, F.
    CANCER RADIOTHERAPIE, 2015, 19 (6-7): : 371 - 376
  • [32] Advances in Stereotactic Body Radiation Therapy for Lung Cancer
    Lee, Katie N.
    Owen, Dawn
    CANCER JOURNAL, 2024, 30 (06): : 401 - 406
  • [33] STEREOTACTIC BODY RADIATION THERAPY FOR PATIENTS WITH LUNG CANCER
    Bianchi, L. C.
    Beltramo, G.
    Brait, L.
    Bergantin, A.
    Locatelli, F.
    Fariselli, L.
    Gerosa, C.
    Mariani, P.
    Tabiadon, D.
    Locatelli, M. C.
    ANNALS OF ONCOLOGY, 2009, 20
  • [34] Stereotactic Body Radiation Therapy for Inoperable Lung Cancer
    Rusthoven, Kyle E.
    Pugh, Thomas J.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 303 (23): : 2354 - 2355
  • [35] Stereotactic Body Radiation Therapy for Lung Cancer in Octogenarians
    Ishihara, T.
    Yamada, K.
    Tanahashi, M.
    Niwa, H.
    Matsui, T.
    Yokomura, K.
    Sasaki, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S550 - S551
  • [36] A Dosimetric Comparison of Stereotactic Body Radiation Therapy Delivery Techniques for Lung Cancer: Adaptive Versus Conventional
    Ding, C.
    Godley, A.
    Westover, K.
    Timmerman, R.
    Park, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [37] Passively Scattered Proton Stereotactic Body Radiation Therapy for Spine Metastasis: A Dosimetric Analysis
    MacEwan, I.
    Chou, B.
    Mifflin, R.
    Wroe, A.
    Bush, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E675 - E676
  • [38] Impact of Interstitial Changes on Radiation Pneumonitis After Stereotactic Body Radiation Therapy for Lung Cancer
    Yoshitake, Tadamasa
    Shioyama, Yoshiyuki
    Asai, Kaori
    Nakamura, Katsumasa
    Sasaki, Tomonari
    Ohga, Saiji
    Kamitani, Takeshi
    Yamaguchi, Toshihiro
    Ohshima, Kaori
    Matsumoto, Keiji
    Kawanami, Satoshi
    Honda, Hiroshi
    ANTICANCER RESEARCH, 2015, 35 (09) : 4909 - 4913
  • [39] Addressing the dosimetric impact of bone cement and vertebroplasty in stereotactic body radiation therapy
    Dumas, Jean-Luc
    Dal, Romaric
    Zefkili, Sofia
    Robilliard, Magalie
    Losa, Sandra
    Birba, Imene
    Vu-Bezin, Jeremi
    Beddok, Arnaud
    Calugaru, Valentin
    Dutertre, Guillaume
    De Marzi, Ludovic
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 42 - 49
  • [40] The Dosimetric Impact of Implants on the Spinal Cord Dose in Stereotactic Body Radiation Therapy
    Yazici, G.
    Yedekci, Y.
    Yucekul, A.
    Birgi, S.
    Demirkiran, G.
    Gultekin, M.
    Hurmuz, P.
    Yazici, M.
    Cengiz, M.
    Gurkaynak, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S909 - S909