A novel approach for the selection of human sperm using annexin V-binding and flow cytometry

被引:36
|
作者
Hoogendijk, Christiaan F. [1 ]
Kruger, Theunis F. [1 ]
Bouic, Patric J. D. [2 ]
Henkel, Ralf R. [3 ]
机构
[1] Tygerberg Acad Hosp, Reprod Biol Unit, ZA-7505 Tygerberg, South Africa
[2] Tygerberg Acad Hosp, Dept Med Microbiol, ZA-7505 Tygerberg, South Africa
[3] Univ Western Cape, Dept Med Biosci, ZA-7535 Bellville, South Africa
关键词
Sperm; human; morphology; apoptosis; separation technique; ZONA-PELLUCIDA BINDING; IN-VITRO FERTILIZATION; CYTOCHROME-C RELEASE; DNA FRAGMENTATION; HUMAN SPERMATOZOA; INVITRO FERTILIZATION; MALE-INFERTILITY; MEMBRANE PHOSPHATIDYLSERINE; CREATINE-KINASE; DEFORMITY INDEX;
D O I
10.1016/j.fertnstert.2008.01.042
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To develop a method whereby sperm with phosphatidylserine externalization can be separated from those without this feature. Because annexin V binds phosphatidylserine, this study is using this feature to select functional spermatozoa. In addition, the relationship between annexin V binding in human spermatozoa and normal sperm morphology according to strict criteria was to be assessed, Design: Prospective study. Setting: Department of Obstetrics and Gynaecology of Stellenbosch University at Tygerberg Academic Hospital, Tygerberg, South Africa. Patient(s): Semen from 14 healthy sperm donors. Exclusion criterion was the presence of less than 20 x 10(6)/mL total motile spermatozoa in the original sample. Main Outcome Measure(s): Annexin V-negative sperm, annexin V-positive sperm, normal sperm morphology. Intervention(s): An aliquot of a semen sample after double density gradient centrifugation was incubated with annexin V fluorescein isothiocyanate conjugate (FITC). Cell fluorescence signals were determined using a FACScalibur flow cytometer equipped with a FACSSort fluidic sorting module. The sorting procedure delivered two sperm subpopulations: annexin V-negative and annexin V-positive. Morphology slides were made and the sperm morphology was assessed according to strict criteria. Result(s): There was a significant enrichment of annexin V-negative sperm as well as morphologically normal sperm in the annexin V-negative subgroup after separation with flow cytometry. The percentage of morphologically normal sperm increased from 8.3% in the control to 11.9% in the annexin V-negative fraction, whereas the percentage of annexin V-positive sperm decreased to 5.7%. Conclusion(s): The annexin V-negative sperm subpopulation had morphologically superior quality sperm compared to annexin V-positive sperm. It is important to select morphologically normal sperm during intracytoplasmic sperm injection (ICSI) as it may contribute to increased implantation and pregnancy rates (PR). (Fertil Sterill (R) 2009;91:1285-92. (C) 2009 by American Society for Reproductive Medicine.)
引用
收藏
页码:1285 / 1292
页数:8
相关论文
共 50 条
  • [21] A novel method for measuring CTL and NK cell-mediated cytotoxicity using annexin V and two-color flow cytometry
    Goldberg, JE
    Sherwood, SW
    Clayberger, C
    JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 224 (1-2) : 1 - 9
  • [22] Sperm Sexing in Buffalo Using Flow Cytometry
    Lu, Kehuan
    Lu, Yangqing
    Zhang, M.
    Yang, Xiaogan
    BUFFALO BULLETIN, 2013, 32 : 22 - 30
  • [23] DNA flow cytometry of human spermatozoa:: Consistent stoichiometric staining of sperm DNA using a novel decondensation protocol
    Kovacs, Tamas
    Bekesi, Gyoengyi
    Fabian, Akos
    Rakosy, Zsuzsa
    Horvath, Gabor
    Matyus, Laszlo
    Balazs, Margit
    Jenei, Attila
    CYTOMETRY PART A, 2008, 73A (10) : 965 - 970
  • [24] Monomeric cyanine dye permeability correlates with annexin V staining on apoptotic cells using flow cytometry
    Buller, G
    Godfrey, W
    Probes, M
    FASEB JOURNAL, 2005, 19 (05): : A1673 - A1673
  • [25] Functional screening for modulators of mast cell exocytosis using a flow cytometry based annexin binding assay
    Demo, SD
    Masuda, E
    Rossi, AB
    Gerard, AL
    Chan, EH
    Armstrong, RJ
    Fox, BP
    Huang, BC
    Lorens, JB
    Luo, Y
    Shen, MR
    Payan, DG
    Schellar, RH
    Fisher, JM
    MOLECULAR BIOLOGY OF THE CELL, 1998, 9 : 203A - 203A
  • [26] Circulating monocyte-derived (CD14+) and apoptotic (annexin V-binding) microparticles correlate with recurrent atrial fibrillation
    Dzeshka, M. S.
    Shantsila, E.
    Snezhitskiy, V. A.
    Lip, G. Y. H.
    EUROPEAN HEART JOURNAL, 2018, 39 : 412 - 413
  • [27] Multicolor Flow Cytometry as a screening tool for human sperm
    Da Costa, R.
    Struenker, T.
    Redmann, K.
    Schlatt, S.
    HUMAN REPRODUCTION, 2019, 34 : 182 - 182
  • [28] Automation of human sperm cell analysis by flow cytometry
    Ferrara, F
    Daverio, R
    Mazzini, G
    Bonini, P
    Banfi, G
    CLINICAL CHEMISTRY, 1997, 43 (05) : 801 - 807
  • [29] Analysis of radiation-induced apoptosis in human lymphocytes: Flow cytometry using Annexin V and propidium iodide versus the neutral comet assay
    Wilkins, RC
    Kutzner, BC
    Truong, M
    Sanchez-Dardon, J
    McLean, JRN
    CYTOMETRY, 2002, 48 (01): : 14 - 19
  • [30] Release of annexin V-binding membrane microparticles from cultured human umbilical vein endothelial cells after treatment with camptothecin -: art. no. 11
    Simák, J
    Holada, K
    Vostal, JG
    BMC CELL BIOLOGY, 2002, 3 (1)