Adaptive lung ventilation (ALV) - Evaluation of a new closed-loop algorithm for surgery in the lateral decubitus position

被引:8
|
作者
Weiler, N
Eberle, B
Latorre, F
VonPaczynski, S
Heinrichs, W
机构
来源
ANAESTHESIST | 1996年 / 45卷 / 10期
关键词
adaptive lung ventilation; closed-loop control of ventilation; model of ventilation; pulmonary mechanics; artificial ventilation; work of breathing; nephrectomy; lateral decubitus position;
D O I
10.1007/s001010050329
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The lateral decubitus position is the standard position for nephrectomies. There is a lack of data about the effects of this extreme position upon respiratory mechanics and gas exchange. In 20 patients undergoing surgery in the nephrectomy position, we compared a new closed-loop-controlled ventilation algorithm, adaptive lung ventilation (ALV), which adapts the breathing pattern automatically, to the respiratory mechanics with conventionally controlled mandatory ventilation (CMV). The aims of our study were (1) to describe positioning effects on respiratory mechanics and gas exchange, (2) to compary ventilatory parameters selected by the ALV controller with traditional settings of CMV, and (3) to assess the individual adaptation of the ventilatory parameters by the ALV controller. The respirator used was a modified Amadeus ventilator, which is controlled by an external computer and possesses an integrated lung function analyzer. In a first set of measurements, we compared parameters of respiratory mechanics and gas exchange in the horizontal supine position and 20 min after changing to the nephrectomy position. In a second set of measurements, patients were ventilated with ALV and CMV using a randomized crossover design. The CMV settings were a tidal volume of 10 ml/kg body weight, a respiratory rate of 10 breaths/min, an I:E ratio of 1:1.5, and an end-inspiratory pause of 30% of inspiratory time. With both ventilation modes FiO2 was set to 0.5 and PEEP to 3 cm H2O. During ALV a desired alveolar ventilation of 70 ml/kg KG . min was preset. All other ventilatory parameters were determined by the ALV controller according to the instantaneously measured respiratory parameters. Positioning induced a reduction of compliance from 61.6 to 47.9 ml/cm H2O; the respiratory time constant shortened from 1.2 to 1.08 s, whereas physiological dead space increased from 158.9 to 207.5 ml. On average, the ventilatory parameters selected by the ALV controller resembled very closely those used with CMV. However, an adaptation to individual respiratory mechanics was clearly evident with ALV. In conclusion, we found that the effects of positioning for nephrectomy are minor and may give rise to problems only in patients with restrictive lung disease. The novel ALV controller automatically selects ventilatory parameters that are clinically sound and are better adapted to the respiratory mechanics of ventilated patients than the standardized settings of CMV are.
引用
收藏
页码:950 / 956
页数:7
相关论文
共 50 条
  • [21] Adaptive Lung Ventilation (ALV) during Anesthesia for Pulmonary Surgery: Automatic Response to Transitions to and from One-Lung Ventilation
    Norbert Weiler
    Balthasar Eberle
    Wolfgang Heinrichs
    Journal of Clinical Monitoring and Computing, 1998, 14 : 245 - 252
  • [22] Multi-channel adaptive control algorithm for closed-loop adaptive optics system
    Yan, Zhaojun
    Li, Xinyang
    Rao, Changhui
    Guangxue Xuebao/Acta Optica Sinica, 2013, 33 (03):
  • [23] Low dose inhaled nitric oxide and one lung ventilation in patients in lateral decubitus position.
    IsmailZade, I
    Vuylsteke, A
    Ghosh, S
    Latimer, RD
    ANESTHESIOLOGY, 1997, 87 (03) : A102 - A102
  • [24] Modified Lung Ultrasonographic Technique for Evaluation of Idiopathic Pulmonary Fibrosis: Lateral Decubitus Position
    Vassalou, Evangelia E.
    Raissaki, Maria
    Magkanas, Eleftherios
    Antoniou, Katerina M.
    Karantanas, Apostolos H.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (12) : 2525 - 2532
  • [25] A STUDY OF A REAL-TIME ADAPTIVE CLOSED-LOOP RESERVOIR CONTROL ALGORITHM
    BUCHANAN, RB
    BRAS, RL
    HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 1982, 27 (02): : 205 - 205
  • [26] A New Versatile Hardware Platform for Closed-Loop Gyro Evaluation
    Omar, A.
    Elshennawy, A.
    Ismail, A.
    Nagib, M.
    Elmala, M.
    Elsayed, A.
    2015 DGON INERTIAL SENSORS AND SYSTEMS SYMPOSIUM (ISS), 2015,
  • [27] Adaptive force/position control algorithm with closed loop of velocity for the haptic device
    Kong, Min-Xiu
    You, Wei
    Du, Zhi-Jiang
    Sun, Li-Ning
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (03): : 409 - 413
  • [28] Artificial intelligence for closed-loop ventilation therapy with hemodynamic control using the open lung concept
    Pomprapa, Anake
    Muanghong, Danita
    Koeny, Marcus
    Leonhardt, Steffen
    Pickerodt, Philipp
    Tjarks, Onno
    Schwaiberger, David
    Lachmann, Burkhard
    INTERNATIONAL JOURNAL OF INTELLIGENT COMPUTING AND CYBERNETICS, 2015, 8 (01) : 50 - 68
  • [29] Fully automated closed-loop ventilation is safe and effective in post-cardiac surgery patients
    Beijers, Ashley J. R.
    Roos, Arnout N.
    Bindels, Alexander J. G. H.
    INTENSIVE CARE MEDICINE, 2014, 40 (05) : 752 - 753
  • [30] THE AVL-MODE - A SAFE CLOSED-LOOP ALGORITHM FOR VENTILATION DURING TOTAL INTRAVENOUS ANESTHESIA
    WEILER, N
    HEINRICHS, W
    KESSLER, W
    INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1994, 11 (02): : 85 - 88