Percutaneous axillary artery access for fenestrated and branched thoracoabdominal endovascular repair

被引:36
|
作者
Bertoglio, Luca [1 ]
Mascia, Daniele [1 ]
Cambiaghi, Tommaso [1 ]
Kahlberg, Andrea [1 ]
Melissano, Germano [1 ]
Chiesa, Roberto [1 ]
机构
[1] Univ Vita Salute San Raffaele, Sci Inst H San Raffaele, Div Vasc Surg, Milan, Italy
关键词
AORTIC-VALVE IMPLANTATION; ANEURYSM REPAIR; REPORTING STANDARDS; EDITORS CHOICE; EXPERIENCE;
D O I
10.1016/j.jvs.2017.09.053
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of this study was to assess the safety and effectiveness of upper extremity access (UEA) with percutaneous closure of the axillary artery (AxA) during endovascular treatment of thoracoabdominal aortic aneurysms with fenestrated and branched endografts. Methods: Between January 2014 and 2017, 34 out of 37 patients (92%) required UEA during a staged branched and fenestrated endovascular approach. A percutaneous AxA (pAxA) approach was used in 14 consecutive patients (41%) with the off-label use of two Perclose ProGlide (Abbott Vascular, Santa Clara, Calif) devices. The results of patients who had received a pAxA access were analyzed; technical success was defined as successful arterial closure with no evidence of persistent bleeding or arterial occlusion requiring secondary interventions. Early (30 days) and short-term (6 months) success rates were recorded. The anatomic characteristics of the AxA of the entire cohort (34 cases) were studied. Results: Primary technical success of pAxA was 100%; in one case, an adjunctive Perclose ProGlide device was used to achieve complete closure. No secondary open or endovascular procedures were required. At predischarge computed tomography, no intimal defects, pseudoaneurysms, or signs of bleeding were observed, and all patients were discharged without neurologic deficits related to the AxA puncture site. All 14 patients are alive at follow-up, and 9 of 14 patients completed a 6-month clinical follow-up with computed tomography examination; no late complications were observed at the site of UEA percutaneous repair. With regard to the anatomic characteristics of the AxA, the vessel diameters in the first and third segments were statistically different (P <.001) with a median difference of 1.5 mm (1.0-2.0 mm), with no differences between the right and left sides. The distance between the end of the first segment of the AxA and the origin from the aortic arch was statistically different between the right and left sides, with a median difference of 36 mm (17-50 mm). A positive linear correlation was found between the diameter of the AxA and the height of the patients. Conclusions: AxA is adequate in terms of both caliber and lack of calcifications as an access vessel for large-sheath catheterizations, and it might be considered an alternative UEA for complex aortic endovascular procedures thanks to its proximity to visceral target vessels. In this preliminary experience, percutaneous closure of AxA access with the Perclose ProGlide device is clinically safe and technically feasible with high rates of success (J Vasc Surg 2018;68:12-23.)
引用
收藏
页码:12 / 23
页数:12
相关论文
共 50 条
  • [31] Endovascular Repair of Thoracoabdominal Aortic Aneurysm in High-Surgical Risk Patients: Fenestrated and Branched Endografts
    Gallitto, Enrico
    Gargiulo, Mauro
    Freyrie, Antonio
    Massoni, Claudio B.
    Pini, Rodolfo
    Mascoli, Chiara
    Faggioli, Gianluca
    Ancetti, Stefano
    Stella, Andrea
    ANNALS OF VASCULAR SURGERY, 2017, 40 : 170 - 177
  • [32] Geometric changes over time in bridging stents after branched and fenestrated endovascular repair for thoracoabdominal aneurysm
    de Niet, Arne
    Post, Richard B.
    Reijnen, Michel M. P. J.
    Zeebregts, Clark J.
    Tielliu, Ignace F. J.
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (03) : 702 - 709
  • [33] Aortic aneurysm, thoracoabdominal aneurysm, juxtarenal aneurysm, fenestrated endografts, branched endografts, and endovascular aneurysm repair
    Greenberg, Roy K.
    ABDOMINAL AORTIC ANEURYSM: GENETICS, PATHOPHYSIOLOGY AND MOLECULAR BIOLOGY, 2006, 1085 : 187 - 196
  • [34] Predictors of Failure to Rescue After Fenestrated-Branched Endovascular Aortic Repair of Thoracoabdominal Aortic Aneurysms
    Vacirca, Andrea
    Mesnard, Thomas
    Huang, Ying
    Mendes, Bernardo C.
    Jakimowicz, Tomasz
    Schneider, Darren B.
    Haulon, Stephan
    Sobocinski, Jonathan
    Beck, Adam W.
    Schanzer, Andres
    Farber, Mark A.
    Timaran, Carlos
    Kahlberg, Andrea
    Koelbel, Tilo
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2024, 79 (04) : 78S - 78S
  • [35] Spinal Cord Ischemia After Endovascular Repair of Thoracoabdominal Aortic Aneurysms With Fenestrated and Branched Stent Grafts
    Verhoeven, Eric L.
    Katsargyris, Athanasios
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 45S - 46S
  • [36] Retrograde aortic dissection following fenestrated and branched endovascular aortic repair for an extent III thoracoabdominal aneurysm
    Reinfeld, Susanne T.
    Blakeslee-Carter, Juliet
    Beck, Adam W.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2023, 9 (04):
  • [37] Comparison of Staging Strategies During Fenestrated-Branched Endovascular Aortic Repair of Thoracoabdominal Aortic Aneurysms
    Dias-Neto, Marina
    Jakimowicz, Tomasz
    Kolbel, Tilo
    Bertoglio, Luca
    Mees, Barend M.
    Schanzer, Andres
    Gasper, Warren J.
    Beck, Adam W.
    Farber, Mark A.
    Timaran, Carlos
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (06) : E238 - E239
  • [38] Fenestrated and Branched Endovascular Treatment of Recurrent Visceral Aortic Patch Aneurysm after Open Thoracoabdominal Repair
    Bertoglio, Luca
    Mascia, Daniele
    Cambiaghi, Tommaso
    Kahlberg, Andrea
    Melissano, Germano
    Chiesa, Roberto
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (01) : 72 - 77
  • [39] Effect of thoracoabdominal aortic aneurysm extent on outcomes in patients undergoing fenestrated/branched endovascular aneurysm repair
    Diamond, Kyle R.
    Simons, Jessica P.
    Crawford, Allison S.
    Arous, Edward J.
    Judelson, Dejah R.
    Aiello, Francesco
    Jones, Douglas W.
    Messina, Louis
    Schanzer, Andres
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (03) : 833 - +
  • [40] Target Artery Outcomes After Branched and Fenestrated Endovascular Repair of Pararenal and Thoracoabdominal Aortic Aneurysms in the US Investigational Device Exemption Experience
    Schneider, Darren B.
    Oderich, Gustavo S.
    Farber, Mark A.
    Schanzer, Andres
    Becks, Adam W.
    Timaran, Carlos H.
    Sweet, Matthew P.
    Tenorio, Emanuel R.
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (06) : E83 - E83