In-Situ saxs/waxd analysis on structural evolution in peek irradiated by 1 MeV electrons during tensile deformation

被引:3
|
作者
Li, Hongxia [1 ]
Yang, Jianqun [1 ]
Lv, Gang [1 ]
Dong, Saisai [1 ]
Tian, Feng [2 ]
Dong, Shangli [1 ]
Li, Xingji [1 ]
机构
[1] Harbin Inst Technol, Sch Mat Sci & Engn, Harbin 150001, Peoples R China
[2] Chinese Acad Sci, Shanghai Adv Res Inst, Zhangjiang Lab, Shanghai Synchrotron Radiat Facil, Shanghai 201204, Peoples R China
基金
中国国家自然科学基金;
关键词
Peek; Electron irradiation; Mechanical property; Saxs; WAXD; MECHANICAL-PROPERTIES; POLYETHERETHERKETONE PEEK; POLYETHYLENE; STRAIN; SAXS; FILM;
D O I
10.1016/j.polymdegradstab.2020.109350
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Polyether ether ketone (PEEK) is widely used as an electrical insulation material in aerospace field due to its excellent thermal and electrical properties. The changes in micro structure of the PEEK irradiated by 1 MeV electrons are studied by in-situ analysis of synchronous small-angle X-ray scattering (SAXS) and wide-angle X-ray diffraction (WAXD) during tensile deformation at room temperature. The tensile strength and the elongation at break of the irradiated PEEK decrease obviously, which is compared with the pristine one. The differential scanning calorimetry (DSC) analysis shows that the pristine PEEK begins to melt at 334.8 degrees C, the melting peak T-n, appears at 339.7 degrees C and a deeper exothermic crystallization peak T-n appears at 297.8 degrees C during the cooling process. The crystallization peak temperature decreases with the increase of the irradiation fluences. The pristine PEEK has a significant scattering peak along the meridian direction of the SAXS pattern, which indicates that the crystal lamellae of the material exhibits a certain orientation, and the position of the scattering peak changes little after irradiation. The intensity of SAXS decreases with the increasing of stretching strains, and the descent rate increases with the increasing of the irradiation fluences. According to the WAXD analysis, the width at half height of the diffraction peak increases with the increasing of the stretching strain, and the peak tends to disappear during tensile deformation. The diffraction peak disappearance rate increases with the increasing of the irradiation fluences. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 31 条
  • [1] In Situ WAXD and SAXS during Tensile Deformation Of Moulded and Sintered Polyamide 12
    Paolucci, Fabio
    Govaert, Leon
    Peters, Gerrit
    POLYMERS, 2019, 11 (06)
  • [2] Structural and morphological studies of isotactic polypropylene fibers during heat/draw deformation by in-situ synchrotron SAXS/WAXD
    Ran, SF
    Zong, XH
    Fang, DF
    Hsiao, BS
    Chu, B
    Phillips, RA
    MACROMOLECULES, 2001, 34 (08) : 2569 - 2578
  • [3] Crystal structural evolution and cavitation in biodegradable polyglycolide: An in-situ WAXD/SAXS study during hot-stretching
    Guo, Jin
    Fang, Chenxia
    Zhong, Yeshun
    Shan, Yiru
    Miao, Weijun
    Wang, Zongbao
    POLYMER, 2024, 311
  • [4] Structural evolution of stretch deformed HDPE/RGO nanocomposites: An in-situ synchrotron SAXS and WAXD study
    Li, Yiguo
    Duan, Tianchen
    Yao, Guibin
    Tang, Yujing
    Miao, Weijun
    Wang, Zongbao
    COMPOSITES SCIENCE AND TECHNOLOGY, 2019, 183
  • [5] In-situ synchrotron WAXD/SAXS studies of structural development during PBO/PPA solution spinning
    Ran, SF
    Burger, C
    Fang, DF
    Zong, XH
    Cruz, S
    Chu, B
    Hsiao, BS
    Bubeck, RA
    Yabuki, K
    Teramoto, Y
    Martin, DC
    Johnson, MA
    Cunniff, PM
    MACROMOLECULES, 2002, 35 (02) : 433 - 439
  • [6] Investigation of structural development of polyacrylonitrile fiber during thermal treatment by in-situ synchrotron WAXD/SAXS simultaneous measurements
    Hirano K.
    Sumiya K.
    Journal of Fiber Science and Technology, 2019, 75 (02): : 98 - 102
  • [7] Investigation of Structural Development of Polyacrylonitrile Fiber during Thermal Treatment by in-situ Synchrotron WAXD/SAXS Simultaneous Measurements
    Hirano, Kenji
    Sumiya, Kazunori
    SEN-I GAKKAISHI, 2019, 75 (02) : 98 - 102
  • [8] Structural evolution of β - iPP during uniaxial stretching studied by in-situ WAXS and SAXS
    Zhang, Chunbo
    Liu, Guoming
    Song, Yan
    Zhao, Ying
    Wang, Dujin
    POLYMER, 2014, 55 (26) : 6915 - 6923
  • [9] The segmental responses to orientation and relaxation of thermoplastic poly(ether-ester) elastomer during cyclic deformation: An in-situ WAXD/SAXS study
    Zhu, Ping
    Zhou, Chenxu
    Dong, Xia
    Sauer, Bryan B.
    Lai, Yue
    Wang, Dujin
    POLYMER, 2020, 188
  • [10] Structure Evolution During Uniaxial Tensile Deformation of High Density Polyethylene Before and After Irradiation by 1 MeV Electrons
    Rui, Erming
    Yang, Jianqun
    Li, Xingji
    Liu, Chaoming
    Tian, Feng
    Gao, Feng
    Li, Xiuhong
    Geng, Hongbin
    JOURNAL OF APPLIED POLYMER SCIENCE, 2014, 131 (10)