Novel aspiration catheter design for acute stroke thrombectomy

被引:33
|
作者
Long, Troy D. [1 ]
Kallmes, David F. [2 ]
Hanel, Ricardo [3 ]
Shigematsu, Tomoyoshi [4 ]
Halaszyn, Alexander Michael [5 ]
Wolter, Julia [5 ]
Berenstein, Alejandro [4 ]
机构
[1] North Mem Med Ctr, Robbinsdale, MN 55422 USA
[2] Mayo Clin, Rochester, MN USA
[3] Baptist Hlth, Jacksonville, FL USA
[4] Mt Sinai Hlth Syst, New York, NY USA
[5] Univ Minnesota, Minneapolis, MN USA
关键词
ACUTE ISCHEMIC-STROKE; 1ST PASS TECHNIQUE; ENDOVASCULAR TREATMENT; STENT-RETRIEVER; ADAPT TECHNIQUE; EXPERIENCE;
D O I
10.1136/neurintsurg-2017-013702
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background N avigable, large diameter aspiration catheters demonstrate markedly improved recanalization rates over smaller lumen devices in suction embolectomy. We evaluated the performance of a novel aspiration catheter system designed to maximize lumen size, and compare it to other commercially available aspiration catheters. Methods The 6F R4Q aspiration catheter system comprises a proximal pusher wire of 117 cm length connected to a distal catheter of 25 cm length. When placed through standard guide catheters and into the cerebral circulation, the proximal catheter makes a tight seal between its outer surface and the guide catheter's inner surface. During aspiration, in vitro flow rates and tip suction force under gentle retraction were compared among 10 commercially available aspiration catheters and the R4Q system. Results The R4Q 6F, 5F, 4F, and 3F catheters achieved flow rates at least 21.9%, 24.7%, 61.9%, and 244.7% greater than the other catheters tested respectively and the R4Q 6F produced a 140.2% higher tip force than a catheter of similar size. Fluid flow rate in the R4Q 6F increased on retraction into the guide catheter, delivering a 58.2% increase from fully extended to fully retracted. Conclusion The R4Q design demonstrates a substantial increase in aspirated flow rate and suction force due to an increased effective diameter than standard tubular catheter designs tested. The prominent increase in the aspiration parameters measured in vitro supports the potential for improved clinical results during stroke thrombectomy procedures.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 50 条
  • [41] Impact of aspiration catheter size on clinical outcomes in aspiration thrombectomy
    Schartz, Derrek
    Ellens, Nathaniel
    Kohli, Gurkirat Singh
    Rahmani, Redi
    Akkipeddi, Sajal Medha K.
    Colby, Geoffrey P.
    Hui, Ferdinand
    Bhalla, Tarun
    Mattingly, Thomas
    Bender, Matthew T.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023, 15 (E1) : E111 - E116
  • [42] A novel methodology for the modeling of catheter aspiration in high-fidelity thrombectomy simulations
    Bridio, Sara
    Luraghi, Giulia
    Dwivedi, Anushree
    McCarthy, Ray
    Matas, Jose Felix Rodriguez
    Migliavacca, Francesco
    2ND INTERNATIONAL CONFERENCE ON MEDICAL DEVICES:MATERIALS, MECHANICS AND MANUFACTURING, ICMD3M 2023, 2023, 49 : 67 - 73
  • [43] Mechanical thrombectomy with a novel beveled tip aspiration catheter: A technical case report
    Senturk, Cagin
    BRAIN CIRCULATION, 2022, 8 (04) : 215 - 218
  • [44] Catheter-Directed Thrombectomy for Pulmonary Embolism in the Setting of Acute Stroke
    Hoster, Clay H.
    Herring, Michael J.
    Planek, Maria Isabel C.
    Attanasio, Steve
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (08)
  • [45] Vac-lock augmented direct aspiration thrombectomy - A novel method of an aspiration first-pass approach for acute ischaemic stroke
    Teo, Kevin Soon Hwee
    Li, Jiahui
    Ribo, Marc
    Andersson, Tommy
    Yeo, Leonard
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2023, 455
  • [46] Emergent right coronary artery thrombectomy with a jet aspiration thrombectomy catheter
    Teiyu Yamauchi
    Shigeru Furui
    Takaaki Isshiki
    Hideki Toyoizumi
    Hiroshi Kohtake
    Kohji Takeshita
    Shigeru Suzuki
    Arimi Harasawa
    Yasushi Sasaki
    CardioVascular and Interventional Radiology, 1999, 22 : 340 - 342
  • [47] Emergent right coronary artery thrombectomy with a jet aspiration thrombectomy catheter
    Yamauchi, T
    Furui, S
    Isshiki, T
    Toyoizumi, H
    Kohtake, H
    Takeshita, K
    Suzuki, S
    Harasawa, A
    Sasaki, Y
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 22 (04) : 340 - 342
  • [48] Defining the optimal size of an aspiration catheter in relation to the arterial diameter during mechanical thrombectomy for stroke
    Charbonnier, Guillaume
    Primikiris, Panagiotis
    Desmarets, Maxime
    Tio, Gregory
    Vancheri, Sergio
    Di Caterino, Fortunato
    Vitale, Giovanni
    Biondi, Alessandra
    JOURNAL OF NEURORADIOLOGY, 2024, 51 (01) : 47 - 51
  • [49] Feasibility and safety of thrombectomy with TVAC aspiration catheter system for patients with acute myocardial infarction
    Jin Yokoyama
    Motoi Kushibiki
    Takayuki Fujiwara
    Yujin Tamura
    Naotaka Maeda
    Takumi Higuma
    Shingo Sasaki
    Fuminobu Yoshimachi
    Toshiro Matsunaga
    Hiroyuki Hanada
    Tomohiro Osanai
    Ken Okumura
    Heart and Vessels, 2006, 21 : 1 - 7
  • [50] A Novel Prehospital Scale to Predict Candidates for Acute Stroke Thrombectomy : The Fukuoka Acute Stroke ThrombEctomy pRediction (FASTER) Scale
    Miyazaki, Yuichi
    Tsumoto, Tomoyuki
    Matsuo, Ryu
    Ago, Tetsuro
    Kamouchi, Masahiro
    Yasaka, Masahiro
    Okada, Yasushi
    Kitazono, Takanari
    STROKE, 2017, 48