Optimal sizing of a wind/solar/battery/diesel hybrid microgrid based on typical scenarios considering meteorological variability

被引:34
|
作者
Yang, Dongfeng [1 ]
Jiang, Chao [1 ]
Cai, Guowei [1 ]
Huang, Nantian [1 ]
机构
[1] Northeast Elect Power Univ, Sch Elect Engn, Jilin 132012, Jilin, Peoples R China
关键词
diesel-electric power stations; optimisation; photovoltaic power systems; hybrid power systems; diesel-electric generators; distributed power generation; wind turbines; renewable energy sources; battery storage plants; time series; efficient operation; reliable operation; electric power system; stochastic nature; intermittent renewable energy; wind speed; load time series; stochastic characteristic; microgrid system planning; wind-irradiation-load typical scenarios generation method; optimal sizing; teaching-learning-based optimisation method; approximate the original scenarios; wind; solar; battery; diesel hybrid microgrid; meteorological variability; wind turbine; diesel generator; adequate energy; increased demands; conventional sources; associated energy storage system; economic operation; ESS; TLBO method; RENEWABLE ENERGY-SYSTEMS; CONTROL STRATEGIES; OPTIMIZATION; WIND; GENERATION; DESIGN; MANAGEMENT; STORAGE; COST;
D O I
10.1049/iet-rpg.2018.5944
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microgrid systems, such as solar photovoltaic (PV) and wind turbine (WT), integrated with diesel generator can provide adequate energy to supply increased demands and are economically feasible for current and future use considering depletion of conventional sources. It is, thus, important to determine the appropriate sizes of PV, WT, diesel generator, and associated energy storage system (ESS) for efficient, economic, and reliable operation of electric power system in microgrid. Stochastic nature of intermittent renewable energy (RE) resources complicate their planning, integration, and operation of electric power system. Therefore, it is critical to generate typical scenarios of wind speed, irradiation, and load time series to reflect their stochastic characteristic for microgrid system planning and operation. In this study, a wind-irradiation-load typical scenarios generation method is proposed for optimal sizing RE resources of microgrid. The teaching-learning-based optimisation (TLBO) method is used to find the best configuration of the microgrid system. Simulation results show that scenarios generated by the proposed model have ability to approximate the original scenarios and reduce planning data effectively.
引用
下载
收藏
页码:1446 / 1455
页数:10
相关论文
共 50 条
  • [31] A Novel Numerical Algorithm for Optimal Sizing of a Photovoltaic/Wind/Diesel Generator/Battery Microgrid Using Loss of Load Probability Index
    Kazem, Hussein A.
    Khatib, Tamer
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2013, 2013
  • [32] Optimal sizing of photovoltaic/battery/diesel based hybrid system and optimal tilting of solar array using the artificial intelligence for remote houses in India
    Jeyaprabha, S. Berclin
    Selvakumar, A. Immanuel
    ENERGY AND BUILDINGS, 2015, 96 : 40 - 52
  • [33] One optimal sizing method for designing hybrid solar-wind-diesel power generation systems
    Wei, Zhou
    Hongxing, Yang
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 1489 - 1494
  • [34] Optimal Sizing of Battery Energy Storage Systems Considering Cooperative Operation with Microgrid Components
    Takano, Hirotaka
    Hayashi, Ryosuke
    Asano, Hiroshi
    Goda, Tadahiro
    ENERGIES, 2021, 14 (21)
  • [35] Design and optimal sizing of hybrid PV/wind/diesel system with battery storage by using DIRECT search algorithm
    Zhang, Lu
    Barakat, Georges
    Yassine, Adnan
    2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [36] Optimal sizing of battery energy storage in a microgrid considering capacity degradation and replacement year
    Amini, Mohammad
    Khorsandi, Amir
    Vahidi, Behrooz
    Hosseinian, Seyed Hossein
    Malakmahmoudi, Ali
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195
  • [37] Study of the Influence of load profile variation on the optimal sizing of a standalone hybrid PV/Wind/Battery/Diesel system
    Bilal, B. Ould
    Sambou, V.
    Ndiaye, P. A.
    Kebe, C. M. F.
    Ndongo, M.
    TERRAGREEN 13 INTERNATIONAL CONFERENCE 2013 - ADVANCEMENTS IN RENEWABLE ENERGY AND CLEAN ENVIRONMENT, 2013, 36 : 1265 - 1275
  • [38] Energy Management System for Small Scale Hybrid Wind Solar Battery Based Microgrid
    Kumar, P. Satish
    Chandrasena, R. P. S.
    Ramu, V.
    Srinivas, G. N.
    Babu, K. Victor Sam Moses
    IEEE ACCESS, 2020, 8 : 8336 - 8345
  • [39] Optimal Operation Method for Microgrid with Wind/PV/Diesel Generator/Battery and Desalination
    Tang, Qingfeng
    Liu, Nian
    Zhang, Jianhua
    JOURNAL OF APPLIED MATHEMATICS, 2014,
  • [40] Optimal Sizing of a PV/Wind/Diesel Hybrid Energy System for Malaysia
    Mohamed, Azah
    Khatib, Tamer
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2013, : 752 - 757