Central corneal thickness in glaucoma

被引:45
|
作者
Sng, Chelvin C. A. [1 ,2 ,3 ]
Ang, Marcus [3 ,4 ,5 ]
Barton, Keith [1 ,2 ,5 ,6 ]
机构
[1] Moorfields Eye Hosp, Glaucoma Serv, 162 City Rd, London EC1V 2PD, England
[2] Natl Univ Hlth Syst, Dept Ophthalmol, Singapore, Singapore
[3] Singapore Eye Res Inst, Singapore, Singapore
[4] Singapore Natl Eye Ctr, Singapore, Singapore
[5] Moorfields Eye Hosp, Biomed Res Ctr Ophthalmol, Natl Inst Hlth Res, London, England
[6] UCL, Inst Ophthalmol, Dept Epidemiol & Genet, London, England
关键词
central corneal thickness; glaucoma; glaucoma management; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION TREATMENT; INTRAOCULAR-PRESSURE MEASUREMENTS; NORMAL-TENSION GLAUCOMA; GOLDMANN APPLANATION TONOMETRY; BIOMECHANICAL PROPERTIES; ULTRASOUND PACHYMETRY; AFRICAN-AMERICANS; REBOUND TONOMETER; HEALTHY-SUBJECTS;
D O I
10.1097/ICU.0000000000000335
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of reviewThe purpose of this review is to summarize the role of central corneal thickness (CCT) in the clinical management of a glaucoma patient.Recent findingsThe prognostic value of CCT is well recognized in patients with ocular hypertension. However, its predictive value in other glaucoma suspects and patients with established glaucoma is less certain. Tonometry artefacts can result from variations in CCT. However, an adequately validated correction algorithm for Goldmann applanation tonometry measurements does not exist. Newer methods of tonometry are potentially less influenced by CCT but are limited in their clinical use. There may also be biological and genetic associations between corneal thickness and glaucoma. Demographics, environmental factors, glaucoma treatment and the measurement device used have a significant influence on CCT, and should be considered when interpreting the effect of cornea thickness in patients with glaucoma. New measurements of the biomechanical properties of the cornea are likely to be better approximations of the globe biomechanics than CCT, but these require further evaluation.SummaryThe clinical significance of CCT is well recognized in the context of glaucoma diagnosis and management, though the extent of its importance remains debatable. Corneal biomechanical properties may be more significantly associated with glaucoma than CCT.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [31] Central corneal thickness and corneal endothelial characteristics in healthy, cataract, and glaucoma patients
    Galgauskas, Saulius
    Krasauskaite, Dalia
    Pajaujis, Mykolas
    Juodkaite, Grazina
    Asoklis, Rimvydas-Stanislovas
    [J]. CLINICAL OPHTHALMOLOGY, 2012, 6 : 1195 - 1199
  • [32] Canadian perspectives in glaucoma management: the role of central corneal thickness
    Behki, Rama
    Damji, Karim F.
    Crichton, Andrew
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2007, 42 (01): : 66 - 74
  • [33] Central corneal thickness as a risk factor for advanced glaucoma damage
    Herndon, LW
    Weizer, JS
    Stinnett, SS
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (01) : 17 - 21
  • [34] Central corneal thickness as a risk factor for advanced glaucoma damage
    Weizer, JS
    Stinnett, SS
    Herndon, LW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U284 - U284
  • [35] Central corneal thickness of normal tension glaucoma patients in Japan
    Wu, LL
    Suzuki, Y
    Ideta, R
    Araie, M
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2000, 44 (06) : 643 - 647
  • [36] Is there a relationship between central and peripheral corneal thickness in glaucoma patients?
    Fahim, MM
    Chanis, R
    Polikoff, L
    Stasi, K
    Danias, J
    Gagliuso, DJ
    Serle, JB
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U371 - U371
  • [37] Central corneal thickness, tonometry, and glaucoma risk - a guide for the perplexed
    Brandt, James D.
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2007, 42 (04): : 562 - 566
  • [38] Central corneal thickness and retrobulbar blood flow in glaucoma patients
    Katamay, R.
    Grieshaber, M. C.
    Weich, C.
    Flammer, J.
    Orguel, S.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2008, 225 (05) : 346 - 348
  • [39] Central corneal thickness and endothelial cell density in congenital glaucoma
    Guigou, S.
    Coste, R.
    Denis, D.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (05): : 509 - 514
  • [40] Why measure central corneal thickness to confirm a diagnosis of glaucoma?
    不详
    [J]. CONTACT LENS & ANTERIOR EYE, 2022, 45 (06):