Sagittal component alignment is less reliable than coronal component alignment in a Chinese population undergoing navigated TKA

被引:11
|
作者
Chen, Xiaoyong [1 ,2 ]
Wang, Huayi [1 ]
Cai, Yuanzhen [1 ]
Zhu, Qingsheng [1 ]
Zhu, Jinyu [1 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Dept Orthoped, Xian 710032, Peoples R China
[2] Xiamen Univ, Chenggong Hosp, Dept Orthoped, Xiamen 361000, Peoples R China
关键词
Total knee arthroplasty; Computer-assisted; Sagittal alignment; Navigation; TOTAL KNEE ARTHROPLASTY; TIBIAL POST IMPINGEMENT; COMPUTER-ASSISTED-NAVIGATION; ASIAN PATIENTS; REPLACEMENT; TRIAL; METAANALYSIS; CADAVER; SYSTEMS;
D O I
10.1186/s13018-014-0051-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of our study was to determine whether postoperative sagittal component alignments of primary total knee arthroplasty (TKA) using the conventional and navigated technique differed significantly. Additionally, we determined whether the use of navigation systems resulted in hyperextension of the femoral components in Chinese patients. Methods: This retrospective study reviewed 36 consecutive patients (72 knees) who underwent simultaneous bilateral primary TKAs at our hospital from February 2011 to March 2012. One knee was replaced using a computer-assisted navigation system, and the contralateral knee was replaced with the conventional technique. The radiographic and clinical results of both groups were compared. The relationship between preoperative anatomic angles and component alignments in conventional TKA and navigated TKA was examined. Results: The radiographic results showed statistically significant differences only between the navigated and conventional groups for individual femoral coronal and sagittal component alignment. Femoral sagittal component alignment showed less deviation and tended to have hyperextension using the navigated technique (-0.35 degrees) compared with the conventional technique (2.77 degrees). There was no significant difference observed for the Knee Society Score (KSS) between the two groups at 2 years postoperatively. Conclusions: The sagittal component alignment of primary TKA obtained using the conventional and navigated techniques differed significantly. Navigated TKAs resulted in a higher risk of hyperextension of the femoral components in Chinese patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Variation in Optimal Sagittal Alignment of the Femoral Component in Total Knee Arthroplasty
    Hood, Brandon
    Blum, Laura
    Holcombe, Sven A.
    Wang, Stewart C.
    Urquhart, Andrew G.
    Goulet, James A.
    Maratt, Joseph D.
    ORTHOPEDICS, 2017, 40 (02) : 102 - 106
  • [22] How to improve femoral component rotational alignment in computer-assisted TKA
    Zambianchi, F.
    Luyckx, T.
    Victor, J.
    Digennaro, V.
    Giorgini, A.
    Catani, F.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1805 - 1811
  • [23] How to improve femoral component rotational alignment in computer-assisted TKA
    F. Zambianchi
    T. Luyckx
    J. Victor
    V. Digennaro
    A. Giorgini
    F. Catani
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1805 - 1811
  • [24] The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis
    Riviere, C.
    Iranpour, F.
    Harris, S.
    Auvinet, E.
    Aframian, A.
    Chabrand, P.
    Cobb, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (07) : 1069 - 1073
  • [25] Influence of sagittal plane component alignment on kinematics after total knee arthroplasty
    Joyce Antony
    Kevin Tetsworth
    Erik Hohmann
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1686 - 1691
  • [26] Influence of sagittal plane component alignment on kinematics after total knee arthroplasty
    Antony, Joyce
    Tetsworth, Kevin
    Hohmann, Erik
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (06) : 1686 - 1691
  • [27] Articular surface mounted navigated total knee arthroplasty improves the reliability of component alignment
    N. D. Clement
    D. MacDonald
    A. G. Burgess
    C. R. Howie
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1471 - 1477
  • [28] Articular surface mounted navigated total knee arthroplasty improves the reliability of component alignment
    Clement, N. D.
    MacDonald, D.
    Burgess, A. G.
    Howie, C. R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (05) : 1471 - 1477
  • [29] The Effect of Coronal Alignment on Tibial Component Migration Following Total Knee Arthroplasty
    van Hamersveld, Koen T.
    Marang-van de Mheen, Perla J.
    Nelissen, Rob G. H. H.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (13): : 1203 - 1212
  • [30] Which method for femoral component sizing when performing kinematic alignment TKA? An in silico study
    Huang, Fasen
    Harris, Simon
    Zhou, Tianyu
    Roby, Gabriel B.
    Preston, Benjamin
    Riviere, Charles
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (02)