Electrically-receptive and thermally-responsive paper-based sensor chip for rapid detection of bacterial cells

被引:63
|
作者
Khan, Muhammad S. [1 ,2 ]
Misra, Santosh K. [1 ,2 ]
Dighe, Ketan [1 ,2 ]
Wang, Zhen [1 ,2 ]
Schwartz-Duval, Aaron S. [1 ,2 ]
Sar, Dinabandhu [1 ,2 ]
Pan, Dipanjan [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Illinois, Dept Bioengn, Urbana, IL 61801 USA
[2] Carle Fdn Hosp, Biomed Res Ctr, Urbana, IL 61801 USA
[3] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[4] Univ Illinois, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[5] Carle Illinois Coll Med, Urbana, IL 61801 USA
来源
BIOSENSORS & BIOELECTRONICS | 2018年 / 110卷
基金
美国国家科学基金会;
关键词
Bacterial sensor; Filter paper; PNIPAm; Graphene; Lake water; Milk; ESCHERICHIA-COLI O157-H7; SURFACE-PLASMON RESONANCE; LABEL-FREE DETECTION; UNITED-STATES; BIOMEDICAL APPLICATIONS; LISTERIA-MONOCYTOGENES; COLORIMETRIC DETECTION; CONDUCTIVE POLYMERS; FOODBORNE ILLNESS; SALMONELLA SPP;
D O I
10.1016/j.bios.2018.03.044
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although significant technological advancements have been made in the development of analytical biosensor chips for detecting bacterial strains (E. coli, S. Mutans and B. Subtilis), critical requirements i.e. limit of detection (LOD), fast time of response, ultra-sensitivity with high reproducibility and good shelf-life with robust sensing capability have yet to be met within a single sensor chip. In order to achieve these criteria, we present an electrically-receptive thermally-responsive (ER-TR) sensor chip comprised of simple filter paper used as substrate coated with composite of poly(N-isopropylacrylamide) polymer (PNIPAm) - graphene nanoplatelet (GR) followed by evaporation of Au electrodes for capturing both Gram-positive (S. mutans and B. subtilis) and Gramnegative (E. coli) bacterial cells in real-time. Autoclave water, tap water, lake water and milk samples were tested with ER-TR chip with and without bacterial strains at varying concentration range 10(1)-10(5) cells/mL. The sensor was integrated with in-house built printed circuit board (PCB) to transmit/receive electrical signals. The interaction of E. coli, S. mutans and B. subtilis cells with fibers of PNIPAm-GR resulted in a change of electrical resistance and the readout was monitored wirelessly in real-time using MATLAB algorithm. Finally, prepared ERTR chip exhibited the reproducibility of 85-97% with shelf-life of up to four weeks after testing with lake water sample.
引用
收藏
页码:132 / 140
页数:9
相关论文
共 36 条
  • [31] Flexible paper-based AuNP sensor for rapid detection of diabenz (a,h) anthracene (DbA) and benzo(b)fluoranthene (BbF) in mussels coupled with deep learning algorithms
    Adade, Selorm Yao-Say Solomon
    Lin, Hao
    Nunekpeku, Xorlali
    Johnson, Nana Adwoa Nkuma
    Agyekum, Akwasi Akomeah
    Zhao, Songguang
    Teye, Ernest
    Qianqian, Sun
    Kwadzokpui, Bridget Ama
    Ekumah, John-Nelson
    Li, Huanhuan
    Chen, Quansheng
    FOOD CONTROL, 2025, 168
  • [32] Stimuli-responsive fluorescent polymer nanoparticles: Versatile applications in rapid colorimetric and fluorometric detection of cyanide in blood plasma, pH sensing, paper-based sensors, and intelligent artworks
    Norouzi, Mastaneh
    Ahmadi, Ebrahim
    Mohamadnia, Zahra
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2024, 452
  • [33] Electrochemical- and Fluorescent-Mediated Signal Amplifications for Rapid Detection of Low-Abundance Circulating Tumor Cells on a Paper-Based Microfluidic Immunodevice
    Wu, Yafeng
    Xue, Peng
    Hui, Kam M.
    Kang, Yuejun
    CHEMELECTROCHEM, 2014, 1 (04): : 722 - 727
  • [34] Origami chips: Development and validation of a paper-based Lab-on-a-Chip device for the rapid and cost-effective detection of 4-methylmethcathinone (mephedrone) and its metabolite, 4-methylephedrine in urine
    McNeill, Lauren
    Pearson, Catherine
    Megson, David
    Norrey, John
    Watson, Danielle
    Ashworth, David
    Linton, Patricia E.
    Sutcliffe, Oliver B.
    Shaw, Kirsty J.
    FORENSIC CHEMISTRY, 2021, 22
  • [35] Enhanced and rapid detection of mercury ions using one-step microwave synthesized fluorescent carbon quantum dots: Development of a very simple paper-based sensor with detailed mechanistic insights
    Rizvi, Afsar H.
    Fatima, Reesha
    Ahmad, Absar
    Aziz, Mohd. Azhar
    MICROCHEMICAL JOURNAL, 2025, 208
  • [36] MoOx quantum dots with peroxidase-like activity on microfluidic paper-based analytical device for rapid colorimetric detection of H2O2 released from PC12 cells
    Liu, Meng-Meng
    Li, Shan-Hong
    Huang, Dan-Dan
    Xu, Zhi-Wei
    Wu, Ya-Wei
    Lei, Yun
    Liu, Ai-Lin
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 305