Diagnostic accuracy of tissue Doppler echocardiography for patients with acute heart failure

被引:19
|
作者
Huang, C-H
Tsai, M-S
Hsieh, C-C
Wang, T-D
Chang, W-T
Chen, W-J
机构
[1] Natl Taiwan Univ Hosp, Dept Emergency Med, Taipei, Taiwan
[2] Natl Taiwan Univ, Coll Med, Dept Emergency Med, Taipei, Taiwan
[3] Natl Taiwan Univ, Coll Med, Dept Internal Med Cardiol, Taipei, Taiwan
关键词
D O I
10.1136/hrt.2006.089516
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Acute heart failure leads to high mortality and morbidity rates. The symptom of acute dyspnoea is non-specific and the diagnostic tools of acute heart failure are still not satisfactory. Tissue Doppler echocardiography is accurate in evaluating cardiac function; however, its efficacy in diagnosing patients with acute dyspnoea in emergency departments remains unclear. Methods: Patients with acute dyspnoea were included prospectively while visiting the emergency department. Tissue Doppler echocardiography was carried out and the ratios of peak early diastolic transmitral blood flow velocity (E) to the peak early diastolic tissue velocity over mitral annulus (Ea) were recorded. The sensitivity, specificity and accuracy of tissue Doppler parameters and the receiver-operating characteristic curves for diagnosing acute heart failure were also evaluated. Results: A total of 92 patients were enrolled. The ratio E: Ea was found to be a good diagnostic test to estimate the diagnostic performances of tissue Doppler echocardiography using receiver-operating characteristic curves in cases of acute heart failure in patients with preserved left ventricular systolic function (mean (SD) area under the curve = 0.875 (0.049); p < 0.001; cut-off value = 11) and with left ventricular systolic dysfunction (mean (SD) area under the curve = 0.903 (0.061); p = 0.003; cut-off value = 16). E: Ea was an independent predictor of acute heart failure in multiple logistic regressions. For patients with a B-type natriuretic peptide level between 100 and 500 pg/ml, E:Ea provided an accuracy of 90.9% (p = 0.015) for diagnosing acute heart failure. Conclusions: Tissue Doppler echocardiography is accurate in diagnosing patients with acute heart failure in emergency departments. It can be a useful supplementary diagnostic tool for patients with inconclusive blood B-type natriuretic peptide level.
引用
收藏
页码:1790 / 1794
页数:5
相关论文
共 50 条
  • [41] Diagnostic usefulness and prognostic impact of tissue Doppler imaging in heart failure patients with significant secondary mitral regurgitation
    Bruch, Christian
    Gradaus, Rainer
    Sindermann, Jurgen
    Breithardt, Gunter
    CIRCULATION, 2007, 116 (16) : 715 - 715
  • [42] Diagnostic Accuracy of Fetal Echocardiography in Congenital Heart Disease
    Mozumdar, Namrita
    Rowland, John
    Pan, Stephanie
    Rajagopal, Hari
    Geiger, Miwa K.
    Srivastava, Shubhika
    Stern, Kenan W. D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (11) : 1384 - 1390
  • [43] Feasibility and Diagnostic Accuracy of Handheld Echocardiography in Patients Hospitalized With Acute Coronary Syndrome
    Geers, Jolien
    Molek, Patrycja
    Balfour, Amy
    Botezatu, Simona
    Joshi, Shruti S.
    White, Audrey
    McCarley, Joanne
    Everett, Russell
    Martin, Gillian
    Cusack, David
    Cosyns, Bernard
    Newby, David E.
    Dweck, Marc R.
    CIRCULATION, 2023, 148
  • [44] Walking the tightrope: Using quantitative Doppler echocardiography to optimize ventricular filling pressures in patients hospitalized for acute heart failure
    Lei, Juan
    Dhamoon, Amit S.
    Wang, Jingfeng
    Iannuzzi, Michael
    Liu, Kan
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2016, 5 (02) : 130 - 140
  • [45] Diagnostic accuracy of inferior vena cava evaluation in the diagnosis of acute heart failure among dyspneic patients
    Sforza, Alfonso
    Carlino, Maria Viviana
    Guarino, Mario
    Fucile, Ilaria
    De Luca, Nicola
    Mancusi, Costantino
    MONALDI ARCHIVES FOR CHEST DISEASE, 2020, 90 (04) : 704 - 707
  • [46] Diagnostic value of Doppler transthoracic echocardiography in the estimation of left ventricular filling pressure in patients with severe symptomatic systolic heart failure
    Gellen, B.
    Lesault, P. F.
    Poitrine, F. Canoui
    Lim, P.
    Gueret, P.
    Teiger, E.
    Rande, J. L. Dubois
    Hittinger, L.
    Damy, T.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 : 780 - 781
  • [47] Diagnostic value of Doppler transthoracic echocardiography in the estimation of left ventricular filling pressure in patients with severe symptomatic systolic heart failure
    Gellen, B.
    Lesault, P. F.
    Poitrine, F. Canoui
    Lim, P.
    Gueret, P.
    Teiger, E.
    Rande, J. L. Dubois
    Hittinger, L.
    Damy, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 780 - 781
  • [48] Diagnostic accuracy of fibroblast growth factor 23 for predicting acute kidney injury in patients with acute decompensated heart failure
    Pramong, Nattha
    Gojaseni, Pongsathorn
    Suttipongkeat, Sarunyoo
    Kiattisunthorn, Kraiwiporn
    Chittinandana, Anutra
    NEPHROLOGY, 2021, 26 (02) : 126 - 133
  • [49] The prognostic value of a new tissue Doppler parameter in patients with heart failure
    Mornos, Cristian
    Petrescu, Lucian
    Ionac, Adina
    Cozma, Dragos
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01): : 47 - 55
  • [50] Tissue Doppler imaging in patients with congestive heart failure and conduction disorders
    Faber, L
    Lamp, B
    Vogt, J
    Horstkotte, D
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2004, 6 (0D) : D10 - D15