Myocardial distributionof 18F-FDG and 99mTc-sestamibi on dual-isotope simultaneous acquisition SPET compared with PET

被引:22
|
作者
Matsunari, I
Kanayama, S
Yoneyama, T
Matsudaira, M
Nakajima, K
Taki, K
Nekolla, SG
Takekoshi, N
Tonami, N
Hisada, K
机构
[1] Med & Pharmacol Res Ctr Fdn, Hakui, Ishikawa 9250613, Japan
[2] Kanazawa Med Univ, Dept Cardiol, Kanazawa, Ishikawa, Japan
[3] Kanazawa Univ, Sch Med, Dept Nucl Med, Kanazawa, Ishikawa 920, Japan
[4] Tech Univ Munich, Nukl Med Klin & Poliklin, D-8000 Munich, Germany
关键词
SPET; PET; F-18-FDG;
D O I
10.1007/s00259-002-0889-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dual-isotope simultaneous acquisition (DISA) single-photon emission tomography (SPET) protocol with fluorine-18 fluorodeoxyglucose (F-18-FDG) and a technetium-99m labelled flow tracer is attractive because it permits assessment of both myocardial glucose utilisation and flow within a single study. Differences in physical and physiological characteristics between F-18-FDG and the Tc-99m-labelled flow tracer, however, may cause differences in myocardial activity distribution between the agents. The aim of this study was to investigate the relation between the myocardial distribution of F-18-FDG and a Tc-99m-labelled flow tracer on DISA SPET in comparison with nitrogen-13 ammonia/F-18-FDG positron emission tomography (PET). Nine normal volunteers without cardiac disease and ten patients with known coronary artery disease (CAD) underwent N-13-ammonia/F-18-FDG PET and Tc-99m-sestamibi/F-18-FDG DISA SPET. Using a semiquantitative polar map approach, the left ventricular myocardium was divided into nine segments, and relative regional activity was calculated for each segment. A segment was considered to have concordant uptake between F-18-FDG and flow tracer if the difference in measured regional activity between the tracers was : 10% of peak activity, and the percentage of concordant segments was calculated for each subject. There was a good overall concordance of myocardial activity between the agents on DISA SPET (84.0% +/- 14.8%) in normals, which was comparable to that seen on PET (86.4% +/- 14.5%, NS vs DISA SPET). However, the myocardial activity distributions of F-18-FDG and flow tracer were not identical in that reduced flow tracer activity was seen in the basal segments on DISA SPET in both normals and CAD patients. It is concluded that there is good overall concordance of activity between F-18-FDG and flow tracer in normal myocardium on DISA SPET, which is comparable to that on PET, supporting the use of combined Tc-99m-flow tracer/F-18-FDG imaging for the detection of viable myocardium. However, there is a difference in the myocardial activity distribution between the agents in both normals and CAD patients, the difference being particularly evident in the basal segments. Therefore, careful image interpretation that takes into consideration the different normal activity distribution between the tracers and/or a tracer-specific normal database is necessary for comparison with patient studies.
引用
收藏
页码:1357 / 1364
页数:8
相关论文
共 50 条
  • [11] 18F-FDG PET and 99mTc-sestamibi scintimammography for monitoring breast cancer response to neoadjuvant chemotherapy: a comparative study
    Reinhold Tiling
    Rainer Linke
    Michael Untch
    Almuth Richter
    Siegrid Fieber
    Kirsten Brinkbäumer
    Klaus Tatsch
    Klaus Hahn
    European Journal of Nuclear Medicine, 2001, 28 : 711 - 720
  • [12] Distant subcutaneous recurrence of a parathyroid carcinoma: abnormal uptakes in the 99mTc-sestamibi scan and 18F-FDG PET/CT imaging
    Kim, Sang Soo
    Jeon, Yun Kyung
    Lee, Soo Hyung
    Kim, Bo Hyun
    Kim, Seong Jang
    Kim, Yong Ki
    Kim, In Ju
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2014, 29 (03): : 383 - 387
  • [13] Molecular imaging of angiogenesis after myocardial infarction by 111In-DTPA-cNGR and 99mTc-sestamibi dual-isotope myocardial SPECT
    Hendrikx, Geert
    De Saint-Hubert, Marijke
    Dijkgraaf, Ingrid
    Bauwens, Matthias
    Douma, Kim
    Wierts, Roel
    Pooters, Ivo
    Van den Akker, Nynke M. S.
    Hackeng, Tilman M.
    Post, Mark J.
    Mottaghy, Felix M.
    EJNMMI RESEARCH, 2015, 5 : 13 - 22
  • [14] Molecular imaging of angiogenesis after myocardial infarction by 111In-DTPA-cNGR and 99mTc-sestamibi dual-isotope myocardial SPECT
    Geert Hendrikx
    Marijke De Saint-Hubert
    Ingrid Dijkgraaf
    Matthias Bauwens
    Kim Douma
    Roel Wierts
    Ivo Pooters
    Nynke MS Van den Akker
    Tilman M Hackeng
    Mark J Post
    Felix M Mottaghy
    EJNMMI Research, 5
  • [15] Comparison of Dual-Isotope 99mTc-Sestamibi/123I-Iodide Subtraction Planar and Dual-Isotope Subtraction SPECT Imaging for Hyperparathyroidism
    Dennis, J. L.
    Bolster, A. A.
    Neilly, J. B.
    Poon, F. W.
    Han, S.
    Gardner, G. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S167 - S167
  • [16] Clinical significance of dual time point 99mTc-sestamibi breast-specific gamma imaging and 18F-FDG PET/CT for discriminating breast cancer
    Yoo, Jang
    Kiml, Born Sahn
    Yooni, Hai-Jeon
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [17] Feasibility of simultaneous stress 99mTc-sestamibi/rest 201T1 dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease
    Nakamura, M
    Takeda, K
    Ichihara, T
    Motomura, N
    Shimizu, H
    Saito, Y
    Nomura, Y
    Isaka, N
    Konishi, T
    Nakano, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (06) : 895 - 903
  • [18] Feasibility and image quality of dual-isotope SPECT using 18F-FDG and 99mTc-tetrofosmin after acipimox administration
    Kam, BLR
    Valkema, R
    Poldermans, D
    Bax, JJ
    Reijs, AEM
    Rambaldi, R
    Boersma, E
    Rieveld, T
    Roelandt, JRTC
    Krenning, EP
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (02) : 140 - 145
  • [19] Feasibility of simultaneous dual-isotope myocardial perfusion acquisition using a lower dose of sestamibi
    Kwok, CG
    Wu, S
    Tsang, HP
    Strauss, HW
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03): : 281 - 285
  • [20] Optimization of acquisition parameters for simultaneous 201Tl and 99mTc dual-isotope myocardial imaging
    Wang, WT
    Tsui, BMW
    Lalush, DS
    Tocharoenchai, C
    Frey, EC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1227 - 1235