Myocardial distributionof 18F-FDG and 99mTc-sestamibi on dual-isotope simultaneous acquisition SPET compared with PET

被引:22
|
作者
Matsunari, I
Kanayama, S
Yoneyama, T
Matsudaira, M
Nakajima, K
Taki, K
Nekolla, SG
Takekoshi, N
Tonami, N
Hisada, K
机构
[1] Med & Pharmacol Res Ctr Fdn, Hakui, Ishikawa 9250613, Japan
[2] Kanazawa Med Univ, Dept Cardiol, Kanazawa, Ishikawa, Japan
[3] Kanazawa Univ, Sch Med, Dept Nucl Med, Kanazawa, Ishikawa 920, Japan
[4] Tech Univ Munich, Nukl Med Klin & Poliklin, D-8000 Munich, Germany
关键词
SPET; PET; F-18-FDG;
D O I
10.1007/s00259-002-0889-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dual-isotope simultaneous acquisition (DISA) single-photon emission tomography (SPET) protocol with fluorine-18 fluorodeoxyglucose (F-18-FDG) and a technetium-99m labelled flow tracer is attractive because it permits assessment of both myocardial glucose utilisation and flow within a single study. Differences in physical and physiological characteristics between F-18-FDG and the Tc-99m-labelled flow tracer, however, may cause differences in myocardial activity distribution between the agents. The aim of this study was to investigate the relation between the myocardial distribution of F-18-FDG and a Tc-99m-labelled flow tracer on DISA SPET in comparison with nitrogen-13 ammonia/F-18-FDG positron emission tomography (PET). Nine normal volunteers without cardiac disease and ten patients with known coronary artery disease (CAD) underwent N-13-ammonia/F-18-FDG PET and Tc-99m-sestamibi/F-18-FDG DISA SPET. Using a semiquantitative polar map approach, the left ventricular myocardium was divided into nine segments, and relative regional activity was calculated for each segment. A segment was considered to have concordant uptake between F-18-FDG and flow tracer if the difference in measured regional activity between the tracers was : 10% of peak activity, and the percentage of concordant segments was calculated for each subject. There was a good overall concordance of myocardial activity between the agents on DISA SPET (84.0% +/- 14.8%) in normals, which was comparable to that seen on PET (86.4% +/- 14.5%, NS vs DISA SPET). However, the myocardial activity distributions of F-18-FDG and flow tracer were not identical in that reduced flow tracer activity was seen in the basal segments on DISA SPET in both normals and CAD patients. It is concluded that there is good overall concordance of activity between F-18-FDG and flow tracer in normal myocardium on DISA SPET, which is comparable to that on PET, supporting the use of combined Tc-99m-flow tracer/F-18-FDG imaging for the detection of viable myocardium. However, there is a difference in the myocardial activity distribution between the agents in both normals and CAD patients, the difference being particularly evident in the basal segments. Therefore, careful image interpretation that takes into consideration the different normal activity distribution between the tracers and/or a tracer-specific normal database is necessary for comparison with patient studies.
引用
收藏
页码:1357 / 1364
页数:8
相关论文
共 50 条
  • [1] Myocardial distribution of 18F-FDG and 99mTc-sestamibi on dual-isotope simultaneous acquisition SPET compared with PET
    Ichiro Matsunari
    Sugako Kanayama
    Tatsuya Yoneyama
    Masamichi Matsudaira
    Kenichi Nakajima
    Junichi Taki
    Stephan G. Nekolla
    Noboru Takekoshi
    Norihisa Tonami
    Kinichi Hisada
    European Journal of Nuclear Medicine and Molecular Imaging, 2002, 29 : 1357 - 1364
  • [2] Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study
    Matsunari, I
    Kanayama, S
    Yoneyama, T
    Matsudaira, M
    Nakajima, K
    Taki, J
    Nekolla, S
    Tonami, N
    Hisada, K
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (02) : 195 - 202
  • [3] Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study
    Ichiro Matsunari
    Sugako Kanayama
    Tatsuya Yoneyama
    Masamichi Matsudaira
    Kenichi Nakajima
    Junichi Taki
    Stephan G. Nekolla
    Norihisa Tonami
    Kinichi Hisada
    European Journal of Nuclear Medicine and Molecular Imaging, 2005, 32 : 195 - 202
  • [4] Performing 18F-FDG PET studies following injections of 99mTc-sestamibi
    Division of Nuclear Medicine, Department of Radiology, University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, United States
    Phys Med Biol, 6 (1439-1453):
  • [5] Performing 18F-FDG PET studies following injections of 99mTc-sestamibi
    Smith, RJ
    Karp, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (06): : 1439 - 1453
  • [6] Comparison of 18F-fluorodeoxyglucose (FDG) 99mTc-sestamibi (MIBI) dual isotope simultaneous aqcuisition (DISA) SPECT and rest-stress 99mTc-sestamibi SPECT.
    de Boer, J
    Blanksma, PK
    Willemsen, ATM
    Jager, PL
    Paans, AMJ
    Siebelink, HJ
    Vaalburg, W
    Piers, DA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 89P - 90P
  • [7] Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability
    De Boer, J
    Slart, RHJA
    Blanksma, PK
    Willemsen, ATM
    Jager, PL
    Paans, AMJ
    Vaalburg, W
    Piers, DA
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (03) : 251 - 257
  • [8] Synchronous Metastatic Breast Carcinoma and Parathyroid Adenoma on 18F-FDG PET/CT and 99mTc-Sestamibi Imaging
    Singh, Harkamal
    Wale, Daniel J.
    Wong, Ka Kit
    Gross, Milton D.
    Viglianti, Benjamin L.
    CLINICAL NUCLEAR MEDICINE, 2019, 44 (02) : 148 - 149
  • [9] 18F-FDG PET and 99mTc-sestamibi scintimammography for monitoring breast cancer response to neoadjuvant chemotherapy:: a comparative study
    Tiling, R
    Linke, R
    Untch, M
    Richter, A
    Fieber, S
    Brinkbäumer, K
    Tatsch, K
    Hahn, K
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (06) : 711 - 720
  • [10] The role of 99mTc-Sestamibi SPECT/CT and 18F-FDG PET/CT in diagnosis of Multiple Endocrine Neoplasia Syndromes
    He, H.
    Zhang, M.
    Guo, R.
    Li, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S466 - S466