An MR-Conditional High-Torque Pneumatic Stepper Motor for MRI-Guided and Robot-Assisted Intervention

被引:43
|
作者
Chen, Yue [1 ]
Kwok, Ka-Wai [1 ,2 ,3 ]
Tse, Zion Tsz Ho [1 ]
机构
[1] Univ Georgia, Coll Engn, Athens, GA 30602 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
[3] Univ Hong Kong, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
基金
美国国家卫生研究院;
关键词
MRI; Pneumatic stepper motor; MR-conditional; IN-VIVO; PERFORMANCE; DEVICE; OTTO;
D O I
10.1007/s10439-014-1049-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging allows for visualizing detailed pathological and morphological changes of soft tissue. MR-conditional actuations have been widely investigated for development of image-guided and robot-assisted surgical devices under the Magnetic resonance imaging (MRI). This paper presents a simple design of MR-conditional stepper motor which can provide precise and high-torque actuation without adversely affecting the MR image quality. This stepper motor consists of two MR-conditional pneumatic cylinders and the corresponding supporting structures. Alternating the pressurized air can drive the motor to rotate each step in 3.6A degrees with the motor coupled to a planetary gearbox. Experimental studies were conducted to validate its dynamics performance. Maximum 800 mN m output torque is achieved. The motor accuracy independently varied by two factors: motor operating speed and step size, was also investigated. The motor was tested within a 3T Siemens MRI scanner (MAGNETOM Skyra, Siemens Medical Solutions, Erlangen, Germany) and a 3T GE MRI scanner (GE SignaHDx, GE Healthcare, Milwaukee, WI, USA). The image artifact and the signal-to-noise ratio (SNR) were evaluated for study of its MRI compliancy. The results show that the presented pneumatic stepper motor generated 2.35% SNR reduction in MR images. No observable artifact was presented besides the motor body itself. The proposed motor test also demonstrates a standard to evaluate the pneumatic motor capability for later incorporation with motorized devices used under MRI.
引用
收藏
页码:1823 / 1833
页数:11
相关论文
共 24 条
  • [21] Robot-assisted, real-time, MRI-guided laser interstitial thermal therapy for pediatric patients with hypothalamic hamartoma: surgical technique, pitfalls, and initial results
    Candela-Canto, Santiago
    Muchart, Jordi
    Ramirez-Camacho, Alia
    Becerra, Victoria
    Alamar, Mariana
    Pascual, Anna
    Forero, Carolina
    Rebollo Polo, Monica
    Munuera, Josep
    Aparicio, Javier
    Rumia, Jorda
    Hinojosa, Jose
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2022, 29 (06) : 681 - 692
  • [22] Stereotactic robot-assisted MRI-guided laser interstitial thermal therapy thalamotomy for medically intractable Parkinson’s disease tremor: technical note and preliminary effects on 2 cases
    Mickael Aubignat
    Mélissa Tir
    Martial Ouendo
    Jean-Marc Constans
    Michel Lefranc
    Acta Neurochirurgica, 2023, 165 : 1453 - 1460
  • [23] Stereotactic robot-assisted MRI-guided laser interstitial thermal therapy thalamotomy for medically intractable Parkinson's disease tremor: technical note and preliminary effects on 2 cases
    Aubignat, Mickael
    Tir, Melissa
    Ouendo, Martial
    Constans, Jean-Marc
    Lefranc, Michel
    ACTA NEUROCHIRURGICA, 2023, 165 (06) : 1453 - 1460
  • [24] Comparison of Heart Rate Reserve-Guided and Ratings of Perceived Exertion-Guided Methods for High-Intensity Robot-Assisted Gait Training in Patients With Chronic Stroke Focused on the Motor Function and Gait Ability
    Bae, Young-Hyeon
    Kim, Yun-Hee
    Fong, Shirley S. M.
    TOPICS IN GERIATRIC REHABILITATION, 2016, 32 (02) : 119 - 126