A rule-based phonocardiographic method for long-term fetal heart rate monitoring

被引:67
|
作者
Kovács, F
Török, M
Habermajer, I
机构
[1] Tech Univ Budapest, H-1111 Budapest, Hungary
[2] Haynal I Univ Hlth Care, Budapest, Hungary
关键词
fetal heart rate; fetal heart sounds; fetal monitoring; fetal phonocardiography;
D O I
10.1109/10.817627
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A real-time method for fetal heart rate (FHR) monitoring based on signal processing of the fetal heart sounds is presented. The acoustic method, which utilizes an adaptive time pattern analysis to select and analyze those heartbeats that can be recorded without artefact, is guided by a number of rules involving an introduced confidence factor on the timing prediction. The algorithm was implemented in a low-power portable electronic instrument to enable long-term fetal surveillance. A large number of clinical tests have shown the very good performance of the phonocardiographic method in comparison with FHR curves simultaneously recorded with ultrasound cardiotocography. Indeed, approximately 90% of the time, the acoustic FHR curve remained inside a +/-3 beats/min tolerance limit of the reference ultrasound method. The confidence was typically CF > 0.85. The acoustic method exceeded a +/-5 beats/min limit relative to the ultrasound method approximately 5% of the time. Finally, no relevant FHR data was measured approximately 5% of the time.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 50 条
  • [21] The technique and algorithms for computerized analysis of long-term fetal heart rate recordings
    Dobbe, JGG
    Lunshof, S
    Boer, K
    Wolf, H
    Grimbergen, CA
    PRENATAL AND NEONATAL MEDICINE, 2001, 6 (05): : 280 - 289
  • [22] FETAL HEART RATE VARIABILITY ANALYSIS FROM PHONOCARDIOGRAPHIC RECORDINGS
    Chourasia, Vijay S.
    Tiwari, Anil Kumar
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2011, 11 (05) : 1315 - 1331
  • [23] MORE PERINATAL DEATHS ASSOCIATED WITH POOR LONG-TERM VARIABILITY DURING ANTENATAL FETAL HEART-RATE MONITORING
    ODENDAAL, HJ
    SOUTH AFRICAN MEDICAL JOURNAL, 1990, 77 (10): : 506 - 508
  • [24] THE FEASIBILITY OF LONG-TERM FETAL HEART-RATE MONITORING IN THE HOME-ENVIRONMENT USING MATERNAL ABDOMINAL ELECTRODES
    CROWE, JA
    HARRISON, A
    HAYESGILL, BR
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (03) : 195 - 202
  • [25] NEW METHOD OF FETAL HEART-RATE MONITORING
    LEVENTHAL, JM
    BROWN, WU
    WEISS, JB
    ALPER, MH
    OBSTETRICS AND GYNECOLOGY, 1975, 45 (05): : 494 - 500
  • [26] Development of very long-term ambulatory monitoring system for heart rate variability
    Yamamoto, Y
    Aoyagi, N
    Ohashi, K
    Tomono, S
    FASEB JOURNAL, 1999, 13 (05): : A746 - A746
  • [27] A Phonocardiographic-Based Fiber-Optic Sensor and Adaptive Filtering System for Noninvasive Continuous Fetal Heart Rate Monitoring
    Martinek, Radek
    Nedoma, Jan
    Fajkus, Marcel
    Kahankova, Radana
    Konecny, Jaromir
    Janku, Petr
    Kepak, Stanislav
    Bilik, Petr
    Nazeran, Homer
    SENSORS, 2017, 17 (04)
  • [28] GOOD LONG-TERM VARIABILITY OF THE FETAL HEART-RATE - AN ACCURATE INDICATION OF FETAL WELL-BEING
    ALBERTYN, M
    ODENDAAL, HJ
    SOUTH AFRICAN MEDICAL JOURNAL, 1989, 75 (03): : 148 - 148
  • [29] The fetal heart in gestational diabetes: long-term effects
    Hod, M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2021, 128 (02) : 280 - 280
  • [30] Long-Term Heart Rate Variability Assessment
    Penhaker, M.
    Stula, T.
    Augustynek, M.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 532 - 535