Effect of sample solvent on the chromatographic peak shape of analytes eluted under reversed-phase liquid chromatogaphic conditions

被引:86
|
作者
Keunchkarian, Sonia
Reta, Mario
Romero, Lilian
Castells, Cecilia [1 ]
机构
[1] Natl Univ La Plata, Fac Ciencias Exactas, Div Quim Anal, RA-1900 La Plata, Argentina
[2] Natl Univ La Plata, Fac Ciencias Exactas, CIDEPINT, RA-1900 La Plata, Argentina
关键词
injection solvent; viscosity mismatch; injection volume; loop volume;
D O I
10.1016/j.chroma.2006.02.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peak-shape problems represent the most common troubles in liquid chromatography. Distorted peaks are causes for integration problems, and very often for poor resolutions. Sample and standard solvent different from that of the eluent is one of the possible reasons for anomalous peak-shapes. The injection of a pulse of different viscosity from that of the mobile phase is the underlying cause of distortions in early eluting bands. Strong eluting solvents (of exactly equal viscosity coefficients) are cause of band broadening, not of peak distortions. The goal of the present work is to critically evaluate the significant role of sample solvent upon the chromatographic band distortion. Practical solutions for situations where chromatographic analysis is performed under conditions far from ideal as a result of time constrains related to sample preparation are also discussed. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 50 条
  • [31] Effect of long-term storage and use on the properties of reversed-phase liquid chromatographic columns
    Haghedooren, Erik
    Farkas, Edit
    Kerner, Agnes
    Dragovic, Sanja
    Noszal, Bela
    Hoogmartens, Jos
    Adams, Erwin
    TALANTA, 2008, 76 (01) : 172 - 182
  • [32] Multicomponent (n ≥ 3) Sorption Isotherms in Reversed-Phase Liquid Chromatography: The Effect of Immobilized Eluent on the Retention of Analytes
    Mallette, Jennifer
    Wang, Mei
    Parcher, Jon F.
    ANALYTICAL CHEMISTRY, 2010, 82 (08) : 3329 - 3336
  • [33] EFFECTS OF AMINE MODIFIERS ON RETENTION AND PEAK SHAPE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KIEL, JS
    MORGAN, SL
    ABRAMSON, RK
    JOURNAL OF CHROMATOGRAPHY, 1985, 320 (02): : 313 - 323
  • [34] PROPOSED MODEL FOR PEAK SPLITTING IN REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COMPUTER-PREDICTION OF ELUTED PEAK PROFILES
    LOW, GKC
    HADDAD, PR
    DUFFIELD, AM
    JOURNAL OF CHROMATOGRAPHY, 1984, 336 (01): : 15 - 24
  • [35] Change in Chromatographic Parameters of Some Phenylpropanoids in Different Mobile Phases Under Reversed-Phase HPLC Conditions
    Abramov, O. K.
    Ryabukha, A. F.
    Pletneva, I. V.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2024, 58 (01) : 138 - 141
  • [36] INFLUENCE OF ORGANIC-SOLVENT MODIFIER AND SOLVENT STRENGTH ON PEAK SHAPE OF SOME BASIC COMPOUNDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A REVERSED-PHASE COLUMN
    MCCALLEY, DV
    JOURNAL OF CHROMATOGRAPHY A, 1995, 708 (02) : 185 - 194
  • [37] Chromatographic properties of reversed-phase stationary phases under pressure- and electro-driven conditions
    Jiskra, J
    Cramers, CA
    Byelik, M
    Claessens, HA
    JOURNAL OF CHROMATOGRAPHY A, 1999, 862 (02) : 121 - 135
  • [38] EFFECT OF THE SAMPLE SOLVENT ON BAND PROFILES IN PREPARATIVE LIQUID-CHROMATOGRAPHY USING NONAQUEOUS REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    JANDERA, P
    GUIOCHON, G
    JOURNAL OF CHROMATOGRAPHY, 1991, 588 (1-2): : 1 - 14
  • [39] Column selectivity in reversed-phase liquid chromatography II. Effect of a change in conditions
    Wilson, NS
    Nelson, MD
    Dolan, JW
    Snyder, LR
    Carr, PW
    JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) : 195 - 215
  • [40] THERMODYNAMIC STUDY OF THE RETENTION OF AROMATIC HYDROCARBONS ON PHENYLSILICAGEL BASED STATIONARY PHASE UNDER REVERSED-PHASE LIQUID CHROMATOGRAPHIC MECHANISM
    Soare, Andreia-Cristina
    Meltzer, Viorica
    Cheregi, Mihaela
    David, Victor
    REVUE ROUMAINE DE CHIMIE, 2019, 64 (12) : 1083 - 1089