Biological and physical mechanisms of HIFU-induced hyperecho in ultrasound images

被引:91
|
作者
Rabkin, Brian A.
Zderic, Vfsna
Crum, Lawrence A.
Vaezy, Shahram
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Appl Phys Lab, Seattle, WA 98195 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2006年 / 32卷 / 11期
基金
美国国家科学基金会; 美国国家航空航天局;
关键词
ultrasound; microbubbles; HIFU; therapy; hyperecho; bicieffects; targeting; monitoring; imaging;
D O I
10.1016/j.ultrasmedbio.2006.04.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Guidance and monitoring of high intensity focused ultrasound (HIFU) therapy, using ultrasound imaging, has primarily utilized formation of a hyperechoic region at the HIFU focus. We investigated biologic and physical mechanisms of a hyperecho, as well as safety of this phenomenon, using thermal, acoustic and light microscopy observations. Single, short-duration HIFU pulses (30-60 ms) were able to produce a hyperechoic region at the HIFU focus, 2 cm deep in a rabbit thigh muscle. When hyperechoic regions appeared, inertial cavitation was detected in vivo using a custom-made passive cavitation detection system. Light micrographs showed a large number of cavities (approximately 100/mm(3)), 1-10 mu m in diameter, in a cytoplasm of cells located at the HIFU focus. Blood congestion was observed around a focal region, indicating an injury of microvasculature. Cellular necrosis was observed at 2 d after the treatment, while healing, scar tissue formation and regeneration were observed at 7 d and 14 d. The results indicate that a possibility of adverse tissue effects has to be taken into consideration when the hyperecho formation, induced by very-short HIFU pulses, is used for pretreatment targeting.
引用
收藏
页码:1721 / 1729
页数:9
相关论文
共 50 条
  • [21] A fast tissue stiffness-dependent elastography for HIFU-induced lesions inspection
    Zhang, Dachun
    Zhang, Siyuan
    Wan, Mingxi
    Wang, Supin
    ULTRASONICS, 2011, 51 (08) : 857 - 869
  • [22] Investigation of HIFU-induced anti-tumor immunity in a murine tumor model
    Zhenlin Hu
    Xiao Yi Yang
    Yunbo Liu
    Georgy N Sankin
    Eric C Pua
    Michael A Morse
    H Kim Lyerly
    Timothy M Clay
    Pei Zhong
    Journal of Translational Medicine, 5
  • [23] Can color doppler predict the uniformity of HIFU-induced prostate tissue destruction?
    Rouvière, O
    Curiel, L
    Chapelon, JY
    Bouvier, R
    Ecochard, R
    Gelet, A
    Lyonnet, D
    PROSTATE, 2004, 60 (04): : 289 - 297
  • [24] Characterization of the HIFU-induced cloud cavitation for the optimization of high pressure concentration for lithotripsy
    Ikeda, Teiichiro
    Yoshizawa, Shin
    Kaneko, Yukio
    Matsumoto, Yoichiro
    THERAPEUTIC ULTRASOUND, 2006, 829 : 328 - +
  • [25] REAL-TIME PASSIVE ACOUSTIC MONITORING OF HIFU-INDUCED TISSUE DAMAGE
    Nandlall, Sacha D.
    Jackson, Edward
    Coussios, Constantin-C.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (06): : 922 - 934
  • [26] Use of a bovine eye lens for observation of HIFU-induced lesions in real-time
    Lafon, Cyril
    Khokhlova, Vera A.
    Kaczkowski, Peter J.
    Bailey, Michael R.
    Sapozhnikov, Oleg A.
    Crum, Lawrence A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (11): : 1731 - 1741
  • [27] Hyperecho in ultrasound images during high-intensity focused ultrasound ablation for hepatocellular carcinomas
    Fukuda, Hiroyuki
    Numata, Kazushi
    Nozaki, Akito
    Kondo, Masaaki
    Morimoto, Manabu
    Tanaka, Katsuaki
    Ito, Ryu
    Ohto, Masao
    Ishibashi, Yoshiharu
    Oshima, Noriyoshi
    Ito, Ayao
    Zhu, Hui
    Wang, Zhi-Biao
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E571 - E575
  • [28] Investigation of HIFU-induced anti-tumor immunity in a murine tumor model
    Hu, Zhenlin
    Yang, Xiao Yi
    Liu, Yunbo
    Morse, Michael A.
    Lyerly, H. Kim
    Clay, Timothy M.
    Zhong, Pei
    THERAPEUTIC ULTRASOUND, 2006, 829 : 241 - +
  • [29] HIFU-induced gene activation in a cell-embedded tissue mimicking phantom
    Yuan, Fang
    Pua, Chris
    Zhong, Pei
    Liu, Yunbo
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 2: BIOMEDICAL AND BIOTECHNOLOGY ENGINEERING, 2008, : 323 - 324
  • [30] Investigation of HIFU-induced anti-tumor immunity in a murine tumor model
    Hu, Zhenlin
    Yang, Xiao Yi
    Liu, Yunbo
    Sankin, Georgy N.
    Pua, Eric C.
    Morse, Michael A.
    Lyerly, H. Kim
    Clay, Timothy M.
    Zhong, Pei
    JOURNAL OF TRANSLATIONAL MEDICINE, 2007, 5 (1)