Evaluation of diffraction errors in precise pulse-echo measurements of ultrasound velocity in chambers with waveguide

被引:3
|
作者
Kazys, R [1 ]
Mazeika, L [1 ]
Barauskas, R [1 ]
Jasiuniene, E [1 ]
Daniulaitis, V [1 ]
机构
[1] Kaunas Univ Technol, Ultrasound Inst, LT-3031 Kaunas, Lithuania
关键词
ultrasonic measurements; ultrasound velocity; diffraction errors; ultrasonic pulse-echo method;
D O I
10.1016/S0041-624X(02)00226-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound velocity measurements in medicine and biology usually are performed using relatively small measurement chambers. When the pulse-echo method is used, the presence of the reflector close to the transducer can cause essential diffraction errors. These errors may be reduced using an additional buffer rod as a waveguide between the transducer and the measurement chamber. The objective of the presented work was analysis of diffraction errors in measurement chambers with a buffer rod. The work was performed in two steps. In the first stage propagation of transient ultrasonic waves in a buffer rod was analysed using an axisymmetric finite element model. This approach enables all dimensions of the measurement chamber and the waveguide to be taken into account, but is less accurate in the time domain. In the second step the absolute values of diffraction errors were evaluated using a mixed analytic-numeric disk shaped transducer diffraction model. In this case only the dimensions of the waveguide and measurement chamber along the wave propagation direction were taken into account. Diffraction errors were calculated by simulating small changes of ultrasound velocity in the liquid under investigation. The simulation performed allowed optimisation of the dimensions of the measurement chamber and a buffer rod thus minimising measurement errors. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:853 / 858
页数:6
相关论文
共 50 条
  • [21] DIFFRACTION EFFECTS AND THEIR ROLE IN PRECISE MEASUREMENTS OF VELOCITY AND ATTENUATION OF ULTRASOUND
    KRASNUSHKIN, PE
    ACUSTICA, 1968, 20 (06): : 343 - +
  • [22] STATISTICAL DIFFRACTION CORRECTION IN PULSE-ECHO ATTENUATION MAPPING
    FINK, M
    CARDOSO, JF
    PERGRALE, J
    ULTRASONIC IMAGING, 1984, 6 (02) : 218 - 219
  • [23] PHYSICAL SOURCES OF REGISTRATION ERRORS IN PULSE-ECHO ULTRASONIC SYSTEMS .1. VELOCITY AND ATTENUATION
    HALLIWEL.M
    MOUNTFOR.RA
    MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (01): : 27 - 32
  • [24] SIDELOBE REDUCTION FOR LIMITED DIFFRACTION PULSE-ECHO SYSTEMS
    LU, JY
    GREENLEAF, JF
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (06) : 735 - 746
  • [25] A broadband wavelet implementation for rapid ultrasound pulse-echo time-of-flight measurements
    Sturtevant, Blake T.
    Velisavljevic, Nenad
    Sinha, Dipen N.
    Kono, Yoshio
    Pantea, Cristian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (07):
  • [26] Evaluation of the Transmission Line Model for Couplant Layer Corrections in Pulse-Echo Measurements
    Sturtevant, Blake T.
    Pantea, Cristian
    Sinha, Dipen N.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (05) : 943 - 953
  • [27] DISTORTION CHARACTERIZATION FOR NONNORMAL INCIDENCE IN PULSE-ECHO ULTRASOUND
    OROFINO, DP
    PEDERSEN, PC
    IEEE 1989 ULTRASONICS SYMPOSIUM : PROCEEDINGS, VOLS 1 AND 2, 1989, : 1073 - 1076
  • [28] IMPROVEMENT IN PULSE-ECHO TECHNIQUE FOR ULTRASONIC ATTENUATION MEASUREMENTS
    TRIPATHI, RC
    GUPTA, AK
    VERMA, GS
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 53 (04): : 1102 - 1106
  • [29] ATTENUATION MEASUREMENTS USING PULSE-ECHO AB METHOD
    LYNNWORTH, LC
    MATERIALS EVALUATION, 1971, 29 (02) : A27 - +
  • [30] DIFFRACTION CORRECTION METHODS FOR PULSE-ECHO ACOUSTIC ATTENUATION ESTIMATION
    CESPEDES, I
    OPHIR, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07): : 707 - 717