Indoor PM2.5 removal efficiency of two different non-thermal plasma systems

被引:13
|
作者
Hernandez-Diaz, D. [1 ]
Martos-Ferreira, D. [2 ]
Hernandez-Abad, V. [3 ]
Villar-Ribera, R. [4 ]
Tarres, Q. [5 ]
Rojas-Sola, J. I. [6 ]
机构
[1] Univ Politecn Cataluna, Dept Engn Graph & Design, Serra Hunter Programme, TR5 Campus Terrassa, Terrassa 08222, Spain
[2] Salesian Univ, Sch Sarria, Dept Elect, Passeig Sant Joan Bosco 74, Barcelona 08017, Spain
[3] Univ Politecn Cataluna, Dept Engn Graph & Design, TR5 Campus Terrassa, Terrassa 08222, Spain
[4] Univ Politecn Cataluna, Dept Engn Graph & Design, Campus Manresa, Manresa 08242, Spain
[5] Univ Girona, Dept Chem Engn, LEPAMAP Grp, Girona 17003, Spain
[6] Univ Jaen, Dept Engn Graph Design & Projects, Jaen, Spain
关键词
Non-thermal plasma (NTP); Corona discharge; Dielectric barrier discharge (DBD); Fine particulate matter (PM2.5); Ozone (O-3); Indoor air quality (IAQ);
D O I
10.1016/j.jenvman.2020.111515
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of non-thermal plasma (NTP) generators in air processing systems and their duct networks to improve indoor air quality (IAQ) has grown considerably in recent years. This paper reviews the advantages and disadvantages of NTP generators for IAQ improvement in biological, chemical and particulate pollutant terms. Also, it assesses and compares the ability of a multipin corona discharge (MPCD) and a dielectric barrier discharge (DBD) generator to reduce the concentration of fine particulate matter (PM2.5) in recycled, unfiltered air in a refrigeration chamber. The MPCD generator was found to have a higher PM2.5 removal efficiency; also, it was faster in removing pollutants, used less energy, and produced much less ozone. The fact that the MPCD generator performed better was seemingly the result of its increased ion production mainly. NTP generators, however, cannot match air filtration media purifiers in this respect as the latter are much more effective in removing particles. Besides, NTP-based air purifying technology continues to be subject to a major drawback, namely: the formation of ozone as a by-product. In any case, the ozone generation was uncorrelated to ion emission when using different technologies.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Comparison Study between Indoor and Outdoor Chemical Composition of PM2.5 in Two Italian Areas
    Tofful, Luca
    Perrino, Cinzia
    Canepari, Silvia
    ATMOSPHERE, 2020, 11 (04)
  • [42] Field Tests of Indoor Air Cleaners for Removal of PM2.5 and PM10 in Elementary School Classrooms in Seoul, Korea
    Han, Bangwoo
    Hong, Keejung
    Shin, Dongho
    Kim, Hak-Joon
    Kim, Yong-Jin
    Kim, Sang Bok
    Kim, Sangwoo
    Hwang, Cheong-Ha
    Noh, Kwang-Chul
    AEROSOL AND AIR QUALITY RESEARCH, 2022, 22 (04)
  • [43] A mathematical model for predicting indoor PM2.5 concentration considering uneven mixing and fractional efficiency of a filter
    Liu, Lianhua
    Xiang, Bo
    Si, Pengfei
    Shi, Lijun
    INDOOR AND BUILT ENVIRONMENT, 2024, 33 (03) : 451 - 464
  • [44] Overall collection efficiency of a plate-wire electrostatic precipitator operating on the removal of PM2.5
    Falaguasta, M. C. R.
    Steffens, J.
    Valdes, E. E.
    Coury, J. R.
    LATIN AMERICAN APPLIED RESEARCH, 2008, 38 (02) : 179 - 186
  • [45] Indoor PM2.5 and building energy consumption in nine typical residential neighborhoods in Nanjing under different ventilation strategies caused by traffic-related PM2.5 dispersion
    Wang H.
    Guo X.
    Yang J.
    Gao Z.
    Zhang M.
    Xu F.
    Journal of Building Engineering, 2024, 95
  • [46] Decomposition of indoor VOC pollutants using non-thermal plasma with gas recycling
    Santos, Christian Ariane
    Nguyen Hoang Phuong
    Park, Mi Jeong
    Kim, Sang Bum
    Jo, Young Min
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2020, 37 (01) : 120 - 129
  • [47] Decomposition of indoor VOC pollutants using non-thermal plasma with gas recycling
    Christian Ariane Santos
    Nguyen Hoang Phuong
    Mi Jeong Park
    Sang Bum Kim
    Young Min Jo
    Korean Journal of Chemical Engineering, 2020, 37 : 120 - 129
  • [48] Assessment on the Personal Exposure Risk Associated With Real-Time Indoor PM2.5 in Different Microenvironments
    Dai, Shuiping
    He, Yuhang
    Zeng, Ni
    Wang, Zhenglu
    INDOOR AIR, 2024, 2024
  • [49] Applicability of ambient and indoor monitoring for personal exposure assessment to PM2.5 from different emission sources
    Kimmo, K
    Rufus, E
    Patrick, M
    Matti, J
    EPIDEMIOLOGY, 2002, 13 (04) : S236 - S236
  • [50] Deposit removal in EGR cooler and effectiveness improvement by non-thermal plasma reactor with different gas sources
    Li, Xiaohua
    Li, Weijun
    Cai, Yixi
    Shi, Yunxi
    Zheng, Yi
    Xu, Hui
    Pu, Xiaoyu
    Gu, Linbo
    APPLIED THERMAL ENGINEERING, 2017, 111 : 694 - 702