The Effect of Laser Treatment on the Morphology of Graphene/CdTe X-Ray and γ-Ray Detectors

被引:0
|
作者
Maslyanchuk, Olena [1 ]
Strebezhev, Viktor [1 ]
Fochuk, Petro [1 ]
Fodchuk, Ihor [1 ]
Sorokatyi, Mykola [1 ]
Bolotnikov, Aleksey [2 ]
James, R. B. [3 ]
机构
[1] Yury Fedkovych Chernivtsi Natl Univ, UA-58012 Chernovtsy, Ukraine
[2] Brookhaven Natl Lab, Upton, NY 11973 USA
[3] Savannah River Natl Lab, Aiken, SC 29808 USA
关键词
CdTe detectors; Graphene; CdTe Schottky diode; laser treatment;
D O I
10.1117/12.2570634
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Peculiarities of morphology and electric properties of X-ray and gamma-ray detectors developed by graphene deposition onto commercially available (111) oriented CdTe:Cl wafers has been investigated. Laser treatment of graphene contact using millisecond YAG-laser with an energy density of 0.1-4.5 J/cm(2) has been carried out in order to modify and improve their structure and phase state.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The Effect of Oblique X-Ray Incidence on the Design of X-Ray Detectors for Digital Tomosynthesis
    Acciavatti, R.
    Maidment, A.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [22] APPLICATION OF GAAS AND CDTE PHOTOCONDUCTOR DETECTORS TO X-RAY FLASH RADIOGRAPHY
    MATHY, F
    CUZIN, M
    GAGELIN, JJ
    MERMET, R
    PIAGET, B
    RUSTIQUE, J
    VERGER, L
    HAUDUCOEUR, A
    NICOLAS, P
    LEDAIN, L
    HYVERNAGE, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 615 - 618
  • [23] Comparison of the X-Ray Performance of Small Pixel CdTe and CZT Detectors
    Wilson, Matthew D.
    Barnes, Paul
    Cernik, Robert C.
    Hansson, Conny C. T.
    Jacques, Simon
    Jones, Lawrence L.
    Seller, Paul
    Sellin, Paul J.
    Sochi, Taha
    Veale, Matthew C.
    Veeramani, Peruami
    Withers, Philip J.
    Youd, Christopher P.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3942 - 3946
  • [24] A diffraction effect in X-ray area detectors
    Gollwitzer, C. (christian.gollwitzer@ptb.de), 1600, International Union of Crystallography, 5 Abbey Road, Chester, CH1 2HU, United Kingdom (47):
  • [25] A diffraction effect in X-ray area detectors
    Gollwitzer, Christian
    Krumrey, Michael
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 378 - 383
  • [26] Epitaxial GaAs X-ray detectors for X-ray astrophysics
    Bavdaz, M
    Owens, A
    Peacock, A
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 451 - 456
  • [27] Characterization and diagnostics of fast X-ray imaging detectors for X-ray free electron laser sources
    Castoldi, Andrea
    Guazzoni, Chiara
    Mezza, Davide
    Carraresi, Luca
    Taccetti, Francesco
    ADVANCES IN X-RAY FREE-ELECTRON LASERS: RADIATION SCHEMES, X-RAY OPTICS, AND INSTRUMENTATION, 2011, 8078
  • [28] Characteristics and Stability of Diode Type CdTe-based X-Ray and Gamma-Ray Detectors
    Gnatyuk, V. A.
    Vlasenko, O. I.
    Aoki, T.
    Koike, A.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [29] A System for the Characterization and Testing of CdZnTe/CdTe Pixel Detectors for X-ray and Gamma-ray Imaging
    Arodzero, Anatoli
    Barber, William C.
    Damron, Matthew Q.
    Hartsough, Neal E.
    Iwanczyk, Jan S.
    Malakhov, Nail
    Nygard, Einar
    Moraes, Danielle
    Weilhammer, Peter
    Jarron, Pierre
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3638 - 3642
  • [30] X-ray detectors for astrophysics
    Remillard, RA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 285 - 291